Intel S5000XAL manual Post Error Messages and Handling, Revision Intel order number D31979-007 105

Page 104

Intel® Server Board S5000PAL / S5000XAL TPS Appendix D: POST Error Messages and Handling

Appendix D: POST Error Messages and Handling

Whenever possible, the BIOS will output the current boot progress codes on the video screen. Progress codes are 32-bit quantities plus optional data. The 32-bit numbers include class, subclass, and operation information. The class and subclass fields point to the type of hardware that is being initialized. The operation field represents the specific initialization activity. Based on the data bit availability to display progress codes, a progress code can be customized to fit the data width. The higher the data bit, the higher the granularity of information that can be sent on the progress port. The progress codes may be reported by the system BIOS or option ROMs.

The Response section in the following table is divided into two types:

Pause: The message is displayed in the Error Manager screen, an error is logged to the SEL, and user input is required to continue. The user can take immediate corrective action or choose to continue booting.

Halt: The message is displayed in the Error Manager screen, an error is logged to the SEL, and the system cannot boot unless the error is resolved. The user needs to replace the faulty part and restart the system.

Table 47. POST Error Messages and Handling

 

Error Code

Error Message

Response

 

 

004C

Keyboard / interface error

Pause

 

 

 

 

 

 

 

0012

CMOS date / time not set

Pause

 

 

 

 

 

 

 

5220

Configuration cleared by jumper

Pause

 

 

 

 

 

 

 

5221

Passwords cleared by jumper

Pause

 

 

 

 

 

 

 

5223

Configuration default loaded

Pause

 

 

 

 

 

 

 

0048

Password check failed

Halt

 

 

 

 

 

 

 

0141

PCI resource conflict

Pause

 

 

 

 

 

 

 

0146

Insufficient memory to shadow PCI ROM

Pause

 

 

 

 

 

 

 

8110

Processor 01 internal error (IERR) on last boot

Pause

 

 

 

 

 

 

 

8111

Processor 02 internal error (IERR) on last boot

Pause

 

 

 

 

 

 

 

8120

Processor 01 thermal trip error on last boot

Pause

 

 

 

 

 

 

 

8121

Processor 02 thermal trip error on last boot

Pause

 

 

 

 

 

 

 

8130

Processor 01 disabled

Pause

 

 

 

 

 

 

 

8131

Processor 02 disabled

Pause

 

 

 

 

 

 

 

8160

Processor 01 unable to apply BIOS update

Pause

 

 

 

 

 

 

 

8161

Processor 02 unable to apply BIOS update

Pause

 

 

 

 

 

 

 

8190

Watchdog timer failed on last boot

Pause

 

 

 

 

 

 

 

8198

Operating system boot watchdog timer expired on last boot

Pause

 

 

 

 

 

 

 

0192

L3 cache size mismatch

Halt

 

 

 

 

 

 

 

0194

CPUID, processor family are different

Halt

 

 

 

 

 

 

 

0195

Front side bus mismatch

Pause

 

 

 

 

 

 

 

0197

Processor speeds mismatched

Pause

 

 

 

 

 

 

 

8300

Baseboard management controller failed self-test

Pause

 

 

 

 

 

 

 

8306

Front panel controller locked

Pause

 

 

 

 

 

 

 

8305

Hot swap controller failed

Pause

 

 

 

 

 

 

 

84F2

Baseboard management controller failed to respond

Pause

 

 

 

 

 

 

 

84F3

Baseboard management controller in update mode

Pause

 

 

 

 

 

 

 

84F4

Sensor data record empty

Pause

 

 

 

 

 

 

 

 

 

 

 

 

Revision 1.4

Intel order number: D31979-007

105

 

 

 

 

 

