AT Command Summary Tables

Table 6. V.44/V.42/V.42 bis MNP Command Summary (Continued)

Note

Command

Function

 

Default

Range

Reported

 

by &Vn

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3, 0, 0,

 

 

 

 

 

 

471,

 

 

 

 

 

 

942,

 

no

 

+DS44=m

V.44 Data Compression

140,

 

 

 

 

 

140,

 

 

 

 

 

 

1884,

 

 

 

 

 

 

3768

 

 

 

 

 

 

 

 

 

+EFCS

Controls the 32-bit frame check sequence option in

0

0–2

no

 

V.42

 

 

 

 

 

 

 

 

 

 

 

 

+ER=m

Controls error control reporting

0

0, 1

no

 

 

 

 

 

 

 

m=0

Disabled

 

 

 

 

 

 

 

 

 

 

m=1

Enabled

 

 

 

 

 

 

 

 

 

*

+ES=m

Error control selection

3, 0, 2

See note

yes

 

 

 

 

 

 

 

* Value saved in NVRAM.

Table 7. Fax Identity Command Summary

Command

Function

Default

Range

Reported by &Vn

 

 

 

 

 

+FMDL?

Identifies product model

none

no

 

 

 

 

 

+FMFR?

Identifies modem manufacturer

none

no

 

 

 

 

 

+FMI

Identifies modem manufacturer

none

no

 

 

 

 

 

+FMM

Identifies product model

none

no

 

 

 

 

 

+FMR

Identifies product version number

none

no

 

 

 

 

 

+FREV?

Identifies product version number

none

no

 

 

 

 

 

Table 8. Fax Class 1 Command Summary

Command

Function

Default

Range

Reported

by &Vn

 

 

 

 

 

 

 

 

 

+FCLASS=1

Mode selection

0

0, 1, 8

no

 

 

 

 

 

+FRH=m

Receive HDLC data

none

3

no

 

 

 

 

 

+FRM=m

Receive data

none

24, 48, 72, 73, 74, 96, 97, 98, 121, 122,

no

145, 146

 

 

 

 

 

 

 

 

 

+FRS=m

Wait for silence

none

1–255

no

 

 

 

 

 

+FTH=m

Transmit HDLC data

none

3

no

 

 

 

 

 

+FTM=m

Transmit data

none

24, 48, 72, 73, 74, 96, 97, 98, 121, 122,

no

145, 146

 

 

 

 

 

 

 

 

 

+FTS=m

Stop transmission and pause

none

0–255

no

 

 

 

 

 

