Power Service Check
| FRU OR PROCEDURE | ACTION |
|
|
|
1 | Power Supply | Disconnect J11 from the system |
|
| board and check the following volt- |
|
| ages on the power supply cable: |
|
| |
|
| |
|
| If you do not have correct voltage, |
|
| replace the power supply. Be sure to |
|
| unplug the machine before you recon- |
|
| nect the power supply to the system |
|
| board. |
|
|
|
2 | Operator Panel | With the power button depressed, |
|
| check for 0 ohms at |
|
| front of the operator panel connector. |
|
| If the reading is incorrect, check the |
|
| operator panel cable for continuity. If |
|
| the cable has continuity, replace the |
|
| operator panel. |
|
|
|
3 | Print Head Cable | Turn off the printer. Disconnect one of |
| Simm Card | the listed components and turn on the |
| Parallel Cable | printer. Look for a symptom change. |
|
| Check the failing part for shorts and |
|
| replace as necessary. Repeat this |
|
| procedure for the remaining listed |
|
| parts. |
|
|
|
4 | System Board | If the symptom has not changed, |
|
| replace the system board. |
|
|
|
Diagnostic Information 19