Fluke 2680A, 2686A manual Limited Warranty and Limitation of Liability

Page 2

Limited Warranty and Limitation of Liability

Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is one year and begins on the date of shipment. Parts, product repairs and services are warranted for 90 days. This warranty extends only to the original buyer or end-user customer of a Fluke authorized reseller, and does not apply to fuses, disposable batteries or to any product which, in Fluke’s opinion, has been misused, altered, neglected, contaminated, or damaged by accident or abnormal conditions of operation or handling.

Fluke warrants that software will operate substantially in accordance with its functional specifications for 90 days and that it has been properly recorded on non-defective media. Fluke does not warrant that software will be error free or operate without interruption. The software is neither intended nor warranted for use in medical or any other applications where human safety may be a concern.

Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is available only if product is purchased through a Fluke authorized sales outlet or Buyer has paid the applicable international price. Fluke reserves the right to invoice Buyer for importation costs of repair/replacement parts when product purchased in one country is submitted for repair in another country.

Fluke’s warranty obligation is limited, at Fluke’s option, to refund of the purchase price, free of charge repair, or replacement of a defective product which is returned to a Fluke authorized service center within the warranty period.

To obtain warranty service, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to that service center, with a description of the difficulty, postage and insurance prepaid (FOB Destination). Fluke assumes no risk for damage in transit. Following warranty repair, the product will be returned to Buyer, transportation prepaid (FOB Destination). If Fluke determines that failure was caused by neglect, misuse, contamination, alteration, accident or abnormal condition of operation or handling, including overvoltage failures caused by use outside the product’s specified rating, or normal wear and tear of mechanical components, Fluke will provide an estimate of repair costs and obtain authorization before commencing the work. Following repair, the product will be returned to the Buyer transportation prepaid and the Buyer will be billed for the repair and return transportation charges (FOB Shipping Point).

THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES AND/OR PROFITS, INCLUDING LOSS OF DATA, ARISING FROM ANY CAUSE OR THEORY.

Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not apply to every buyer. If any provision of this Warranty is held invalid or unenforceable by a court or other decision-maker of competent jurisdiction, such holding will not affect the validity or enforceability of any other provision.

Fluke Corporation

Fluke Europe B.V.

P.O. Box 9090

P.O. Box 1186

Everett, WA 98206-9090

5602 BD Eindhoven

U.S.A.

