Chapter 7 Monitoring and Statistics CollectionVmux-2100Installation and Operation Manual
Table 7-1. Vmux-2100 Alarms (Cont.)
ID Code | Terminal Message | Description |
| Severity |
|
|
|
| |
43 | POWER SUPPLY NO. 2 | Power supply 2 has been removed from its slot | Major | |
| WAS REMOVED |
|
|
|
|
|
|
|
|
44 | FAN No.1 FAILURE | Fan 1 failure has been detected |
| Major |
|
|
|
|
|
45 | FAN No.2 FAILURE | Fan 2 failure has been detected |
| Major |
|
|
|
|
|
46 | FAN No.3 FAILURE | Fan 3 failure has been detected |
| Major |
|
|
|
|
|
47 | FAN No.4 FAILURE | Fan 4 failure has been detected |
| Major |
|
|
|
| |
67 | MAIN LINK OVERFLOW | The required transmit bandwidth exceeds the | Major | |
|
| actual main link throughput |
|
|
|
|
|
| |
78 | TCP connection between Group 1 of slot X and the | Major | ||
| WITH GR1 | main module has been lost |
|
|
|
|
|
| |
79 | TCP connection between Group 2 of slot X and the | Major | ||
| WITH GR2 | main module has been lost |
|
|
|
|
|
| |
80 | BPV ERROR HAS | A bipolar violation error has been detected E1/T1 | Event | |
| OCCURRED | port |
|
|
|
|
|
|
|
81 | EXCESSIVE ERROR | ⋅ | Major | |
| RATION | The bit error rate of the port exceeds 1 | 10 |
|
|
|
|
| |
|
|
|
|
|
82 | ALARM INDICATION | AIS is being detected at the E1/T1 port |
| Major |
| SIGNAL |
|
|
|
|
|
|
|
|
83 | EXCESSIVE BIPOLAR | Excessive BPVs at the E1/T1 port |
| Major |
| VIOLATION |
|
|
|
|
|
|
|
|
84 | T1/E1 FRAME SLIP HAS | A frame slip at the E1/T1 port |
| Event |
| OCCURRED |
|
|
|
|
|
|
|
|
87 | T1/E1 SIGNAL LOSS | Loss of input signal at the E1/T1 port |
| Major |
|
|
|
| |
88 | AIS RED ALARM | Local loss of frame synchronization at the T1 port | Major | |
|
| caused by AIS condition |
|
|
|
|
|
| |
89 | LOC SYNC LOSS | Local loss of frame synchronization at the E1/T1 | Major | |
| (RED ALARM) | port |
|
|
|
|
|
| |
90 | REM SYNC LOSS | Remote loss of frame synchronization at the E1/T1 | Major | |
| (YELLOW ALARM) | port |
|
|
|
|
|
| |
92 | NETWORK LLB | Line loopback command is received from the | Minor | |
|
| network at the T1 port |
|
|
|
|
|
| |
93 | NETWORK PLB | Payload loopback command is received from the | Minor | |
|
| network at the T1 port |
|
|
|
|
|
| |
97 | LOCAL MULTIFRAME | Local loss of multiframe synchronization at the E1 | Minor | |
| ALARM | port |
|
|
|
|
|
| |
98 | REMOTE MULTIFRAME | Remote loss of multiframe synchronization at the | Minor | |
| ALARM | E1 port |
|
|
|
|
|
| |
100 | CRC ERROR OCCURRED | Minor | ||
|
|
|
| |
195 | BUNDLE IS OOS | Bundle is out of service due to network problems | Major | |
|
|
|
|
|