Intel S5000XAL manual Memory Rasum Featuresi, Supported Memory

Page 27

Functional Architecture

Intel® Server Board S5000PAL / S5000XAL TPS

To boot the system, the system BIOS on the server board uses a dedicated I2C bus to retrieve DIMM information needed to program the MCH memory registers. The following table provides the I2C addresses for each DIMM slot.

Table 2. I2C Addresses for Memory Module SMB

Device

Address

DIMM A1

0xA0

 

 

DIMM A2

0xA2

 

 

DIMM B1

0xA0

 

 

DIMM B2

0xA2

 

 

DIMM C1

0xA0

 

 

DIMM C2

0xA2

 

 

DIMM D1

0xA0

 

 

DIMM D2

0xA2

 

 

3.1.3.1Memory RASUM Featuresi

The MCH supports several memory RASUM (Reliability, Availability, Serviceability, Usability, and Manageability) features. These features include the Intel® x4 Single Device Data Correction (Intel® x4 SDDC) for memory error detection and correction, Memory Scrubbing, Retry on Correctable Errors, Memory Built In Self Test, DIMM Sparing, and Memory Mirroring. See the Intel® S5000 Series Chipsets Server Board Family Datasheet for more information describing these features.

3.1.3.2Supported Memory

The server board supports up to eight DDR2-533 or DDR2-667 Fully Buffered DIMMs (FBD memory). The following tables show the maximum memory configurations supported using the specified memory technology.

Table 3. Maximum 8 DIMM System Memory Configuration – x8 Single Rank

DRAM Technology x8

Maximum Capacity

Maximum Capacity

Single Rank

Mirrored Mode

Non-Mirrored Mode

256 Mb

1 GB

2 GB

512 Mb

2 GB

4 GB

1024 Mb

4 GB

8 GB

2048 Mb

8 GB

16 GB

Table 4. Maximum 8 DIMM System Memory Configuration – x4 Dual Rank

DRAM Technology x4

Maximum Capacity

Maximum Capacity

Dual Rank

Mirrored Mode

Non-Mirrored Mode

256 Mb

4 GB

8 GB

512 Mb

8 GB

16 GB

1024 Mb

16 GB

32 GB

2048 Mb

16 GB

32 GB

Note: DDR2 DIMMs that are not fully buffered are NOT supported on this server board. See the Intel® Server Board S5000PAL / S5000XAL Tested Memory List for a complete list of supported memory for this server board.

