Unigreen 22, 16, 11, 32 manual Noise Level of the Machine, Standards of Reference

Page 8

3.2NOISE LEVEL OF THE MACHINE

Use earmuffs to protect your ears when using the machine,

Sprayers that are equipped with just a pump and hydraulic plant ACOUSTIC POWER LEVEL emitted by the machine: 106,0 dBA ACOUSTIC PRESSURE LEVEL AT THE OPERATOR’S POSITION emitted by the machine: 91,4 dBA

Sprayers that are equipped of air sleeve (VENTO)

ACOUSTIC POWER LEVEL emitted by the machine with impeller Vento: 114,8 dBA

ACOUSTIC PRESSURE LEVEL AT THE OPERATOR’S POSITION emitted by the machine with impeller Vento: 97,6 dBA

Readings taken in accordance with the following standards: Machines Directive 98/37/CE (89/392 CE Dir. re-codified).

Legislative Decree D.Lgs. n°292 of the 4th of September 2002 concerning the environmental acoustic emission of machines and equipment for use outdoors. Italian Legs. Decree no. 195 of 10/4/2006 on the subject of the protection of workers against the risks deriving from exposure to chemical, physical and biological agents. UNI EN 1553:2001 appendix D

3.3STANDARDS OF REFERENCE:

-MACHINES DIRECTIVE 98/37/CEE (89/392 CE Dir. re-codified).

-Directive 86/188/CEE: risks deriving from exposure to noise (implemented in Italy by Legislative Decree D.L 277/1991)

-DPR 547/1955: Regulations for the prevention of accidents and hygiene at work.

-Legislative Decree D.Lgs. n°292 of the 4th of September 2002 concerning the environmental acoustic emission of machines and equipment for use outdoors. -UNI EN ISO 12100-1/Apr.2005 : Machinery safety - Fundamental concepts, general design principles - Part 1: basic terminology, methodology

-UNI EN ISO 12100-2/Apr.2005 : Machinery safety - Fundamental concepts,

general design principles - Part 2: Technical principles

-UNI EN 294/July 1993: Machinery safety, safe distances to avoid reaching hazardous areas with upper limbs.

-UNI EN 349/June 1994: Machinery safety, minimum spaces to prevent crushing of body parts

-UNI EN 907/Nov.1998: Agricultural and forestry machinery - Sprayers and spreaders of liquid fertilizers - Safety.

-UNI EN 954-1/Dec. 1998 : Machinery safety - Fundamental concepts, general design principles

-UNI EN 982/July 1997: Machinery safety. Safety requisites relevant to systems and their components for hydraulic and pneumatic transmissions. Hydraulics. -UNI EN ISO 4254-1/June 2006: Agricultural machines - Safety - Part 1: General requisites

-ISO 11684/1995: Pictograms - general principles.

4USER’S INSTRUCTIONS

4.1DESCRIPTION OF THE MACHINE

The sprayers are made of a structural steel frame and a polyester tank reinforced with fibreglass or high-density polyethylene.

The frame is painted with special fired epoxy paints or, depending on the versions, hot galvanised. The tank is easy to empty and this makes it possible to use the machine even on hillsides.

The pumps are generally diaphragm pumps but in some cases fitted with pistons.

The accessories that can be used to complete the sprayer include: lifting devices, self-levelling devices, mechanical or hydraulic herbicide booms, jets and nozzles and this makes the UNIGREEN sprayer a highly qualified and efficient piece of equipment.

8unigreen

Image 8
Contents USE and Maintenance Manual 10/2007Summary Hand Lances Hose Reel Maintenance Guarantee Composition of the ManualImproper use Product Responsibility Unigreen spa is not responsible ifKey to the symbols Using Chemical Products Intended USEProhibited USE RecommendationsMachines Designed to be Used only with Clean Water Characteristics and SpecificationsWeather Conditions Driving on the RoadUSER’S Instructions Description of the Machine Noise Level of the MachineStandards of Reference Work Stations Hand Washing TanksPreliminary Checks Transporting and Moving the MachineStandard Version Elevator Coupling Towed Sprayers ParkingTractor Coupling Parking Foot Wheel Spacing AdjustmentHook Version Homologated Hydraulic Connection to the Distributors Cardan ShaftPump Suction FilterPressure Regulator Components of the Pressure RegulatorControl box for Ergo and Remo electrical regulators General InstructionsSpraying Computer Optional Filling the Tank MixingManual Premixing Premixer on Cover OptionalTOP-Mix S41 Premixer on Hopper with TIN Washer OptionalHOW to USE the LP83 Incorporator Washing with Full Tank Optional Washing the SprayerCircuit Washer and Tank Washer Horizontal Booms for Herbacious Cultivations Hydraulic Herbicide BoomsExceed a height of 4 meters Indipendent Hydraulic PlantVariable Geometry AIR-ASSISTED BoomsSELF-LEVELING Devices Lifting Distrubution with Herbicide BoomDescription of Type of Jets Description of Type of NozzlesUseful Information =600xQHose Reel MarkerHand Lances Maintenance Programmed Maintenance TAB. NRoutine Maintenance Extraordinary MaintenancePutting Back Into Service After Winter Layup Demolition and DisposalMaterials for Demolition Electrical and Electronic Apparatus Waste EeawUnigreen TAB.1 Characteristics Nozzles ISO Arancio Orange Verde Green Giallo Yellow BLU Blue Rosso REDTAB.2 Characteristics Nozzles Conical ISO Rosso RED Marrone BrownTAB.3-4 Capacity Hand Lances 2500 TAB.5-6 Spraying Tables50 h 300 h Table of Programmed Maintenance OperationPROBLEMS, Causes and Solutions TAB.12A Allowed Fittings TAB aTAB b TAB.12B Allowed FittingsIlpolietilene Rotazionale Member of the group