The Netherlands

2/02

Image 2
Contents 2680A/2686A Limited Warranty and Limitation of Liability Safety Information Interference InformationSafety Terms in this Manual Xwwarning Xwwarning Do not Operate in Explosive Atmospheres General Specifications Characteristic Additional Safety InformationSpecification Page Table of Contents 2680A/2686A Getting Started IntroductionContacting Fluke Additional InformationReviewing and Setting the Base Channel Number Configuring the 268XAReviewing and Setting the Base Channel Number Examples for Reviewing and Setting the BCN Reviewing and Setting the Line Frequency Reviewing and Setting the Line FrequencyExamples for Reviewing and Setting the Line Frequency Reviewing and Setting the Network Type Reviewing and Setting the Network TypeExamples for Reviewing and Setting the Network Type Reviewing and Setting the Network Type to General Communications display for reviewing the network type IP address display for setting an IP0 digit for example Reviewing and Setting the General Network Socket Port Reviewing and Setting the General Network Socket PortReviewing and Setting the General Network IP Address Reviewing and Setting the General Network IP AddressReviewing and Setting the Subnet Mask and Default Gateway Reviewing and Setting the Subnet Mask and Default Gateway Appears in the secondary displayViewing the Device Ethernet Address Viewing the Device Ethernet AddressExamples for Viewing the Ethernet Address Installing Host Computer Ethernet Adapter Host Computer and Network PreparationSoftware Preparing for Network OperationDevice and Host Computer Interconnection Host Computer/Device Direct ConnectionInterconnection Using 10/100BaseT Twisted Pair Wiring Installing Host Computer Networking Software Setting Host Computer Networking Parameters Installing Fluke DAQ Software To install Fluke DAQ software on your computerInstalling Fluke DAQ Software Fluke DAQ Toolbar Buttons Function Using the ToolbarUnderstanding the User Interface Understanding the User Interface Understanding the Workspace Area Module Status Icon Checking Operational StatusDevice Status Icon Computed Channel Status IconDevice Configuration Dialog Configuration DialogsNetwork Configuration Dialog DIO Configuration Dialog Module Configuration DialogAnalog Channel Configuration Dialog Computed Channel Configuration DialogCommunication Dialogs Security DialogsTrend Dialog Alarm DialogMail and Web Settings Dialogs To insert and configure a device Managing Your Network Using Fluke DAQInserting and Configuring a 268XA Device Advanced Setting autodisable scan Interval 3 autoscan rate Configuration fileGroup is externally wired Network TypeTreeView panel, select the device you just added IP Address Configuration transferTemperature Units Verify ButtonScan Overflow Monitor ChannelScan Parameters Log to PC Card 2686A onlyModule Number Inserting and Configuring a ModuleTo insert and configure a module Module TypeAlg109s.bmp External Trigger Alarm TriggerInterval Trigger Drift CorrectionDirection Start CountDebounce Inserting and Configuring a Channel To insert and configure a ChannelLabel Alarm TypeCH # Unit LabelConfiguring a Computed Channel Alg117s.bmp Computed channels are assigned channel numbers from 901 to Trigger Scan With Module Use Channel as Alarm TriggerDigital Output Channel a or Channel BUsing Equations with Computed Channels Alg120s.bmp Starting a Scan Starting a Configuration ScanTo start a configuration scan Starting a Device Scan To start a device scanStarting a Scan Using Spy To start a Spy scanViewing Module Measurement Data To view module measurement dataUsing the Digital I/O Points Communication Dialog To view digital I/O points dialogUsing Trend to View Collected Data To use the trend featureZoom PenType ExportStart Date/Start Time Device IDModule DurationChanging the Chart Display To change the strip chart displayViewing Alarms To view alarmsPeriod of Viewing Alarm Device FiltersAck Using Fluke DAQ System Security Features To use the system security featureConfiguring Web and Alarm Mail Settings To enter web and alarm mail settingsData Server IP Address Send alarms by e-mailUpdate Uniform Resource Locator URL

2686A, 2680A specifications

The Fluke 2680A and 2686A are sophisticated data acquisition systems designed for versatile applications in electrical and environmental testing. These high-performance devices cater to engineers and technicians who require reliable and precise measurement capabilities.

At the heart of these instruments is their advanced modular design, which allows users to customize the system according to specific measurement needs. The Fluke 2680A offers eight channels, while the 2686A boasts an impressive 20 channels of data acquisition, thus providing flexibility for various testing scenarios. This modularity ensures that users can easily expand their measurement capabilities by adding more channels or switching between different measurement modules.

One of the standout features of the Fluke 2680A and 2686A is their ability to perform simultaneous measurements across multiple channels. This is particularly beneficial for applications that require real-time data analysis, minimizing the time spent on sequential measurements. With sample rates reaching up to 100 kS/s, these devices provide quick and accurate data collection, making them ideal for both laboratory settings and field use.

Both models incorporate advanced signal conditioning technology, enabling them to handle a wide range of input types, including voltage, current, temperature, and resistance. This capability eliminates the need for external signal conditioning equipment, streamlining the setup and reducing overall costs for users. The inclusion of built-in digital filtering and scaling further enhances measurement accuracy, ensuring reliable results even in noisy environments.

The Fluke 2680A and 2686A also feature robust connectivity options, including USB, Ethernet, and RS-232 interfaces. This promotes seamless integration into existing networks and facilitates remote monitoring and control. Additionally, both devices support various programming languages, allowing for easy automation of testing procedures.

Another highlight is the intuitive user interface that allows users to configure the device with minimal effort. An embedded web server provides remote access to the instrument, enabling users to monitor data and configure settings from anywhere.

In summary, the Fluke 2680A and 2686A stand out as premier data acquisition systems, offering exceptional modularity, versatile measurement capabilities, and advanced connectivity options. Their combination of speed, accuracy, and ease of use makes them indispensable tools for professionals in testing and measurement applications.