Image 104
Contents Revision Intel order number D31979-007Date Revision Modifications Number IiiIntel Server Board S5000PAL / S5000XAL TPSRevision History Disclaimers Disclaimers Intel Server Board S5000PAL / S5000XAL TPSTable of Contents Power and Environmental Specifications Jumper Block SettingsLight Guided Diagnostics 101 105108 111List of Figures Intel Server Board S5000PAL / S5000XAL TPS Viii Revision Intel order number D31979-007List of Tables Intel Server Board S5000PAL / S5000XAL TPS List of TablesList of Tables Intel Server Board S5000PAL / S5000XAL TPS Page Chapter Outline Server Board Use DisclaimerIntroduction Intel Server Board S5000PAL / S5000XAL TPS 12Revision Intel order number D31979-007Intel Server Board S5000PAL / S5000XAL TPS Product Overview Intel Server Board S5000PAL / S5000XAL Feature SetFeature Description 14Revision Intel order number D31979-007 Server Board LayoutProduct Overview Intel Server Board S5000PAL / S5000XAL TPS Connector and Component Locations Sata Light Guided Diagnostic LED Locations LDMExternal I/O Connector Locations Server Board Mechanical Drawings 40.39 PCI BKT Drop Down TP02294 10.16 16.51 113.13 199.21 285.75 182.83 274.32 298.51 Functional Architecture Processor Support Intel 5000P and 5000X Memory Controller Hubs MCHSystem Bus Interface Processor Population Rules Common Enabling Kit CEK Design SupportProcessor Support Matrix 26Revision Intel order number D31979-007Memory Sub-system CEK Processor MountingMemory Rasum Featuresi Supported MemoryDimm Population Rules and Supported Dimm Configurations Minimum Non-Mirrored Mode ConfigurationBranch Channel B Channel a Non-mirrored mode memory upgrades Recommended Four Dimm ConfigurationSingle Branch Mode Sparing Dimm Configuration 32Revision Intel order number D31979-007ESB-2 IO Controller Snoop Filter 5000X MCH onlyPCI Sub-system 1.1 PCI32 32-bit, 33-MHz PCI Bus SegmentPXA 64-bit, 133MHz PCI-X* Bus Segment 1.3 PE1 One x4 PCI Express* Bus SegmentPCI Riser Slots 1.5 PE4, PE5 Two x4 PCI Express* Bus Segments1.6 PE6, PE7 Two x4 PCI Express* Bus Segments 36Revision Intel order number D31979-007 Serial ATA SupportIntel Embedded Server RAID Technology II Support Video Support Parallel ATA Pata SupportUSB 2.0 Support Intel Embedded Server RAID Technology Option ROMVideo Modes Video Memory InterfaceDual Video Video ModesNetwork Interface Controller NIC Intel I/O Acceleration TechnologyMAC Address Definition NIC2 Status LEDPin Signal Name Serial Port a Header Pin-out Super I/OSerial Ports Serial a Header Pin-outPins What happens at system reset… RJ45 Signal AbbreviationFloppy Disk Controller Keyboard and Mouse Support42Revision Intel order number D31979-007 Wake-up ControlSystem Health Support Platform Management 44Revision Intel order number D31979-007 Board Connector InformationBoard Connector Matrix Power Connectors Power Connector Pin-out J3K3Power Connector Pin-out J3K4 Power Supply Signal Connector Pin-out J1K1Intel Remote Management Module RMM Connector Intel RMM Connector Pin-out J1C5Pin Signal Name System Management HeadersIntel RMM NIC Connector Pin Intel RMM NIC Module Connector Pin-out J1B2Ipmb Header Riser Card Slots3 LCP/AUX Ipmb Header Pin Side B PCI Spec Signal Pin Side a PCI Spec SignalPin-Side B PCI Spec Signal Pin-Side a PCI Spec Signal Full-height Riser Slot Pin-out J4F150Revision Intel order number D31979-007 Pin-Side B PCI Spec Signal Pin-Side a 52Revision Intel order number D31979-007 PAR64SSI Control Panel Connector Bridge Board ConnectorFront Panel SSI Standard 24-pin