28Revision 1.4

Intel order number: D31979-007

Image 27
Contents Intel order number D31979-007 RevisionIii Intel Server Board S5000PAL / S5000XAL TPSRevision HistoryDate Revision Modifications Number Disclaimers Intel Server Board S5000PAL / S5000XAL TPS DisclaimersTable of Contents Jumper Block Settings Light Guided DiagnosticsPower and Environmental Specifications 111 101105 108Viii Revision Intel order number D31979-007 List of Figures Intel Server Board S5000PAL / S5000XAL TPSIntel Server Board S5000PAL / S5000XAL TPS List of Tables List of TablesList of Tables Intel Server Board S5000PAL / S5000XAL TPS Page 12Revision Intel order number D31979-007 Chapter OutlineServer Board Use Disclaimer Introduction Intel Server Board S5000PAL / S5000XAL TPSIntel Server Board S5000PAL / S5000XAL Feature Set Feature DescriptionIntel Server Board S5000PAL / S5000XAL TPS Product Overview Server Board Layout Product Overview Intel Server Board S5000PAL / S5000XAL TPS14Revision Intel order number D31979-007 Connector and Component Locations Sata LDM Light Guided Diagnostic LED LocationsExternal I/O Connector Locations Server Board Mechanical Drawings 40.39 PCI BKT Drop Down TP02294 10.16 16.51 113.13 199.21 285.75 182.83 274.32 298.51 Functional Architecture Intel 5000P and 5000X Memory Controller Hubs MCH System Bus InterfaceProcessor Support 26Revision Intel order number D31979-007 Processor Population RulesCommon Enabling Kit CEK Design Support Processor Support MatrixCEK Processor Mounting Memory Sub-systemSupported Memory Memory Rasum FeaturesiMinimum Non-Mirrored Mode Configuration Dimm Population Rules and Supported Dimm ConfigurationsBranch Channel B Channel a Recommended Four Dimm Configuration Non-mirrored mode memory upgrades32Revision Intel order number D31979-007 Single Branch Mode Sparing Dimm ConfigurationSnoop Filter 5000X MCH only ESB-2 IO Controller1.3 PE1 One x4 PCI Express* Bus Segment PCI Sub-system1.1 PCI32 32-bit, 33-MHz PCI Bus Segment PXA 64-bit, 133MHz PCI-X* Bus Segment1.5 PE4, PE5 Two x4 PCI Express* Bus Segments 1.6 PE6, PE7 Two x4 PCI Express* Bus SegmentsPCI Riser Slots Serial ATA Support Intel Embedded Server RAID Technology II Support36Revision Intel order number D31979-007 Intel Embedded Server RAID Technology Option ROM Video SupportParallel ATA Pata Support USB 2.0 SupportVideo Modes Video ModesVideo Memory Interface Dual VideoNIC2 Status LED Network Interface Controller NICIntel I/O Acceleration Technology MAC Address DefinitionSerial a Header Pin-out Pin Signal Name Serial Port a Header Pin-outSuper I/O Serial PortsKeyboard and Mouse Support Pins What happens at system reset…RJ45 Signal Abbreviation Floppy Disk ControllerWake-up Control System Health Support42Revision Intel order number D31979-007 Platform Management Board Connector Information Board Connector Matrix44Revision Intel order number D31979-007 Power Supply Signal Connector Pin-out J1K1 Power ConnectorsPower Connector Pin-out J3K3 Power Connector Pin-out J3K4System Management Headers Intel Remote Management Module RMM ConnectorIntel RMM Connector Pin-out J1C5 Pin Signal NamePin Intel RMM NIC Module Connector Pin-out J1B2 Intel RMM NIC ConnectorRiser Card Slots 3 LCP/AUX Ipmb HeaderIpmb Header Full-height Riser Slot Pin-out J4F1 Pin Side B PCI Spec SignalPin Side a PCI Spec Signal Pin-Side B PCI Spec Signal Pin-Side a PCI Spec Signal50Revision Intel order number D31979-007 Pin-Side B PCI Spec Signal Pin-Side a PAR64 52Revision Intel order number D31979-007Pin Bridgeboard Connector Pin-out J4G1 SSI Control Panel ConnectorBridge Board Connector Front Panel SSI Standard 24-pin Connector Pin-out J3H254Revision Intel order number D31979-007 VGA Connector Pin-out J6A1 I/O Connector Pin-out DefinitionVGA Connector NIC Connectors56Revision Intel order number D31979-007 IDE ConnectorIntel I/O Expansion Module Connector Pin IDE Connector Pin-out J3G1Sata Connector Pin-out J1H1, J1G2, J1G1, J1F2, J1E3 Sata ConnectorsKeyboard and Mouse Connector Serial Port ConnectorsUSB 2.0 Connectors External USB Connector Pin-out J5A1, J6A2Internal USB Connector Pin-out J1J1 60Revision Intel order number D31979-007 SSI Fan Connector Pin-out J9K1,J5K1,J3K1,J3K2,J7A2,J7A1Pin Signal Name Type Description Fan HeadersRecovery Jumper Blocks Recovery Jumpers J1D1, J1D2, J1D3Jumper Name Pins What happens at system reset… Cmos Clear and Password Reset Usage Procedure BMC Force Update Procedure62Revision Intel order number D31979-007 Bios Select Jumper J3H1 Bios Select JumperExternal RJ45 Serial Port Jumper Block 5-Volt Standby LED Light Guided Diagnostics66Revision Intel order number D31979-007 System ID LED and System Status LEDColor State Criticality Description System Status LED BMC InitializationProcessor Fault LED Dimm Fault LEDsPost Code Diagnostic LEDs 70Revision Intel order number D31979-007 Server Board Design SpecificationsServer Board Power Requirements Processor Power SupportTDP Power Max Tcase Icc MAX 130 W 70º C 150 a 72Revision Intel order number D31979-007 Turn On No Load OperationLoad Ratings No load operating rangeVoltage Regulation GroundingStandby Outputs Remote SenseClosed-Loop Stability Common Mode NoiseDynamic Loading Capacitive LoadingRipple and Noise Ripple / NoiseSoft Starting Timing RequirementsOut 10% V out MIN MAX Units 78Revision Intel order number D31979-007 Residual Voltage Immunity in Standby ModeProduct Safety & Electromagnetic EMC Compliance Australia / New Zealand AS/NZS 3548 EmissionsReference Example Europe CE Declaration of Conformity Electromagnetic Compatibility NoticesFCC Verification Statement USA ICES-003 CanadaBsmi Taiwan RRL KoreaEnglish translation of the notice above Product Ecology Compliance Other Markings Japan RecyclingCompliance Compliance Reference Description Marking Example 84Revision Intel order number D31979-007 Appendix a Integration and Usage Tipsƒ Event Offset/Triggers ƒ Assertion / De-assertion Enablesƒ Sensor Type ƒ Event / Reading Type86Revision Intel order number D31979-007 ƒ Default Hysteresisƒ Criticality ƒ StandbyValue Bility Type NMI STB Revision Revision Intel order number D31979-007 Revision Acpi Bios EPS PCIe Link1 Revision Dimm A2 Dimm D2 ECC B01 Dimm 100 Revision Intel order number D31979-007LEDs Red Green Post Progress Code LED Example102Revision Intel order number D31979-007 Revision 103 Intel order number D31979-007 Runtime Phase / EFI Operating System Boot Pre-EFI Initialization Module Peim / Recovery104Revision Intel order number D31979-007 Post Error Messages and Handling Error Code Error Message ResponseRevision Intel order number D31979-007 105 ROM 106Revision Intel order number D31979-007Revision 107 Intel order number D31979-007 Post Error Beep CodesPost Error Beep Codes BMC Beep CodesAppendix E Supported Intel Server Chassis Page Slim-Line Optical Drive Bay Intel Server Board S5000PAL / S5000XAL TPS Glossary Revision 111 Intel order number D31979-007Term Definition 112Revision Intel order number D31979-007 Glossary Intel Server Board S5000PAL / S5000XAL TPSRevision 113 Intel order number D31979-007 114Revision Intel order number D31979-007 Reference Documents