Intel S5000XAL manual Revision, Intel order number D31979-007

Page 1

Intel® Server Board S5000PAL / S5000XAL

Technical Product Specification

Intel order number: D31979-007

Revision 1.4

May 2007

Enterprise Platforms and Services Division - Marketing

ii

Revision 1.4

 

Intel order number: D31979-007

Image 1
Contents Intel order number D31979-007 RevisionIntel Server Board S5000PAL / S5000XAL TPSRevision History IiiDate Revision Modifications Number Disclaimers Intel Server Board S5000PAL / S5000XAL TPS DisclaimersTable of Contents Light Guided Diagnostics Jumper Block SettingsPower and Environmental Specifications 105 101108 111Viii Revision Intel order number D31979-007 List of Figures Intel Server Board S5000PAL / S5000XAL TPSIntel Server Board S5000PAL / S5000XAL TPS List of Tables List of TablesList of Tables Intel Server Board S5000PAL / S5000XAL TPS Page Server Board Use Disclaimer Chapter OutlineIntroduction Intel Server Board S5000PAL / S5000XAL TPS 12Revision Intel order number D31979-007Feature Description Intel Server Board S5000PAL / S5000XAL Feature SetIntel Server Board S5000PAL / S5000XAL TPS Product Overview Product Overview Intel Server Board S5000PAL / S5000XAL TPS Server Board Layout14Revision Intel order number D31979-007 Connector and Component Locations Sata LDM Light Guided Diagnostic LED LocationsExternal I/O Connector Locations Server Board Mechanical Drawings 40.39 PCI BKT Drop Down TP02294 10.16 16.51 113.13 199.21 285.75 182.83 274.32 298.51 Functional Architecture System Bus Interface Intel 5000P and 5000X Memory Controller Hubs MCHProcessor Support Common Enabling Kit CEK Design Support Processor Population RulesProcessor Support Matrix 26Revision Intel order number D31979-007CEK Processor Mounting Memory Sub-systemSupported Memory Memory Rasum FeaturesiMinimum Non-Mirrored Mode Configuration Dimm Population Rules and Supported Dimm ConfigurationsBranch Channel B Channel a Recommended Four Dimm Configuration Non-mirrored mode memory upgrades32Revision Intel order number D31979-007 Single Branch Mode Sparing Dimm ConfigurationSnoop Filter 5000X MCH only ESB-2 IO Controller1.1 PCI32 32-bit, 33-MHz PCI Bus Segment PCI Sub-systemPXA 64-bit, 133MHz PCI-X* Bus Segment 1.3 PE1 One x4 PCI Express* Bus Segment1.6 PE6, PE7 Two x4 PCI Express* Bus Segments 1.5 PE4, PE5 Two x4 PCI Express* Bus SegmentsPCI Riser Slots Intel Embedded Server RAID Technology II Support Serial ATA Support36Revision Intel order number D31979-007 Parallel ATA Pata Support Video SupportUSB 2.0 Support Intel Embedded Server RAID Technology Option ROMVideo Memory Interface Video ModesDual Video Video ModesIntel I/O Acceleration Technology Network Interface Controller NICMAC Address Definition NIC2 Status LEDSuper I/O Pin Signal Name Serial Port a Header Pin-outSerial Ports Serial a Header Pin-outRJ45 Signal Abbreviation Pins What happens at system reset…Floppy Disk Controller Keyboard and Mouse SupportSystem Health Support Wake-up Control42Revision Intel order number D31979-007 Platform Management Board Connector Matrix Board Connector Information44Revision Intel order number D31979-007 Power Connector Pin-out J3K3 Power ConnectorsPower Connector Pin-out J3K4 Power Supply Signal Connector Pin-out J1K1Intel RMM Connector Pin-out J1C5 Intel Remote Management Module RMM ConnectorPin Signal Name System Management HeadersPin Intel RMM NIC Module Connector Pin-out J1B2 Intel RMM NIC Connector3 LCP/AUX Ipmb Header Riser Card SlotsIpmb Header Pin Side a PCI Spec Signal Pin Side B PCI Spec SignalPin-Side B PCI Spec Signal Pin-Side a PCI Spec Signal Full-height Riser Slot Pin-out J4F150Revision Intel order number D31979-007 Pin-Side B