Connector Pin-out J3H2 Pin Bridgeboard Connector Pin-out J4G154Revision Intel order number D31979-007 I/O Connector Pin-out Definition VGA ConnectorNIC Connectors VGA Connector Pin-out J6A1IDE Connector Intel I/O Expansion Module ConnectorPin IDE Connector Pin-out J3G1 56Revision Intel order number D31979-007Sata Connectors Sata Connector Pin-out J1H1, J1G2, J1G1, J1F2, J1E3Serial Port Connectors Keyboard and Mouse ConnectorInternal USB Connector Pin-out J1J1 USB 2.0 ConnectorsExternal USB Connector Pin-out J5A1, J6A2 SSI Fan Connector Pin-out J9K1,J5K1,J3K1,J3K2,J7A2,J7A1 Pin Signal Name Type DescriptionFan Headers 60Revision Intel order number D31979-007Jumper Name Pins What happens at system reset… Recovery Jumper BlocksRecovery Jumpers J1D1, J1D2, J1D3 62Revision Intel order number D31979-007 Cmos Clear and Password Reset Usage ProcedureBMC Force Update Procedure Bios Select Jumper Bios Select Jumper J3H1External RJ45 Serial Port Jumper Block Light Guided Diagnostics 5-Volt Standby LEDSystem ID LED and System Status LED 66Revision Intel order number D31979-007System Status LED BMC Initialization Color State Criticality DescriptionDimm Fault LEDs Processor Fault LEDPost Code Diagnostic LEDs Server Board Design Specifications 70Revision Intel order number D31979-007TDP Power Max Tcase Icc MAX 130 W 70º C 150 a Server Board Power RequirementsProcessor Power Support Turn On No Load Operation Load RatingsNo load operating range 72Revision Intel order number D31979-007Grounding Standby OutputsRemote Sense Voltage RegulationCommon Mode Noise Dynamic LoadingCapacitive Loading Closed-Loop StabilityRipple / Noise Soft StartingTiming Requirements Ripple and NoiseOut 10% V out MIN MAX Units Residual Voltage Immunity in Standby Mode 78Revision Intel order number D31979-007Reference Example Product Safety & Electromagnetic EMC ComplianceAustralia / New Zealand AS/NZS 3548 Emissions Electromagnetic Compatibility Notices FCC Verification Statement USAICES-003 Canada Europe CE Declaration of ConformityEnglish translation of the notice above Bsmi TaiwanRRL Korea Product Ecology Compliance Compliance Compliance Reference Description Marking Example Other MarkingsJapan Recycling Appendix a Integration and Usage Tips 84Revision Intel order number D31979-007ƒ Assertion / De-assertion Enables ƒ Sensor Typeƒ Event / Reading Type ƒ Event Offset/Triggersƒ Default Hysteresis ƒ Criticalityƒ Standby 86Revision Intel order number D31979-007Value Bility Type NMI STB Revision Revision Intel order number D31979-007 Revision Acpi Bios EPS PCIe Link1 Revision Dimm A2 Dimm D2 ECC 100 Revision Intel order number D31979-007 B01 DimmPost Progress Code LED Example LEDs Red Green102Revision Intel order number D31979-007 Revision 103 Intel order number D31979-007 104Revision Intel order number D31979-007 Runtime Phase / EFI Operating System BootPre-EFI Initialization Module Peim / Recovery Revision Intel order number D31979-007 105 Post Error Messages and HandlingError Code Error Message Response 106Revision Intel order number D31979-007 ROMPost Error Beep Codes Post Error Beep CodesBMC Beep Codes Revision 107 Intel order number D31979-007Appendix E Supported Intel Server Chassis Page Slim-Line Optical Drive Bay Term Definition Intel Server Board S5000PAL / S5000XAL TPS GlossaryRevision 111 Intel order number D31979-007 Glossary Intel Server Board S5000PAL / S5000XAL TPS 112Revision Intel order number D31979-007Revision 113 Intel order number D31979-007 Reference Documents 114Revision Intel order number D31979-007