98 High Availability Software for the Intel® NetStructureTM ZT 4901 Technical Product Specification
Demonstration Utilities
•Enable Switchover Request Notification
•Enable Unsafe Switchover Notification
•Disable Notification
10.1.3 IPMI InterfaceThe IPMI interface is an important element of the RSS system architecture. It is used extensively
for system management and inter-chassis communications:
•Access
•Configure
•System management
•Fault configuration and managem ent
•Isolation strategies
•Inter-host communications
The IPMI interface exercises the following IPMI API, fault configuration and system management
functions:
Get Temperature Sensor Status/Thresholds - Gets the temperature sensor status and readings.
Set Temperature Sensor Status/Thresholds - Sets the temperature sensor status and thresholds.
Get Voltage Sensor Status/Thresholds - Gets the voltage sensor status and readings.
Set Voltage Sensor Status/Thresholds - Sets the voltage sensor status and thresholds.
10.1.3.1 Fault Configuration
The RHDemo performs the following fault configuration activities:
•Upper/Lower non-critical threshold
•Upper/Lower critical threshold
•Upper/Lower non-recoverable threshold
10.1.3.2 Isolation Strategy
The RHDemo executes one of the following isolation strategies, depending on the occurring event:
•Alert
•Power Off
•Reset
•Power Cycle
•OEM Action
•Diagnostic Interrupt (NMI)