Vmux-2100Installation and Operation Manual

Chapter 5 Configuring Vmux-2100 for a Typical Application

 

 

7.Display the Signal Profile Configuration menu, enter a desired signaling system profile number (1) and configure it according to the system used by the PBX connected to the V-4E1 card (Main Menu > Configuration > System > Management > Signaling Configuration> Signaling Profile Configuration).

8.Display the Hub menu and enter the existing main link card (M-IPE1) and the voice card (V-4E1) into the unit’s database (Main Menu > Configuration > Hub).

Configuring E1 Main Link Parameters

Configuring the E1 main link parameters:

1.Display the Main Link menu, and configure the E1 main link parameters to the following values (Main Menu > Configuration > Card > Main Board >

E1 Parameters > Main Link 1): Connect – Yes

Frame – G.732N Restoration – CCITT Clock Source – Lbt Interface Type – Dsu Idle Code – 7E.

2.Display the Time Slot Table menu and assign the timeslots to carry data

(Main Menu > Configuration > Card > Main Board > E1 Parameters > Time Slot Table):

Yes – connected (assigned)

No – disconnected (not assigned).

Configuring Voice Card Parameters

Configuring the voice card parameters:

1.Display the Group 1 menu, and assign the 172.17.15.11 IP address to the group 1 (Main Menu > Configuration > Card > Slot 1 > Group 1).

2.Display the Bundle Configuration menu, and add bundle 1 to the system (Main Menu > Configuration > Card > Slot 1 > Group 1 > Bundles Parameters > Bundle Configuration).

3.Display the Edit Bundle menu, and configure the group 1 bundle 1 parameters to the following values (Main Menu > Configuration > Card > Slot 1 > Group 1 > Bundles Parameters > Bundle Configuration > Edit Bundle):

Connect – Yes Function – TDMoIP

Max Bytes In Multiplexed Frame – 500 Destination IP – 172.17.15.21 Destination Bundle – 1

Packetizing Interval – 30 Coder/Rate – G.723.1/6.4 Fax/Modem – Enable at 9.6 kbps.