Lenovo TD230 manual Removing a memory module, Opening the retaining clips of the memory slot

Page 57

4. Open the retaining clips of the memory slot into which you want to install the memory module.

Figure 17. Opening the retaining clips of the memory slot

5.Touch the static-protective package that contains the new memory module to any unpainted metal surface on the outside of the server. Then, remove the new memory module from the package.

6.Position the new memory module over the memory slot. Make sure that the notch 1 on the new memory module is aligned with the key 2 in the memory slot. Then, press the new memory module straight down into the memory slot until the retaining clips close and the new memory module snaps into position.

Note: If there is a gap between the memory module and the retaining clips, the memory module has not been correctly installed. Open the retaining clips, remove the memory module, and then reinstall it into the slot.

Figure 18. Installing the memory module

7. To complete the installation, go to “Completing the parts replacement” on page 122.

Removing a memory module

Attention:

Do not open your server or attempt any repair before reading and understanding the Safety Information and the Warranty and Support Information on the ThinkServer Documentation DVD that came with your product, and “Guidelines” on page 39. To obtain a copy of the publications, go to:

http://www.lenovo.com/support

This section provides instructions on how to remove a memory module.

To remove a memory module, do the following:

Chapter 5. Replacing FRUs 51

Image 57
Contents ThinkServer TD230 Hardware Maintenance Manual Page ThinkServer TD230 Hardware Maintenance Manual Eighth Edition October Copyright Lenovo 2010 Contents Parts listing, TD230 Types 1027, 1029, 1039, 125 About this manual Safety information在使用本产品之前,请务必先阅读和了解产品附带的文档 DVD 中的多语言安全说明。 제품을 사용하기 전에 제품과 함께 제공되는 문서 DVD의 다국어 안전 지침을 주의 깊게 읽어보십시오Statement 使用本產品之前,請務必閱讀並瞭解產品隨附的文件 DVD 上的多國語言版本安全資訊。ThinkServer TD230 Hardware Maintenance Manual ≥ 18 kg 39.7 lb ≥ 32 kg 70.5 lb ≥ 55 kg 121.2 lb ThinkServer TD230 Hardware Maintenance Manual About this manual Important information about replacing RoHS compliant FRUs About this manual ThinkServer TD230 Hardware Maintenance Manual General information Features and specificationsSoftware programs Reliability, availability, and serviceabilityEasyStartup EasyManageGeneral information ThinkServer TD230 Hardware Maintenance Manual DVD drive problems Troubleshooting tablesGeneral problems Hard disk drive problemsIntermittent problems Memory problems Keyboard, mouse, or pointing-device problemsMicroprocessor problems Monitor problems Optional-device problems Power problems Serial port problems Software problems Universal Serial Bus USB port problemsSolving power problems Solving undetermined problems Solving Ethernet controller problemsDiagnostic programs and messages Event logsSystem event log Diagnostic LEDs on the front panel and the system board Front view Locating parts, controls, LEDs, and connectorsOpening the front door LED LED Rear viewRear view of the server Hot-swap hard disk drive status LEDsLocating server components LEDs for the Ethernet connectorsLocating parts on the system board Locating major parts on the system board Jumper block settings Locating diagnostic LEDs on the system boardJumper Block Pin position Description Locating parts, controls, LEDs, and connectors ThinkServer TD230 Hardware Maintenance Manual Basic guidelines GuidelinesHandling static-sensitive devices System reliability guidelinesWorking inside the server with the power on Guidelines for trained service techniciansInspecting for unsafe conditions Guidelines for servicing electrical equipment Removing the server cover Sliding the server cover to the rear Removing the server cover Removing and reinstalling the front bezelRemoving the front bezel Locking or unlocking the hard disk drive side doorOpening the side door Locking the side door Memory module installation rules Installing or removing a memory moduleInstalling a memory module Opening the retaining clips of the memory slot Removing a memory moduleRemoving the memory module Removing or installing internal drivesRemoving the optical drive Removing the optical driveRemoving the optical drive retainers Installing the optical driveInstalling the optical drive retainers Installing the optical drive Removing a hot-swap hard disk drive Opening the handle of the hot-swap hard disk drive bracket Replacing FRUs Removing the hot-swap hard disk drive Installing a hot-swap hard disk drivePress the blue button To open the side door Opening the handle of the hot-swap hard disk drive bracket Removing the hot-swap hard disk drive bracket Installing the hard disk drive into the bracket Locking the hot-swap hard disk drive in the drive bay Removing a non-hot-swap hard disk driveOpening the side door Replacing FRUs Removing the screws that secure the hard disk drive Installing a non-hot-swap hard disk driveOpening the side door Sliding the non-hot-swap hard disk drive bracket out Securing the hard disk drive in the bracket by screws Sliding the non-hot-swap hard disk drive into the bay