Intel 537EX manual Decimal value and the format is as follows, +ER=m, Display messages when +ER =

Page 62

Error Correction and Data Compression

Table 21. V.44/V.42/V.42 bis and MNP Data Modem Command Descriptions (Continued)

Command

Default

 

 

Description

 

 

 

 

 

Error Control Reporting: Controls whether the “+ER:” result code is transmitted from the DCE to the

 

 

DTE once a connection has been made. If enabled the result code displayed shall represent the current

 

 

negotiated DCE-DCE error control type and is issued after the Modulation Report (+MCR and +MRR) and

 

 

before the final result code Data Compression Report (+DR:). +ER accepts one numeric parameter

 

 

decimal value and the format is as follows:

 

 

0

Disables error control reporting (no +ER intermediate result code transmitted)

 

 

1

Enables error control reporting (+ER intermediate result code transmitted)

+ER=m

0

Display messages when +ER = 1,

+ER: LAPM

 

V42 LAPM protocol in use

 

 

 

 

 

+ER: MNP 2

 

MNP 2 protocol in use

 

 

+ER: MNP 2 4

MNP 2 and 4 protocol in use

 

 

+ER: MNP 3

 

MNP 3 protocol in use

 

 

+ER: MNP 3 4

MNP 3 and 4 protocol in use

 

 

Example if +ER = 1

 

 

 

+ER: LAPM

 

 

 

 

 

 

 

NOTE: An asterisk (*) denotes the factory-default setting.

