Chapter 5 Configuring Vmux-2100 for a Typical Application

Vmux-2100Installation and Operation Manual

 

 

4.Display the E1 Parameters menu, and set the E1 port of group 1 to the following values (Main Menu > Configuration > Card > Slot 1 > Group 1 > External 1 > E1 Parameters):

Connect – Yes

Frame – G.732S

Restoration – CCITT

Clock Source – Lbt

Interface Type –Dsu

Idle Code – 7E

Signaling – CAS

Profile – 1.

5.Display the Time Slot Configuration menu, and configure the timeslots belonging to the external port 1 of group 1 (Main Menu > Configuration > Card > Slot 1 > Group 1 > External 1 >

Distribution Of Framer Time Slots > Time Slot Configuration): Update from Time Slot – 1

To Time Slot – 31 Type – Voice Bundle – 1 Destination Port ID – 1 Destination Time Slot ID – 1.

Note Vmux-2100 displays timeslot 16 as ‘Not Connected’ (NC), because it carries CAS signaling information.

6.Update the timeslot database from the Time Slot Configuration menu.

7.Repeat step 4 to step 6 for the external port 2 of group 1, except for the following:

Assign 2 to the Destination Port ID for the timeslots in step 5.

8.Display the Group 2 menu, and assign the 172.17.15.12 IP address to the group 2 (Main Menu > Configuration > Card > Slot 1 > Group 2).

9.Repeat step 3 to step 6 for the external port 1 of group 2, except for the following:

Assign destination IP 172.17.15.21 to the bundle 1 in step 2 Assign 3 to the Destination Port ID for the timeslots in step 5.

10.Repeat step 4 to step 6 for the external port 2 of group 2, except for the following:

Assign 4 to the Destination Port ID for the timeslots in step 5.

Figure 5-2summarizes the external E1 bundle and timeslot configuration of the local and remote units.

5-4

Configuring Vmux-2100 for Operation with CAS Signaling