7.Push the hard disk drive to slide the bracket with the hard disk drive into the drive bay until it snaps into position.
Figure 43. Sliding the non-hot-swap hard disk drive into the bay
8.Locate an available
9.To complete the installation, go to “Completing the parts replacement” on page 122. Then, you might need to check the hard disk drive status LEDs to make sure that the hard disk drive is operating correctly. Restart the server for the newly installed drive to be recognized. If the amber hard disk drive status LED is lit continuously, this indicates that the hard disk drive is faulty and must be replaced; if the green hard disk drive status LED is blinking, this indicates that the hard disk drive is operating correctly.
Note: If the server is configured for RAID operation using a RAID controller, you might have to reconfigure the disk arrays after you replace hard disk drives.
Installing or removing a PCI card
This section provides instructions on how to install or remove a PCI card.
The EMI integrity and cooling of the server are protected by having all drive bays and PCI card slots covered or occupied. When you install a drive or PCI card, save the EMC shield or drive bay filler from the drive bay or save the PCI card slot cover in the event that you later remove the device. An unoccupied drive bay or PCI card slot without cover, shield, filler, or any other protection might impact the EMI integrity and cooling of the server, which might result in overheating or component damage.
Note: The PCI cards are extremely sensitive to electrostatic discharge. Make sure that you read and understand “Handling