62

536EX Chipset Developer’s Manual

Intel Confidential

Image 62
Contents 537EX Chipset Developer’s ManualIntel Confidential Contents Figures Tables 001 Initial release Revision HistoryDate Revision Description Introduction Controllerless Modem Driver OverviewWindows 95 and Windows Unimodem V.90/V.92 and V.34 Data ModesTapi Intelsdb.VXDModem Connection Overview DCE-to-DCE Data Rates for Each Mode AT Commands OverviewDTE-to-DCE Data Rates for Each Mode DCE-to-ISP Data Rates for V.90 ModeDTE-Modem Data Rate Response Codes Sending CommandsDelayed Call Numeric TextDial Modifier Command FunctionAT Escape Sequences Dialing digitsData Mode Command Summary Command Function Default Range Reported By &VnIntel Confidential Intel Confidential Intel Confidential +ESR +EB+ESA +ETBM44/V.42/V.42 bis MNP Command Summary Processes flow control characters and passes to local Fax Identity Command Summary Fax Class 1 Command SummaryResponse Hex Code Function IS-101 Voice Command SummaryVoice DTE→DCE Character Pairs DEL Voice DTE →DCE Character PairsVoice DTE←DCE Character Pairs ESCRegister Summary Register Function Default Range Units Reported by &VnDial Modifiers AsciiRegister Function Default Range Units Modem Setup Host Modem Response Command Using AT Commands to Access the S-Registers Sn?, Sn=x, ?Modem Responses and Command Echo En, Vn, Xn, Wn, Qn DTE Disable EnableData Reporting Wn Mapping Resets and then configures the modem to Nvram user profile Product Identification Information AT Commands Product InformationEstablishing a Modem Connection A, D, DS = n, S0 Modem-to-Modem Connection Data Rates Online Command Mode Escape Codes, OnHanging Up Hn, S10, Zn, &D2 Intel Confidential Modem-on-Hold Incoming Voice Call in Data Mode Modem-on-Hold Initiating a Voice Call in Data Mode Intel Confidential Supported Modulation Types Carrier DescriptionDiagnostic Testing S18, &Tn Local Analog Loopback AT&T1Local Analog Loopback With Self-Test AT&T8 Local Modem or Test ModemLicensing Requirements for Hayes Escape Sequence AT Escape SequencesTime-Independent Escape Sequence Example Hayes* Escape Sequence Data Mode Command DescriptionsCommand Default Description Echo disabled Previously stored in the Nvram with the AT&Zn=x commandHost in either online or off-line command mode Echo enabledSn=x ATI2DTE Numeric or verbose form CommandModem dials a telephone number touch tone dialing Numeric formResets the modem and recalls user profile DisconnectingSubsequent commands to be ignored DCD or Rlsd signalStored Profile AT&V0Active Profile Telephone NumbersSelect profile S-register configurations into the Nvram user profile ‘n’Command to see the stored telephone number = 0-9 a B C D # * T P R W @Command Default Indication Definition+EB Secondary channel operation, and vice versa CRC generation and checking disabledNrzi encoding and decoding disabled 12/V.34+ESR +ETBM+IFC +GMR+GSN +ILRR=m= carrier,carrier,…carrier +MS command description+MA? will display a list of enabled alternative modulations If +MS = ,0,, no alternative modulations will be availableBELL212 Carrier DescriptionBELL103 +MS=m See ‘m’Value Description +PHSW=+PMHF +PMHREnable Short Phase Conjunction with the +PSS commandEnable Short Phase 1 and Short Phase Disable short Phase 1 and Short PhaseMode Features Operating ModesResulting +ES Connection Types 44/V.42/V.42 bis and MNP Data Modem Command Descriptions+ES Settings Answer Modem +ES=1, 0 +ES=4, 4 +ES=3, 0 +ES=3, 2\Bn \Kn +DS=m +DR=mDirection Max string3768 +EFCS=m+ER=m Display messages when +ER =Decimal value and the format is as follows +ER LapmNon-error control operation Setting is ignored if origrqst=6Control during non-error control operation +ES=mFax Identity Command Descriptions Fax Identity CommandsFax Class 1 Commands +FMFR?/+FMIMod Selection Table Value Modulation Speed bps30 Hdlc Frame Format Class 1 DTE-Generated Hdlc Frame Information AT+FTH=mod+FCLASS Fax Mode Command Descriptions+FCLASS? +FRH=m +FRS=m+FTH=m IS-101 Voice Mode AT Commands Relay Control Voice Mode Command DescriptionsDtmf Detection Reporting +FLO=m Enable report Function +VDR=m See ‘m’Event Description Defaults = ‘C’, BB860980, BFE63883, BB863EE0Caller ID report Command Reserved Distinctive ringing All +VEM=m See ‘m’HEX Digit Location EIGHT-DIGIT HEX Code B B 8 6 3 E EEX Value BIT Value Event +VIP Local telephone, or speaker128 Nominal transmit level +VLS=m Preassigned Voice I/O LabelsLabel Primitive Code Description Voice I/O Primitive CodesRelay/Playback Control +VRX +VSD=m See ‘m’+VSM=m +VSM=? command to obtain supported sampling rates141 AD3 3-bit Adaptive differential pulse code modulation Range 4800, 7200, 8000, and 11025 samples/secondHard Disk CmlSerial Compression100 Factory default is ‘0’100 Default value 1 second Range 5-255 units of 0.01 secondsSpecified by +VTD=m Dual tones may be sent using the following format+VTS=m None This sends a 500 ms period of silenceCommand Default Description Register Command Descriptions S10 S16 Range Seconds Default 0 secondsEscape sequences S25 S21S22 118 S30Sleep mode is disabled by setting S33 to ‘0’ Modem exits sleep mode whenever the host reads or writes toModem or when a ring signal is detected Inactive state whenCaller ID Tags for Formatted Reporting Tag DescriptionRing Uart Emulation in the Controllerless Modem Uart Emulation in Intelsdb.VxDRBR UartTHR Parallel Host Interface Uart Register Bit Assignments Modem Status Register MSR Uart Register DefinitionsScratch Register SCR Line Status Register LSR Bit Framing errorOE Overrun Error-Not supported StackModem Control Register MCR IER Interrupt Enable registerProcedure is as follows Line Control Register LCRFifo Control Register FCR BitID1 ID0 Interrupt Identity Register IIRInterrupt Control Functions Transmitter Holding Register THR Interrupt Enable Register IERID bit 2 for Fifo mode Dlab =Programmable Data Rates Receiver Buffer Register RBRDivisor Latch Registers DLM and DLL Data Rate Divisor Number Divisor Latch Hex16C550A Uart Fifo Operation Fifo Interrupt Mode OperationFifo Polled Mode Operation 102536EX Chipset Developer’s Manual 103