PCI Spec Signal Pin-Side a PAR64 52Revision Intel order number D31979-007Bridge Board Connector SSI Control Panel ConnectorFront Panel SSI Standard 24-pin Connector Pin-out J3H2 Pin Bridgeboard Connector Pin-out J4G154Revision Intel order number D31979-007 VGA Connector I/O Connector Pin-out DefinitionNIC Connectors VGA Connector Pin-out J6A1Intel I/O Expansion Module Connector IDE ConnectorPin IDE Connector Pin-out J3G1 56Revision Intel order number D31979-007Sata Connector Pin-out J1H1, J1G2, J1G1, J1F2, J1E3 Sata ConnectorsKeyboard and Mouse Connector Serial Port ConnectorsExternal USB Connector Pin-out J5A1, J6A2 USB 2.0 ConnectorsInternal USB Connector Pin-out J1J1 Pin Signal Name Type Description SSI Fan Connector Pin-out J9K1,J5K1,J3K1,J3K2,J7A2,J7A1Fan Headers 60Revision Intel order number D31979-007Recovery Jumpers J1D1, J1D2, J1D3 Recovery Jumper BlocksJumper Name Pins What happens at system reset… BMC Force Update Procedure Cmos Clear and Password Reset Usage Procedure62Revision Intel order number D31979-007 Bios Select Jumper J3H1 Bios Select JumperExternal RJ45 Serial Port Jumper Block 5-Volt Standby LED Light Guided Diagnostics66Revision Intel order number D31979-007 System ID LED and System Status LEDColor State Criticality Description System Status LED BMC InitializationProcessor Fault LED Dimm Fault LEDsPost Code Diagnostic LEDs 70Revision Intel order number D31979-007 Server Board Design SpecificationsProcessor Power Support Server Board Power RequirementsTDP Power Max Tcase Icc MAX 130 W 70º C 150 a Load Ratings Turn On No Load OperationNo load operating range 72Revision Intel order number D31979-007Standby Outputs GroundingRemote Sense Voltage RegulationDynamic Loading Common Mode NoiseCapacitive Loading Closed-Loop StabilitySoft Starting Ripple / NoiseTiming Requirements Ripple and NoiseOut 10% V out MIN MAX Units 78Revision Intel order number D31979-007 Residual Voltage Immunity in Standby ModeAustralia / New Zealand AS/NZS 3548 Emissions Product Safety & Electromagnetic EMC ComplianceReference Example FCC Verification Statement USA Electromagnetic Compatibility NoticesICES-003 Canada Europe CE Declaration of ConformityRRL Korea Bsmi TaiwanEnglish translation of the notice above Product Ecology Compliance Japan Recycling Other MarkingsCompliance Compliance Reference Description Marking Example 84Revision Intel order number D31979-007 Appendix a Integration and Usage Tipsƒ Sensor Type ƒ Assertion / De-assertion Enablesƒ Event / Reading Type ƒ Event Offset/Triggersƒ Criticality ƒ Default Hysteresisƒ Standby 86Revision Intel order number D31979-007Value Bility Type NMI STB Revision Revision Intel order number D31979-007 Revision Acpi Bios EPS PCIe Link1 Revision Dimm A2 Dimm D2 ECC B01 Dimm 100 Revision Intel order number D31979-007LEDs Red Green Post Progress Code LED Example102Revision Intel order number D31979-007 Revision 103 Intel order number D31979-007 Pre-EFI Initialization Module Peim / Recovery Runtime Phase / EFI Operating System Boot104Revision Intel order number D31979-007 Error Code Error Message Response Post Error Messages and HandlingRevision Intel order number D31979-007 105 ROM 106Revision Intel order number D31979-007Post Error Beep Codes Post Error Beep CodesBMC Beep Codes Revision 107 Intel order number D31979-007Appendix E Supported Intel Server Chassis Page Slim-Line Optical Drive Bay Revision 111 Intel order number D31979-007 Intel Server Board S5000PAL / S5000XAL TPS GlossaryTerm Definition 112Revision Intel order number D31979-007 Glossary Intel Server Board S5000PAL / S5000XAL TPSRevision 113 Intel order number D31979-007 114Revision Intel order number D31979-007 Reference Documents