Lenovo TD230 manual Replacing the system board battery, Installing the microprocessor

Page 119

9.Hold the new microprocessor by the edges and align the notches 1 on it with the tabs microprocessor socket. Then, install the microprocessor into the socket.

2

in the

Figure 77. Installing the microprocessor

Replacing the system board battery

Attention:

Do not open your server or attempt any repair before reading and understanding the Safety Information and the Warranty and Support Information on the ThinkServer Documentation DVD that came with your product, and “Guidelines” on page 39. To obtain a copy of the publications, go to:

http://www.lenovo.com/support

This section provides instructions on how to replace the system board battery.

Your server has a special type of memory that maintains the date, time, and configuration information for built-in features. The system board battery keeps this information active when you turn off the server.

The system board battery normally requires no charging or maintenance throughout its life; however, no battery lasts forever. If the system board battery fails, the date, time, and configuration information, including passwords, are lost. An error message is displayed when you turn on the server.

Be sure to consider the following information when you replace the battery in the server:

You must replace the battery with a lithium battery of the same type from the same manufacturer.

To avoid possible danger, be sure to read and understand the following safety statement.

After you replace the system board battery, you must reset passwords, system date and time, and reconfigure the server.

Statement 2

CAUTION:

When replacing the lithium battery, use only Part Number 33F8354 or an equivalent type battery recommended by the manufacturer. If your system has a module containing a lithium battery, replace it only with the same module type made by the same manufacturer. The battery contains lithium and can explode if not properly used, handled, or disposed of. Do not:

• Throw or immerse into water

Chapter 5. Replacing FRUs 113

Image 119
Contents ThinkServer TD230 Hardware Maintenance Manual Page ThinkServer TD230 Hardware Maintenance Manual Eighth Edition October Copyright Lenovo 2010 Contents Parts listing, TD230 Types 1027, 1029, 1039, 125 About this manual Safety information在使用本产品之前,请务必先阅读和了解产品附带的文档 DVD 中的多语言安全说明。 제품을 사용하기 전에 제품과 함께 제공되는 문서 DVD의 다국어 안전 지침을 주의 깊게 읽어보십시오Statement 使用本產品之前,請務必閱讀並瞭解產品隨附的文件 DVD 上的多國語言版本安全資訊。ThinkServer TD230 Hardware Maintenance Manual ≥ 18 kg 39.7 lb ≥ 32 kg 70.5 lb ≥ 55 kg 121.2 lb ThinkServer TD230 Hardware Maintenance Manual About this manual Important information about replacing RoHS compliant FRUs About this manual ThinkServer TD230 Hardware Maintenance Manual General information Features and specificationsEasyManage Reliability, availability, and serviceabilitySoftware programs EasyStartupGeneral information ThinkServer TD230 Hardware Maintenance Manual DVD drive problems Troubleshooting tablesIntermittent problems General problemsHard disk drive problems Memory problems Keyboard, mouse, or pointing-device problemsMicroprocessor problems Monitor problems Optional-device problems Power problems Serial port problems Solving power problems Software problemsUniversal Serial Bus USB port problems Solving undetermined problems Solving Ethernet controller problemsSystem event log Diagnostic programs and messagesEvent logs Diagnostic LEDs on the front panel and the system board Front view Locating parts, controls, LEDs, and connectorsOpening the front door LED LED Rear viewRear view of the server Hot-swap hard disk drive status LEDsLocating server components LEDs for the Ethernet connectorsLocating parts on the system board Locating major parts on the system board Jumper block settings Locating diagnostic LEDs on the system boardJumper Block Pin position Description Locating parts, controls, LEDs, and connectors ThinkServer TD230 Hardware Maintenance Manual Basic guidelines GuidelinesHandling static-sensitive devices System reliability guidelinesInspecting for unsafe conditions Working inside the server with the power onGuidelines for trained service technicians Guidelines for servicing electrical equipment Removing the server cover Sliding the server cover to the rear Removing the server cover Removing and reinstalling the front bezelRemoving the front bezel Locking or unlocking the hard disk drive side doorOpening the side door Locking the side door Memory module installation rules Installing or removing a memory moduleInstalling a memory module Opening the retaining clips of the memory slot Removing a memory moduleRemoving the memory module Removing or installing internal drivesRemoving the optical drive Removing the optical driveRemoving the optical drive retainers Installing the optical driveInstalling the optical drive retainers Installing the optical drive Removing a hot-swap hard disk drive Opening the handle of the hot-swap hard disk drive bracket Replacing FRUs Removing the hot-swap hard disk drive Installing a hot-swap hard disk drivePress the blue button To open the side door Opening the handle of the hot-swap hard disk drive bracket Removing the hot-swap hard disk drive bracket Installing the hard disk drive into the bracket Locking the hot-swap hard disk drive in the drive bay Removing a non-hot-swap hard disk driveOpening the side door Replacing FRUs Removing the screws that secure the hard disk drive Installing a non-hot-swap hard disk driveOpening the side door Sliding the non-hot-swap hard disk drive bracket out Securing the hard disk drive in the bracket by screws Sliding the non-hot-swap hard disk drive into the bay Installing or removing a PCI cardInstalling a PCI card Removing a PCI card Installing a PCI cardInstalling the Ethernet card Installing or removing the Ethernet cardRemoving the Ethernet card Installing the RAID 5 key What to do next Removing the RAID 5 keyRemoving the RAID 5 key Installing the TR 500 keyRemoving the TR 500 key Installing the TR 500 keyRemoving the TR 500 key About the RMM3 Installing the RMM3Removing the PCI card slot bracket for the RMM3 connector Installing the RMM3 on the slot bracket Installing the slot bracket with RMM3 Removing the RMM3 Connecting the ribbon cableReplacing FRUs Removing the RAID card Installing, removing, or replacing hardware devicesRemoving or installing the RAID card Installing the ThinkServer RAID 500 Adapter Installing the RAID cardConnecting the mini SAS signal cables Installing the ThinkServer 8708EM2 RAID AdapterConnecting the mini SAS signal cables Installing the ThinkServer 8708EM2 RAID Battery Top view of the battery card assembly Installing the battery card assembly onto the RAID card Connecting the mini SAS cableSAS connectors on the hot-swap hard disk drive backplanes Removing the heat sink and fan assembly Removing or installing the heat sink and fan assemblyReplacing FRUs Heat sink and fan assembly Installing the heat sink and fan assembly Heat sink and fan assembly Removing a front fan Removing or installing a front fanThinkServer TD230 Hardware Maintenance Manual Removing the front fan Installing a front fanThinkServer TD230 Hardware Maintenance Manual Installing the front fan Removing or installing the rear fanRemoving the rear fan Removing the rear fan Installing the rear fanThinkServer TD230 Hardware Maintenance Manual Installing the rear fan Removing or installing the microprocessorRemoving the microprocessor Removing the microprocessorLifting the handle Installing the microprocessorOpening the retainer Installing the microprocessor Replacing the system board batteryHeat to more than 100 C 212 F Repair or disassemble Removing or installing the system boardRemoving the system board Removing the eight screws that secure the system board ThinkServer TD230 Hardware Maintenance Manual Installing the eight screws that secure the system board Installing the system boardReplacing the power supply assembly Removing the screws and the metal clip Removing the power supply assembly Installing the power supply assembly Installing the server cover Completing the parts replacementTurning on the server Connecting the cablesUpdating the server configuration Turning off the server Connecting external devices125 Replaceable server componentsIndex Description CRU part FRU part Number Tier Parts listing, TD230 Types 1027, 1029, 1039, and 1040 Index Description CRU part FRU part Number Tier Index Description CRU part FRU part Number Tier Index Description CRU part FRU part Number Tier CTO Memory module, 4 GB DDR3 Rdimm 1333 MHz models 46U3443 Index Description CRU part FRU part Number Tier Index Description CRU part FRU part Number Tier Windows 2008 SBS SP2 STD 64 bit United Sates models 90Y1174 Index Description CRU part FRU part Number Tier Index Description CRU part FRU part Number Tier Power cords Power cords, Type Power cords, Type 41R3278 Taiwan models CTO 43N9029 Thailand models CTO ThinkServer TD230 Hardware Maintenance Manual ThinkServer RAID 500 Adapter Configuration Utility program Using the Setup Utility programSetup Utility program Ethernet controller configurationIntroduction of the Bios items Starting the Setup Utility programPerformance Configuration on Submenus under the Memory RAS and Performance Submenus under the Serial Port Configuration Submenus under the PCI Configuration Set Administrator Password Set User Password Using passwordsExiting the Setup Utility program RAID controllers Password considerationsSetting, changing, or deleting a password Intel ESRT2 Sata Using the ThinkServer EasyStartup programBefore you use the EasyStartup DVD Setup and configurationRAID information Configuring RAIDTypical operating system installation Configuring the onboard Sata software RAIDDegrade Creating a RAID volumeSelect Easy Configuration OnlineSelect Clear Configuration Initializing the RAID volumeDeleting the RAID volume Connecting the Sata cables Rebuilding the RAID volumeChecking the RAID 1 volume consistency Configuring the Gigabit Ethernet controller Updating the firmware Using the EasyUpdate Firmware Updater programInstalling the ThinkServer EasyManage program Configuring the server ThinkServer TD230 Hardware Maintenance Manual 161 SpecificationsBattery life and data retention time ThinkServer TD230 Hardware Maintenance Manual 163 Before you callUsing other services Purchasing additional services ThinkServer TD230 Hardware Maintenance Manual 167 Appendix C. NoticesProduct recycling and disposal TrademarksImportant notes Particulate contamination Contaminant Limits Battery return programFor the European Union US & Canada OnlyFor California German Ordinance for Work gloss statementIndustry Canada Class a emission compliance statement Appendix C. Notices ThinkServer TD230 Hardware Maintenance Manual 175 IndexRMM3 177 USB Page Part Number 1P P/N