7. From the Time Slot Configuration menu, configure the following parameters:

Define timeslot(s) to configure by choosing Update from Time Slot to select the first timeslot and then choosing To Time Slot to select the last timeslot.

Select a timeslot type by choosing Type: N.C. (timeslot is not connected) Voice (timeslot transmits voice)

HDLC (timeslot transmit data, for example, signaling information).

Assign a timeslot to a bundle by choosing Bundle, and selecting a bundle number.

Specify a destination port by choosing Destination Port ID, and entering a port number.

Define the destination timeslots to which the local timeslots are routed. You only have to specify a starting timeslot; (the rest of the destination timeslots are configured automatically according to the number of timeslots previously set by the Update from Time Slot/To Time Slot parameters).

Save the changes that you made to the timeslots by choosing Update Time Slot.

Note Make sure to save the changes that you have made to the timeslot configuration.

8.Check the resulting timeslot configuration by choosing Display Time Slots from the Distribution Of Framer Time Slots menu (see Figure 4-37).

The Display Time Slots screen appears (see Figure 4-39).

Display

Time Slots

 

 

Ts#

Type

Bundle

Dest Port

Dest Ts

1

N.C

0

1

0

2

Voice

1

4

1

3

Voice

1

4

2

v 4

Voice

1

4

3

5

Voice

1

4

4

6

N.C

0

1

0

7

N.C

0

1

0

8

N.C

0

1

0

9

N.C

0

1

0

10

N.C

0

1

0

>

@ - Db Update; # - Db Undo ESC-prev.menu; !-main menu; &-exit

Figure 4-39. Display Time Slots Screen

Configuring Main Link and Voice E1/T1 Ports

4-31

Page 73
Image 73