Intel S5000XAL manual System Status LED BMC Initialization, Color State Criticality Description

Page 66

Intel® Server Board S5000PAL / S5000XAL TPS

Light Guided Diagnostics

The bi-color System Status LED will operate as follows:

Color

State

Criticality

 

Description

Off

N/A

Not ready

AC power off

Green /

Alternating

Not ready

Pre DC Power On – 15-20 second BMC Initialization when AC is

Amber

Blink

 

applied to the server. Control Panel buttons are disabled until BMC

 

 

 

initialization is complete.

Green

Solid on

System OK

System booted and ready.

Green

Blink

Degraded

System degraded

 

 

 

Unable to use all of the installed memory (more than one

 

 

 

 

DIMM installed).

 

 

 

Correctable errors over a threshold of 10 and migrating to a

 

 

 

 

spare DIMM (memory sparing). This indicates that the user

 

 

 

 

no longer has spared DIMMs indicating a redundancy lost

 

 

 

 

condition. Corresponding DIMM LED should light up.

 

 

 

In mirrored configuration, when memory mirroring takes

 

 

 

 

place and system loses memory redundancy. This is not

 

 

 

 

covered by (2).

 

 

 

Redundancy loss such as power-supply or fan. This does

 

 

 

 

not apply to non-redundant sub-systems.

 

 

 

PCI-e link errors

 

 

 

CPU failure / disabled – if there are two processors and one

 

 

 

 

of them fails

 

 

 

Fan alarm – Fan failure. Number of operational fans should

 

 

 

 

be more than minimum number needed to cool the system

 

 

 

Non-critical threshold crossed – Temperature and voltage

Amber

Blink

Non-critical

Non-fatal alarm – system is likely to fail

 

 

 

Critical voltage threshold crossed

 

 

 

VRD hot asserted

 

 

 

Minimum number of fans to cool the system not present or

 

 

 

 

failed

 

 

 

In non-sparing and non-mirroring mode if the threshold of

 

 

 

 

ten correctable errors is crossed within the window

 

 

 

 

Amber

Solid on

Critical, non-

Fatal alarm – system has failed or shutdown

 

 

recoverable

DIMM failure when there is one DIMM present, no good

 

 

 

 

memory present

 

 

 

Run-time memory uncorrectable error in non-redundant

 

 

 

 

mode

 

 

 

IERR signal asserted

 

 

 

Processor 1 missing

 

 

 

Temperature (CPU ThermTrip, memory TempHi, critical

 

 

 

 

threshold crossed)

 

 

 

No power good – power fault

 

 

 

Processor configuration error (for instance, processor

 

 

 

 

stepping mismatch)

7.2.1System Status LED – BMC Initialization

When the AC power is first applied to the system and 5V-STBY is present, the BMC controller on the server board requires 15-20 seconds to initialize. During this time, the system status LED will blink, alternating between amber and green, and the power button functionality of the control panel is disabled preventing the server from powering up. Once BMC initialization has completed, the status LED will stop blinking and the power button functionality is restored and can be used to turn on the server.

Revision 1.4

67

 

