Chapter 3 OperationVmux-2100Installation and Operation Manual

Table 3-1. Vmux-2100 LEDs (Cont.)

Name

Function

Location

 

 

 

LINK (green)

ON – Good link integrity

Ethernet main link

 

 

connector

 

 

 

ACT (yellow)

Blinks according to the Ethernet traffic

Ethernet main link

 

 

connector

 

 

 

LOC (red)

ON – Local sync loss occurred

E1 main link and voice

 

 

port connector

 

 

 

REM (red)

ON – Remote sync loss occurred

E1 main link and voice

 

 

port connector

 

 

 

RED (red)

ON – Red alarm is received

T1 main link and voice

 

 

port connector

 

 

 

YEL (yellow)

ON – Yellow alarm is received

T1 main link and voice

 

 

port connector

 

 

 

3.2 Operating Vmux-2100

Turning On Vmux-2100

To turn on Vmux-2100:

Connect the power cord(s) to the mains.

The PWR1(2) indicator lights up and remains lit as long as Vmux-2100 receives power.

Normal Indications

Table 3-2shows the correct status of the indicators a few seconds after power-up.

Table 3-2. Vmux-2100 Indicator Status

Indicator Status

PWR1/PWR2 On

TESTOff

ALMOn

LOff

ROff

If the above LED indications do not appear following initial power turn-on, refer to Chapter 5 for the diagnostic test instructions.

Turning Off Vmux-2100

To turn off Vmux-2100:

Remove the power cord from the power source.

3-2

Operating Vmux-2100

Page 38
Image 38
RAD Data comm operation manual Operating Vmux-2100, Turning On Vmux-2100, Normal Indications, Turning Off Vmux-2100