System Management
•Upper/Lower critical threshold
•Upper/Lower
Each range can be set independently for each sensor and the ranges can overlap. This area of configuration is used only to trigger events. These events appear in the System Event Log. Platform Event Filtering (PEF) determines the actions that occur as a result of these events. Only the Upper/Lower
4.2.2Isolation Strategies
The BMC handles the following event actions in its PEF Table:
•Alert
•Power Off
•Reset
•Power Cycle
•Diagnostic Interrupt (NMI)
These options can be set independently for each event.
Support for a Handover action allows the takeover / handover process to occur from the BMC. This action triggers the CompactPCI Interface Controller (CIC) to initiate the handover sequence. A virtual RH channel facilitates this switchover request.
Table 1. Channel Definitions for ZT 5524
Channel # | Description |
|
|
0x0 | IPMB 0 |
|
|
0x1 | EMP |
|
|
0x2 | ICMB |
|
|
0x3 | PCI |
|
|
0x4 | SMM |
|
|
0x5 | RH Virtual Channel |
|
|
0x 6 | LAN Interface 2 |
|
|
0x 7 | LAN Interface 1 |
|
|
0x 8 | IPMB 1 |
|
|
0x 9 | RESERVED |
|
|
0xA | RESERVED |
|
|
0xB | RESERVED |
|
|
0xC | Internal |
|
|
0xD | RESERVED |
|
|
0xE | Self |
|
|
0xF | SMS |
|
|
High Availability Software for the Intel® NetStructureTM ZT 4901 Technical Product Specification | 27 |