Operator Panel Service Check
| FRU OR PROCEDURE | ACTION |
|
|
|
1 | Power Supply | Disconnect J11 from the system |
|
| board and check the following volt- |
|
| ages on the power supply cable: |
|
| |
|
| |
|
| If you do not have correct voltage, |
|
| replace the power supply. Be sure to |
|
| unplug the machine before you recon- |
|
| nect the power supply to the system |
|
| board. |
|
|
|
2 | System Board | Turn the printer on. Check for +5 V dc |
|
| at test point CE/TP near the operator |
|
| panel connector on the system board |
|
|
|
3 | Operator Panel Cover | The operator panel cover actuates |
|
| the operator panel sensor on the |
|
| operator panel. Check the cover for |
|
| any broken parts. Check the operator |
|
| panel sensor for dirt. |
|
|
|
4 | Operator Panel Card | Check the operator panel cable for |
| Operator Panel Cable | continuity. If the cable is good, |
|
| replace the operator panel. If the |
|
| symptom remains, replace the sys- |
|
| tem board. |
|
|
|
Diagnostic Information 13