536EX Chipset Developer’s Manual

21

Intel Confidential

Image 21
Contents Developer’s Manual 537EX ChipsetIntel Confidential Contents Figures Tables Revision History Date Revision Description001 Initial release Controllerless Modem Driver Overview IntroductionWindows 95 and Windows Tapi V.90/V.92 and V.34 Data ModesUnimodem Intelsdb.VXDModem Connection Overview DTE-to-DCE Data Rates for Each Mode AT Commands OverviewDCE-to-DCE Data Rates for Each Mode DCE-to-ISP Data Rates for V.90 ModeDelayed Call Sending CommandsDTE-Modem Data Rate Response Codes Numeric TextAT Escape Sequences Command FunctionDial Modifier Dialing digitsCommand Function Default Range Reported By &Vn Data Mode Command SummaryIntel Confidential Intel Confidential Intel Confidential +ESA +EB +ESR +ETBM44/V.42/V.42 bis MNP Command Summary Processes flow control characters and passes to local Fax Class 1 Command Summary Fax Identity Command SummaryIS-101 Voice Command Summary Voice DTE→DCE Character PairsResponse Hex Code Function Voice DTE←DCE Character Pairs Voice DTE →DCE Character PairsDEL ESCDial Modifiers Register Function Default Range Units Reported by &VnRegister Summary AsciiRegister Function Default Range Units Using AT Commands to Access the S-Registers Sn?, Sn=x, ? Modem Responses and Command Echo En, Vn, Xn, Wn, QnModem Setup Host Modem Response Command Disable Enable Data Reporting Wn MappingDTE Resets and then configures the modem to Nvram user profile AT Commands Product Information Establishing a Modem Connection A, D, DS = n, S0Product Identification Information Online Command Mode Escape Codes, On Hanging Up Hn, S10, Zn, &D2Modem-to-Modem Connection Data Rates Intel Confidential Modem-on-Hold Incoming Voice Call in Data Mode Modem-on-Hold Initiating a Voice Call in Data Mode Intel Confidential Carrier Description Supported Modulation TypesLocal Analog Loopback AT&T1 Diagnostic Testing S18, &TnLocal Modem or Test Modem Local Analog Loopback With Self-Test AT&T8AT Escape Sequences Time-Independent Escape SequenceLicensing Requirements for Hayes Escape Sequence Example Data Mode Command Descriptions Command Default DescriptionHayes* Escape Sequence Host in either online or off-line command mode Previously stored in the Nvram with the AT&Zn=x commandEcho disabled Echo enabledATI2 DTESn=x Modem dials a telephone number touch tone dialing CommandNumeric or verbose form Numeric formSubsequent commands to be ignored DisconnectingResets the modem and recalls user profile DCD or Rlsd signalActive Profile AT&V0Stored Profile Telephone NumbersCommand to see the stored telephone number S-register configurations into the Nvram user profile ‘n’Select profile = 0-9 a B C D # * T P R W @Indication Definition Command Default+EB Nrzi encoding and decoding disabled CRC generation and checking disabledSecondary channel operation, and vice versa 12/V.34+ETBM +ESR+GSN +GMR+IFC +ILRR=m+MA? will display a list of enabled alternative modulations +MS command description= carrier,carrier,…carrier If +MS = ,0,, no alternative modulations will be availableBELL103 Carrier DescriptionBELL212 +MS=m See ‘m’+PMHF +PHSW=Value Description +PMHREnable Short Phase 1 and Short Phase Conjunction with the +PSS commandEnable Short Phase Disable short Phase 1 and Short PhaseOperating Modes Mode Features+ES Settings Answer Modem 44/V.42/V.42 bis and MNP Data Modem Command DescriptionsResulting +ES Connection Types +ES=1, 0 +ES=4, 4 +ES=3, 0 +ES=3, 2\Bn \Kn Direction +DR=m+DS=m Max string+EFCS=m 3768Decimal value and the format is as follows Display messages when +ER =+ER=m +ER LapmControl during non-error control operation Setting is ignored if origrqst=6Non-error control operation +ES=mFax Class 1 Commands Fax Identity CommandsFax Identity Command Descriptions +FMFR?/+FMIValue Modulation Speed bps Mod Selection TableClass 1 DTE-Generated Hdlc Frame Information AT+FTH=mod 30 Hdlc Frame FormatFax Mode Command Descriptions +FCLASS?+FCLASS +FRS=m +FRH=m+FTH=m IS-101 Voice Mode AT Commands Voice Mode Command Descriptions Dtmf Detection ReportingRelay Control +FLO=m +VDR=m See ‘m’ Enable report FunctionCaller ID report Command Reserved Distinctive ringing All Defaults = ‘C’, BB860980, BFE63883, BB863EE0Event Description +VEM=m See ‘m’EIGHT-DIGIT HEX Code B B 8 6 3 E E EX Value BIT Value EventHEX Digit Location Local telephone, or speaker 128 Nominal transmit level+VIP Preassigned Voice I/O Labels Label+VLS=m Voice I/O Primitive Codes Relay/Playback ControlPrimitive Code Description +VSD=m See ‘m’ +VRX141 AD3 3-bit Adaptive differential pulse code modulation +VSM=? command to obtain supported sampling rates+VSM=m Range 4800, 7200, 8000, and 11025 samples/secondSerial CmlHard Disk Compression100 Default value 1 second Factory default is ‘0’100 Range 5-255 units of 0.01 seconds+VTS=m None Dual tones may be sent using the following formatSpecified by +VTD=m This sends a 500 ms period of silenceCommand Default Description Register Command Descriptions S10 Range Seconds Default 0 seconds Escape sequencesS16 S22 118 S21S25 S30Modem or when a ring signal is detected Modem exits sleep mode whenever the host reads or writes toSleep mode is disabled by setting S33 to ‘0’ Inactive state whenTag Description Caller ID Tags for Formatted ReportingRing Uart Emulation in Intelsdb.VxD Uart Emulation in the Controllerless ModemUart THRRBR Parallel Host Interface Uart Register Bit Assignments Uart Register Definitions Scratch Register SCRModem Status Register MSR OE Overrun Error-Not supported Bit Framing errorLine Status Register LSR StackProcedure is as follows IER Interrupt Enable registerModem Control Register MCR Line Control Register LCRBit Fifo Control Register FCRInterrupt Identity Register IIR Interrupt Control FunctionsID1 ID0 ID bit 2 for Fifo mode Interrupt Enable Register IERTransmitter Holding Register THR Dlab =Divisor Latch Registers DLM and DLL Receiver Buffer Register RBRProgrammable Data Rates Data Rate Divisor Number Divisor Latch HexFifo Polled Mode Operation Fifo Interrupt Mode Operation16C550A Uart Fifo Operation 102536EX Chipset Developer’s Manual 103