Chapter 4 Management from a Terminal

Vmux-2100Installation and Operation Manual

 

 

Idle Code (code transmitted to fill unused timeslots in the E1 frames): 00 to ff.

4.From the E1 Parameters menu, choose Time Slot Table to assign the E1 main link to carry the user data (and idle code).

The Time Slot Table menu appears.

Timeslots that are connected (assigned to carry data) are marked Yes; timeslots that are disconnected (not assigned) are marked No.

Time Slot Table

 

 

 

 

 

 

 

 

 

 

 

Ts#

1

2

3

4

5

6

7

8

9

10

11

12

 

Yes

Yes

Yes

No

No

No

No

No

No

No

No

No

Ts#

13

14

15

16

17

18

19

20

21

22

23

24

 

No

No

No

No

Yes

No

No

No

No

No

No

No

Ts#

25

26

27

28

29

30

31

 

 

 

 

 

 

No

No

No

No

No

No

No

 

 

 

 

 

1. No

2. Yes

>

@ - Db Update; # - Db Undo ESC-prev.menu; !-main menu; &-exit

Figure 4-26. Time Slot Table (for E1 Link)

5.From the Time Slot Table, toggle between timeslots by pressing <Tab>, and assign the timeslot(s) that are to carry data by entering Yes. To disconnect a timeslot, enter No.

Note Since Vmux-2100 uses only one E1 main link at a time, the timeslot mapping is applicable also for the inactive E1 port.

Configuring the T1 Main Link Port

The procedure for configuring the T1 main link port is similar to the procedure described above for configuring the E1 main link port. The following parameters, which are configured via the Main Link 1 or Main Link 2 menu (see Figure 4-27), are unique to the T1 links:

4-22 Configuring Main Link and Voice E1/T1 Ports

Page 64
Image 64
RAD Data comm Vmux-2100 Voice Trunking Gateway Configuring the T1 Main Link Port, Time Slot Table for E1 Link