Installing or removing a PCI cardInstalling a PCI card Removing a PCI card Installing a PCI cardInstalling the Ethernet card Installing or removing the Ethernet cardRemoving the Ethernet card Installing the RAID 5 key What to do next Removing the RAID 5 keyRemoving the RAID 5 key Installing the TR 500 keyRemoving the TR 500 key Installing the TR 500 keyRemoving the TR 500 key About the RMM3 Installing the RMM3Removing the PCI card slot bracket for the RMM3 connector Installing the RMM3 on the slot bracket Installing the slot bracket with RMM3 Removing the RMM3 Connecting the ribbon cableReplacing FRUs Installing, removing, or replacing hardware devices Removing or installing the RAID cardRemoving the RAID card Installing the ThinkServer RAID 500 Adapter Installing the RAID cardConnecting the mini SAS signal cables Installing the ThinkServer 8708EM2 RAID AdapterConnecting the mini SAS signal cables Installing the ThinkServer 8708EM2 RAID Battery Top view of the battery card assembly Installing the battery card assembly onto the RAID card Connecting the mini SAS cableSAS connectors on the hot-swap hard disk drive backplanes Removing the heat sink and fan assembly Removing or installing the heat sink and fan assemblyReplacing FRUs Heat sink and fan assembly Installing the heat sink and fan assembly Heat sink and fan assembly Removing a front fan Removing or installing a front fanThinkServer TD230 Hardware Maintenance Manual Removing the front fan Installing a front fanThinkServer TD230 Hardware Maintenance Manual Installing the front fan Removing or installing the rear fanRemoving the rear fan Removing the rear fan Installing the rear fanThinkServer TD230 Hardware Maintenance Manual Installing the rear fan Removing or installing the microprocessorRemoving the microprocessor Removing the microprocessorLifting the handle Installing the microprocessorOpening the retainer Installing the microprocessor Replacing the system board batteryRemoving or installing the system board Removing the system boardHeat to more than 100 C 212 F Repair or disassemble Removing the eight screws that secure the system board ThinkServer TD230 Hardware Maintenance Manual Installing the eight screws that secure the system board Installing the system boardReplacing the power supply assembly Removing the screws and the metal clip Removing the power supply assembly Installing the power supply assembly Installing the server cover Completing the parts replacementConnecting the cables Updating the server configurationTurning on the server Turning off the server Connecting external devices125 Replaceable server componentsIndex Description CRU part FRU part Number Tier Parts listing, TD230 Types 1027, 1029, 1039, and 1040 Index Description CRU part FRU part Number Tier Index Description CRU part FRU part Number Tier Index Description CRU part FRU part Number Tier CTO Memory module, 4 GB DDR3 Rdimm 1333 MHz models 46U3443 Index Description CRU part FRU part Number Tier Index Description CRU part FRU part Number Tier Windows 2008 SBS SP2 STD 64 bit United Sates models 90Y1174 Index Description CRU part FRU part Number Tier Index Description CRU part FRU part Number Tier Power cords Power cords, Type Power cords, Type 41R3278 Taiwan models CTO 43N9029 Thailand models CTO ThinkServer TD230 Hardware Maintenance Manual Setup Utility program Using the Setup Utility programEthernet controller configuration ThinkServer RAID 500 Adapter Configuration Utility programIntroduction of the Bios items Starting the Setup Utility programPerformance Configuration on Submenus under the Memory RAS and Performance Submenus under the Serial Port Configuration Submenus under the PCI Configuration Using passwords Exiting the Setup Utility programSet Administrator Password Set User Password Password considerations Setting, changing, or deleting a passwordRAID controllers Intel ESRT2 Sata Using the ThinkServer EasyStartup programBefore you use the EasyStartup DVD Setup and configurationTypical operating system installation Configuring RAIDConfiguring the onboard Sata software RAID RAID informationSelect Easy Configuration Creating a RAID volumeOnline DegradeInitializing the RAID volume Deleting the RAID volumeSelect Clear Configuration Rebuilding the RAID volume Checking the RAID 1 volume consistencyConnecting the Sata cables Configuring the Gigabit Ethernet controller Using the EasyUpdate Firmware Updater program Installing the ThinkServer EasyManage programUpdating the firmware Configuring the server ThinkServer TD230 Hardware Maintenance Manual Specifications Battery life and data retention time161 ThinkServer TD230 Hardware Maintenance Manual 163 Before you callUsing other services Purchasing additional services ThinkServer TD230 Hardware Maintenance Manual 167 Appendix C. NoticesTrademarks Important notesProduct recycling and disposal Particulate contamination Contaminant Limits Battery return programFor the European Union US & Canada OnlyGerman Ordinance for Work gloss statement Industry Canada Class a emission compliance statementFor California Appendix C. Notices ThinkServer TD230 Hardware Maintenance Manual 175 IndexRMM3 177 USB Page Part Number 1P P/N
Related manuals