Chapter 6 Diagnostics

Vmux-2100Installation and Operation Manual

 

 

Diagnostics

1.Inject Tone Test

2.Local Loop Test

3.Remote Loop Test

4.Display Active test

5.Ping

@ - Db Update; # - Db Undo ESC-prev.menu; !-main menu; &-exit

Figure 6-2. Diagnostics Menu

2.From the Diagnostic menu, choose Inject Tone Test. The Inject Tone Test menu appears (see Figure 6-3).

Inject Tone Test

 

 

 

1.

Slot

 

>

(Slot 1)

2.

Port

 

>

(Port 1)

3.

Timeslot

[1 - 31]

(1)

4.

Direction

 

>

(Local)

5.

Time Out(seconds, 0=forever)

[0 - 60]... (0)

6.

Activate

 

 

 

@ - Db Update; # - Db Undo ESC-prev.menu; !-main menu; &-exit

Figure 6-3. Inject Tone Menu

3.From the Inject Tone Test menu, perform the following steps to complete the tone injection activation:

Select a desired slot.

Select a desired E1/T1.

Select a timeslot for the tone injection. Specify direction of the tone injection:

Local (towards the local PBX, see Figure 6-1)

Define the tone injection timeout (period of time after which the tone injection stops automatically):

0 seconds (forever) to 60 seconds

Activate the tone injection by typing 6, and selecting Yes from the displayed menu.

Repeat the procedure for all timeslots that you intend to test.

Note You can display information on all tests running at a time by selecting Display Active Tests from the Diagnostics menu.

6-2

Tone Injection

Page 82
Image 82
RAD Data comm Vmux-2100 Voice Trunking Gateway operation manual Diagnostics Menu