Intel Raptor AT manual On-board Devices, PCI Configuration Space Map

Page 55

 

Appendix A: Technical Specifications

 

 

Address (hex)

Description

03D4-03D5

Video (VGA)

03DA

Video (VGA)

03E8-03EF

COM3 (if selected)

03F0-03F5

Floppy Channel 1

03F6

Primary IDE channel command port

03F7

Floppy Channel 1 command

03F7, bit 7

Floppy disk change channel 1

03F7, bits 6:0

Primary IDE channel status report

03F8-03FF

COM1 (default)

04D0-04D1

INTC-1 Edge/Level Control

0CF8-0CFB - 4

PCI configuration address register

bytes

 

0CF9

Reset control register

0CFC-0CFF - 4

PCI configuration data register

bytes

 

On-board Devices

DISK ON CHIP 1

Memory address selectable between:

D000(default), D400, D800, DC00.

DISK ON CHIP 2

Memory address selectable between:

D000, D400(default), D800, DC00.

PCI Configuration Space Map

Bus #

Device #

Function #

Description

00

00

00

440BX (Host Bridge)

00

07

00

PIIX4 PCI/ISA bridge

00

07

01

PIIX4 IDE bus master

00

07

02

PIIX4 USB

00

07

03

PIIX4 Power Management

00

0F

00

PCI expansion slot 1

00

10

00

PCI expansion slot 2

00

12

00

PCI expansion slot 3

45

Image 55
Contents Raptor AT Page Chapter Pre-ConfigurationAppendix B Flash Bios Programming Appendix C Disk-On-Chip Appendix a Technical SpecificationsAppendix E On-Board Appendix D On-Board IndustrialRaptor AT Installation Guide Introduction System Board Pre-ConfigurationStatic Electricity Warning On-Board I/O CPU SupportSupported Bus Clocks MemoryOn-Board Ethernet Conventions Used in this ManualStatic Warning Pre-ConfigurationRaptor AT Installation Guide Jumper Types Jumper Locations Jumper LocationsFlash Write-protect Enabled Disabled Cmos ResetReset Cmos Normal Clear Cmos Flash Bios Write ProtectClock JP11 Watchdog Timer SelectionTimeout Clock Speed SelectionATX Power Supply Enhancements Ethernet Selection Enabled DisabledAddress 110h Closed Open 310h CPU Installation Raptor AT Memory ConfigurationFan Heatsink Designing for thermal performanceAirflow management Disk-on-Chip installationInstalling Cables Power and Control Panel Cables Installing Peripheral CablesPre-Configuration Location of Components and Connectors Connector Description Index of ConnectorsUsers Notes Bios Setup Main Menu SetupStarting Bios Setup Using the Keyboard with Bios SetupDate/Time Standard SetupFloppy Drive A, B Pri Master Pri Slave Sec Master Sec Slave Advanced Cmos SetupBoot Sector Virus Protection Quick BootHard Disk Access Control Try Other Boot DevicesInitial Display Mode Floppy Access ControlFloppy Drive Seek Boot Up Num LockA.R.T. for Hard Disks Floppy Drive SwapPrimary Display Password CheckBoot to OS/2 Wait for F1 If ErrorC000,16K Shadow C400,16K Shadow Advanced Chipset SetupSystem Bios Cacheable Internal CacheUSB KB/Mouse Legacy Support BX/GX Master Latency Timer ClksMulti-Trans Timer Clks PCI 1 to PCI 0 AccessSdram RAS# to CAS# Delay Aperture Access Global EnablePCI 0 Agent to Aperture Access Memory Autosizing Support Dram Integrity ModeSdram Precharge Control Power Down SdramSearch for MDA Resources Bit I/O Recovery Time 16bit I/O Recovery TimePower Management Setup Video Power Down Mode Power Management/APMPower button Function Green PC Monitor Power StateSuspend Timeout Power Saving TypeStandby / Suspend Timer Unit Standby TimeoutPlug and Play Aware OS PCI/Plug and Play SetupPCI Latency Timer PCI Clocks LAN Wake-UpOff-board PCI IDE Card PCI VGA Palette SnoopAllocate IRQ to PCI VGA PCI IDE Bus MasterDMA Channel Off-board PCI IDE Secondary IRQPCI Device Search Order Peripheral SetupReserved Memory Size Reserved Memory AddressOnboard Serial Port1 Serial Port2 ModeInfra-Red Transmission Mode Parallel Port ModeParallel Port IRQ CPU Current TemperatureCPU Overheat Warning Temperature EPP VersionOnboard IDE Change User PasswordAuto Detect Hard Disk CPU Fan Secondary FanChange Supervisor Password Save Settings and Exit Auto Configuration with Fail-Safe SettingsExit without Saving Upgrading the System Memory Chapter UpgradingUpgrading the Microprocessor Users Notes Appendix a BiosSystem Memory Embedded I/O Miscellaneous Industrial DevicesPCB Construction Control Panel ConnectionsCPU Socket Form FactorData Width System Resource Memory MapDMA Channels Address Range Size Description Decimal HexadecimalAddress hex Description MapOn-board Devices PCI Configuration Space MapBus # Device # Function # Description Interrupts SignalPCI Interrupt Routing Map Device Slave Address Connectors Pin-outEthernet Header J31 Pin# Serial Ports DB9M J36 and J37Pin# Pin# Parallel DB25F J13HDD LED Appendix B Flash Bios Programming Beeps Description Appendix C Disk-On-Chip Users Notes Appendix D On-Board Industrial Devices Watchdog TimerHardware Reset Software ResetPost Code Display AddressCheckpoint Description Code Post Checkpoint CodesTable D-5 Bootblock Recovery Codes Table D-6 Uncompressed Initialization Codes Memory refresh line is toggling. Checking 3Ah Performing the DMA controller 2 base register test next Winbios Adaptor ROM had control and has now returned Table D-7 Bus Checkpoint Codes Bits Description Appendix E On-Board Ethernet Users Notes Page MN-RBXAT-03