Chapter 4 Management from a Terminal

Vmux-2100Installation and Operation Manual

 

 

To configure the keep-alive suppression rate:

1.From the Signaling Configuration menu (see Figure 4-15), choose SS7 Keep-Alive Suppression Rate.

The SS7 Keep-Alive Suppression Rate menu appears (see Figure 4-18).

SS7 Keep-Alive Suppression Rate (0%)

1.0% - No Suppression / Not SS7

2.10%

3.20%

4.30%

5.40%

6.50%

7.60%

8.70%

9.80%

10.90%

>

Please select item <1 to 10> @ - Db Update; # - Db Undo

ESC-prev.menu; !-main menu; &-exit

Figure 4-18. SS7 Keep-Alive Suppression Rate Menu

2.From the SS7 Keep-Alive Suppression Rate menu, type a number corresponding to the desired value, and press <Enter>.

Assigning a Name to Vmux-2100

The Vmux-2100 management software allows you to assign a name to the unit to distinguish it from the other devices installed in your system.

To assign a name:

3.From the Management menu (see Figure 4-6), choose Host Mux Name

4.Enter a name for the Vmux-2100, and press <Enter>.

Assigned name appears at the top of each terminal screen.

Setting Date and Time

You can set the time for the Vmux-2100 internal real-time clock.

To set date and time:

1.From the System menu (see Figure 4-5), choose Date & Time Update. The Date & Time Update menu appears (see Figure 4-19).