Chapter 7 Monitoring and Statistics Collection

Vmux-2100Installation and Operation Manual

 

 

Sanity Error and Warning List

Table 7-2lists in alphabetical order all sanity errors and warnings generated by Vmux-2100.

Table 7-2. Sanity Errors and Warnings

Display

Type

Description

 

 

 

BUNDLE IS NOT

Warning

A timeslot is assigned to a bundle which is not connected

CONNECTED

 

 

 

 

 

CARD DOES NOT EXIST IN

Warning

A voice card configured in the database is missing from a slot

SLOT

 

 

 

 

 

CARD EXISTS IN SLOT

Warning

A voice card installed in a Vmux-2100 slot is not configured in

 

 

the database (the Hub menu).

 

 

 

CARD TYPE MISMATCH

Warning

A mismatch between a voice card or main link card installed in

 

 

Vmux-2100 and its type configured in the database.

 

 

 

CCS TS NOT RELATED TO

Error

At least two timeslots of the E1/T1 port with the CCS signaling

THE SAME BUNDLE

 

are assigned to different bundles. To avoid it, assign all

 

 

timeslots of the same E1/T1 port with the CCS signaling to the

 

 

same bundle.

 

 

 

CCS TS NOT RELATED TO

Error

At least two timeslots of the E1/T1 port with the CCS signaling

THE SAME SLOT

 

are assigned to different destination slots. To avoid it, assign all

 

 

timeslots of the same E1/T1 port with the CCS signaling to the

 

 

same destination slot.

 

 

 

CODER PROBLEM

Error

Conflict in the DSP capacity and timeslot configuration. Since

 

 

each DSP handles six timeslots, every six consecutive timeslots

 

 

must be configured to use the same voice compression

 

 

method.

 

 

 

CONNECTIVITY VALUES

Error

Connectivity values of all bundles which belong to the same

MUST BE THE SAME FOR ALL

 

group (have the same source IP) must be the same.

GROUP BUNDLES

 

 

 

 

 

DISCONNECT BUNDLE

Error

Voice compression type was changed for a connected bundle.

BEFORE CHANGING CODER

 

A mismatch between a voice compression type of an active

RATE

 

local bundle and that of the destination bundle may cause

 

 

problems at a DSP. To avoid this, do the following:

 

 

1. Disconnect a bundle of the local Vmux-2100.

 

 

2. Disconnect destination bundle of the remote Vmux-2100.

 

 

3. Change the voice compression method for both bundles.

 

 

4. Reconnect the bundles.

 

 

 

DOUBLE ROUTE

Error

More than one timeslot is connected to the same destination

 

 

timeslot

 

 

 

E1/T1 NOT THE SAME FRAME

Error

E1/T1 ports of the same group are configured to the different

TYPE

 

framing modes

 

 

 

EMPTY ADMINISTRATOR

Error

The last administrator account is deleted from the user

LIST

 

database.

 

 

 

EXTERNAL NOT

Warning

A timeslot is assigned to an E1/T1 port which is not connected

CONNECTED

 

 

 

 

 

7-6

Sanity Checks

Page 92
Image 92
RAD Data comm Vmux-2100 Sanity Error and Warning List, Sanity Errors and Warnings, Display Type Description