Chapter 7 Monitoring and Statistics Collection

 

 

Working with Permanent Buffer

The permanent buffer is represented by the Alarm Status screen.

To access the Alarm Status screen:

From the Display menu (see Figure 7-2), choose Display Alarm Status. Vmux-2100 displays the permanent alarm buffer (see Figure 7-4).

(047)

FAN No.

4

FAILURE

MAJOR

(047)

FAN No.

4

FAILURE

OFF

(20)

INTERNAL ERROR

Event

Press ‘y’ To Continue...

Press ‘n’ To Stop.

@ - Db Update; # - Db Undo ESC-prev.menu; !-main menu; &-exit

Figure 7-4. Permanent Buffer (Alarm Status Screen)

To delete inactive alarms from the permanent buffer:

1.From the Status menu (see Figure 7-1), choose Clear. The Clear menu appears.

2.Confirm the alarm deletion by choosing Clear all Alarms.

Vmux-2100 deletes all alarms in the OFF state and events from the permanent buffer.

Table 7-1lists the Vmux-2100 alarms according to their identification codes.

Table 7-1. Vmux-2100 Alarms

ID Code

Terminal Message

Description

Severity

 

 

 

 

18

DB UPDATE OCCURRED

Vmux-2100 database has been updated

Event

 

 

 

 

20

INTERNAL ERROR

Software error

Event

Note: The INTERNAL ERROR alarm is used for software debugging. To receive detailed description of each internal alarm, enable ‘Open Internal Alarms’ from the System menu (Main menu > Configuration > System > Open Internal Alarms).

21

MODULE WAS REMOVED

A voice module installed in the specified slot has

Event

 

 

been removed

 

 

 

 

 

22

MODULE WAS INSERTED

A voice module has been inserted from into a slot

Event

 

 

 

 

40

POWER SUPPLY No. 1

Power supply 1 failure has been detected

Major

 

FAILURE

 

 

 

 

 

 

41

POWER SUPPLY No. 2

Power supply 2 failure has been detected

Major

 

FAILURE

 

 

 

 

 

 

42

POWER SUPPLY NO. 1

Power supply 1 has been removed from its slot

Major

 

WAS REMOVED

 

 

 

 

 

 