Intel order number: D31979-007

Image 66
Contents Revision Intel order number D31979-007Iii Intel Server Board S5000PAL / S5000XAL TPSRevision HistoryDate Revision Modifications Number Disclaimers Disclaimers Intel Server Board S5000PAL / S5000XAL TPSTable of Contents Jumper Block Settings Light Guided DiagnosticsPower and Environmental Specifications 108 101105 111List of Figures Intel Server Board S5000PAL / S5000XAL TPS Viii Revision Intel order number D31979-007List of Tables Intel Server Board S5000PAL / S5000XAL TPS List of TablesList of Tables Intel Server Board S5000PAL / S5000XAL TPS Page Introduction Intel Server Board S5000PAL / S5000XAL TPS Chapter OutlineServer Board Use Disclaimer 12Revision Intel order number D31979-007Intel Server Board S5000PAL / S5000XAL Feature Set Feature DescriptionIntel Server Board S5000PAL / S5000XAL TPS Product Overview Server Board Layout Product Overview Intel Server Board S5000PAL / S5000XAL TPS14Revision Intel order number D31979-007 Connector and Component Locations Sata Light Guided Diagnostic LED Locations LDMExternal I/O Connector Locations Server Board Mechanical Drawings 40.39 PCI BKT Drop Down TP02294 10.16 16.51 113.13 199.21 285.75 182.83 274.32 298.51 Functional Architecture Intel 5000P and 5000X Memory Controller Hubs MCH System Bus InterfaceProcessor Support Processor Support Matrix Processor Population RulesCommon Enabling Kit CEK Design Support 26Revision Intel order number D31979-007Memory Sub-system CEK Processor MountingMemory Rasum Featuresi Supported MemoryDimm Population Rules and Supported Dimm Configurations Minimum Non-Mirrored Mode ConfigurationBranch Channel B Channel a Non-mirrored mode memory upgrades Recommended Four Dimm ConfigurationSingle Branch Mode Sparing Dimm Configuration 32Revision Intel order number D31979-007ESB-2 IO Controller Snoop Filter 5000X MCH onlyPXA 64-bit, 133MHz PCI-X* Bus Segment PCI Sub-system1.1 PCI32 32-bit, 33-MHz PCI Bus Segment 1.3 PE1 One x4 PCI Express* Bus Segment1.5 PE4, PE5 Two x4 PCI Express* Bus Segments 1.6 PE6, PE7 Two x4 PCI Express* Bus SegmentsPCI Riser Slots Serial ATA Support Intel Embedded Server RAID Technology II Support36Revision Intel order number D31979-007 USB 2.0 Support Video SupportParallel ATA Pata Support Intel Embedded Server RAID Technology Option ROMDual Video Video ModesVideo Memory Interface Video ModesMAC Address Definition Network Interface Controller NICIntel I/O Acceleration Technology NIC2 Status LEDSerial Ports Pin Signal Name Serial Port a Header Pin-outSuper I/O Serial a Header Pin-outFloppy Disk Controller Pins What happens at system reset…RJ45 Signal Abbreviation Keyboard and Mouse SupportWake-up Control System Health Support42Revision Intel order number D31979-007 Platform Management Board Connector Information Board Connector Matrix44Revision Intel order number D31979-007 Power Connector Pin-out J3K4 Power ConnectorsPower Connector Pin-out J3K3 Power Supply Signal Connector Pin-out J1K1Pin Signal Name Intel Remote Management Module RMM ConnectorIntel RMM Connector Pin-out J1C5 System Management HeadersIntel RMM NIC Connector Pin Intel RMM NIC Module Connector Pin-out J1B2Riser Card Slots 3 LCP/AUX Ipmb HeaderIpmb Header Pin-Side B PCI Spec Signal Pin-Side a PCI Spec Signal Pin Side B PCI Spec SignalPin Side a PCI Spec Signal Full-height Riser Slot Pin-out J4F150Revision Intel order number D31979-007 Pin-Side B PCI Spec Signal Pin-Side a 52Revision Intel order number D31979-007 PAR64Front Panel SSI Standard 24-pin Connector Pin-out J3H2 SSI Control Panel ConnectorBridge Board Connector Pin Bridgeboard Connector Pin-out J4G154Revision Intel order number D31979-007 NIC Connectors I/O Connector Pin-out DefinitionVGA Connector VGA Connector Pin-out J6A1Pin IDE Connector Pin-out J3G1 IDE ConnectorIntel I/O Expansion Module Connector 56Revision Intel order number D31979-007Sata Connectors Sata Connector Pin-out J1H1, J1G2, J1G1, J1F2, J1E3Serial Port Connectors Keyboard and Mouse ConnectorUSB 2.0 Connectors External USB Connector Pin-out J5A1, J6A2Internal USB Connector Pin-out J1J1 Fan Headers SSI Fan Connector Pin-out J9K1,J5K1,J3K1,J3K2,J7A2,J7A1Pin Signal Name Type Description 60Revision Intel order number D31979-007Recovery Jumper Blocks Recovery Jumpers J1D1, J1D2, J1D3Jumper Name Pins What happens at system reset… Cmos Clear and Password Reset Usage Procedure BMC Force Update Procedure62Revision Intel order number D31979-007 Bios Select Jumper Bios Select Jumper J3H1 External RJ45 Serial Port Jumper Block Light Guided Diagnostics 5-Volt Standby LEDSystem ID LED and System Status LED 66Revision Intel order number D31979-007System Status LED BMC Initialization Color State Criticality DescriptionDimm Fault LEDs Processor Fault LEDPost Code Diagnostic LEDs Server Board Design Specifications 70Revision Intel order number D31979-007Server Board Power Requirements Processor Power SupportTDP Power Max Tcase Icc MAX 130 W 70º C 150 a No load operating range Turn On No Load OperationLoad Ratings 72Revision Intel order number D31979-007Remote Sense GroundingStandby Outputs Voltage RegulationCapacitive Loading Common Mode NoiseDynamic Loading Closed-Loop StabilityTiming Requirements Ripple / NoiseSoft Starting Ripple and NoiseOut 10% V out MIN MAX Units Residual Voltage Immunity in Standby Mode 78Revision Intel order number D31979-007Product Safety & Electromagnetic EMC Compliance Australia / New Zealand AS/NZS 3548 EmissionsReference Example ICES-003 Canada Electromagnetic Compatibility NoticesFCC Verification Statement USA Europe CE Declaration of ConformityBsmi Taiwan RRL KoreaEnglish translation of the notice above Product Ecology Compliance Other Markings Japan RecyclingCompliance Compliance Reference Description Marking Example Appendix a Integration and Usage Tips 84Revision Intel order number D31979-007ƒ Event / Reading Type ƒ Assertion / De-assertion Enablesƒ Sensor Type ƒ Event Offset/Triggersƒ Standby ƒ Default Hysteresisƒ Criticality 86Revision Intel order number D31979-007Value Bility Type NMI STB Revision Revision Intel order number D31979-007 Revision Acpi Bios EPS PCIe Link1 Revision Dimm A2 Dimm D2 ECC 100 Revision Intel order number D31979-007 B01 DimmPost Progress Code LED Example LEDs Red Green102Revision Intel order number D31979-007 Revision 103 Intel order number D31979-007 Runtime Phase / EFI Operating System Boot Pre-EFI Initialization Module Peim / Recovery104Revision Intel order number D31979-007 Post Error Messages and Handling Error Code Error Message ResponseRevision Intel order number D31979-007 105 106Revision Intel order number D31979-007 ROMBMC Beep Codes Post Error Beep CodesPost Error Beep Codes Revision 107 Intel order number D31979-007Appendix E Supported Intel Server Chassis Page Slim-Line Optical Drive Bay Intel Server Board S5000PAL / S5000XAL TPS Glossary Revision 111 Intel order number D31979-007Term Definition Glossary Intel Server Board S5000PAL / S5000XAL TPS 112Revision Intel order number D31979-007Revision 113 Intel order number D31979-007 Reference Documents 114Revision Intel order number D31979-007