Chapter 1 Introduction

Vmux-2100Installation and Operation Manual

 

 

 

T1 Main Link

Number of Links

Two (one redundant)

 

Data Rate

1.544 Mbps

 

Standards

ANSI T1.403, AT&T TR-62411, ITU-T Rec. G.703

 

Line Code

AMI

 

Zero Suppression

B8ZS

 

Framing

SF, ESF, transparent

 

Timing

Internal or loopback

 

Statistics

Full statistical diagnostics capability according to

 

 

ANSI T1.403-1989

 

 

Local support of ESF diagnostics according to

 

 

AT&T PUB 54016

 

Receive Signal Level

0 to -36 dB with CSU

 

 

0 to -30 dB without CSU

 

Transmit Signal Level

0, -7.5, -15, or -22.5 dB with CSU

 

 

±2.7V (±10%) at 0–655 ft without CSU

 

Jitter Performance

Per AT&T TR-62411

 

Line Impedance

100, balanced

E1 Voice

Ports per Module

Two or four

Ports

 

 

 

Data Rate

2.048 Mbps per port

 

Standards

ITU-T Rec. G.703, G.704, G.706, G.732, G.823

 

Framing

G.732S and G.732N with or without CRC-4, in

 

 

compliance with ITU-T Rec. G.703, G.704, G.732

 

 

requirements

 

Line Code

HDB3

 

Receive Signal Level

0 to -43 dB with LTU

 

 

0 to -12 dB without LTU

 

Transmit Signal Level

±3V (±10%)

 

Jitter Performance

Per ITU-T G.823

 

Line Impedance

120, balanced

 

Connector (per port)

RJ-45, 8-pin

T1 Voice

Ports per Module

Two or four

Ports

 

 

 

Data Rate

1.544 Mbps per port

 

Standards

ANSI T1.403, ITU-T Rec. G.703

1-12

Technical Specifications