Chapter 7 Monitoring and Statistics Collection

Vmux-2100Installation and Operation Manual

 

 

Status

1.Display

2.Clear

3.Display Sanity

@ - Db Update; # - Db Undo ESC-prev.menu; !-main menu; &-exit

Figure 7-1. Status Menu

3. From the Status menu, choose Display.

The Display menu appears (see Figure 7-2).

Display

1.Display All Alarms

2.Display & Clear Alarms

3.Display Alarm Status

@ - Db Update; # - Db Undo ESC-prev.menu; !-main menu; &-exit

Figure 7-2. Display Menu

4.From the Display menu, choose Display All Alarms to view the alarms. Vmux-2100 displays the temporary alarm buffer (see Figure 7-3).

(047)

FAN No.

4

FAILURE

MAJOR

10-03-2001

01:50:16

(047)

FAN No.

4

FAILURE

OFF

10-03-2001

01:50:1

(20)

INTERNAL ERROR

Event

10-03-2001

01:48:15

Press ‘y’ To Continue...

Press ‘n’ To Stop.

@ - Db Update; # - Db Undo ESC-prev.menu; !-main menu; &-exit

Figure 7-3. Temporary Buffer (Display All Alarms Screen)

The display includes alarm identification code, its severity, status, and generation date and time.

The active alarms are indicated

To delete alarms from the temporary buffer:

From the Display menu, choose Display & Clear Alarms to view and then delete the current alarms.

Vmux-2100 displays the current alarms and deletes them from the buffer when the user exits the screen.

7-2 Alarms

Page 88
Image 88