Fluke 2686A IP Address, Verify Button, Configuration transfer, Description, Temperature Units

Page 47

Getting Started

Managing Your Network Using Fluke DAQ

6.Set the IP Address on the Device Settings dialog. Other fields are optional. You may need to contact your Internet support staff to determine the IP Address.

alg106s.bmp

The dialog box entries include:

IP Address

Enter the IP Address of the device you are adding.

Verify Button

Click the Verify button to ping the device and verify that the IP Address is correct. The device and your PC must both be connected to the network for this to work.

Configuration transfer

You can transfer configuration information from the PC to the device, from the device to the PC, or from a PC Card to a PC or the device. PC Card operations are available only for the 2686A.

Description

Enter a meaningful description of the device. 35 characters maximum.

Temperature Units

Specify Celsius or Fahrenheit. This will automatically select temperature units for all temperature measurements.

37

Image 47
Contents 2680A/2686A Limited Warranty and Limitation of Liability Interference Information Safety InformationSafety Terms in this Manual Xwwarning Xwwarning Do not Operate in Explosive Atmospheres General Specifications Characteristic Additional Safety InformationSpecification Page Table of Contents 2680A/2686A Introduction Getting StartedAdditional Information Contacting FlukeReviewing and Setting the Base Channel Number Configuring the 268XAReviewing and Setting the Base Channel Number Examples for Reviewing and Setting the BCN Reviewing and Setting the Line Frequency Reviewing and Setting the Line FrequencyExamples for Reviewing and Setting the Line Frequency Reviewing and Setting the Network Type Reviewing and Setting the Network TypeExamples for Reviewing and Setting the Network Type Reviewing and Setting the Network Type to General Communications display for reviewing the network type IP address display for setting an IP0 digit for example Reviewing and Setting the General Network Socket Port Reviewing and Setting the General Network Socket PortReviewing and Setting the General Network IP Address Reviewing and Setting the General Network IP AddressReviewing and Setting the Subnet Mask and Default Gateway Appears in the secondary display Reviewing and Setting the Subnet Mask and Default GatewayViewing the Device Ethernet Address Viewing the Device Ethernet AddressExamples for Viewing the Ethernet Address Host Computer and Network Preparation Installing Host Computer Ethernet AdapterPreparing for Network Operation SoftwareHost Computer/Device Direct Connection Device and Host Computer InterconnectionInterconnection Using 10/100BaseT Twisted Pair Wiring Installing Host Computer Networking Software Setting Host Computer Networking Parameters To install Fluke DAQ software on your computer Installing Fluke DAQ SoftwareInstalling Fluke DAQ Software Fluke DAQ Toolbar Buttons Function Using the ToolbarUnderstanding the User Interface Understanding the User Interface Understanding the Workspace Area Computed Channel Status Icon Checking Operational StatusDevice Status Icon Module Status IconDevice Configuration Dialog Configuration DialogsNetwork Configuration Dialog Computed Channel Configuration Dialog Module Configuration DialogAnalog Channel Configuration Dialog DIO Configuration DialogSecurity Dialogs Communication DialogsTrend Dialog Alarm DialogMail and Web Settings Dialogs To insert and configure a device Managing Your Network Using Fluke DAQ Inserting and Configuring a 268XA Device Network Type Configuration fileGroup is externally wired Advanced Setting autodisable scan Interval 3 autoscan rateTreeView panel, select the device you just added Verify Button Configuration transferTemperature Units IP AddressLog to PC Card 2686A only Monitor ChannelScan Parameters Scan OverflowModule Type Inserting and Configuring a ModuleTo insert and configure a module Module NumberAlg109s.bmp Drift Correction Alarm TriggerInterval Trigger External TriggerDirection Start CountDebounce To insert and configure a Channel Inserting and Configuring a ChannelUnit Label Alarm TypeCH # LabelConfiguring a Computed Channel Alg117s.bmp Computed channels are assigned channel numbers from 901 to Channel a or Channel B Use Channel as Alarm TriggerDigital Output Trigger Scan With ModuleUsing Equations with Computed Channels Alg120s.bmp Starting a Scan Starting a Configuration ScanTo start a configuration scan To start a device scan Starting a Device ScanTo start a Spy scan Starting a Scan Using SpyTo view module measurement data Viewing Module Measurement DataTo view digital I/O points dialog Using the Digital I/O Points Communication DialogTo use the trend feature Using Trend to View Collected DataExport PenType ZoomDuration Device IDModule Start Date/Start TimeTo change the strip chart display Changing the Chart DisplayTo view alarms Viewing AlarmsPeriod of Viewing Alarm Device FiltersAck To use the system security feature Using Fluke DAQ System Security FeaturesTo enter web and alarm mail settings Configuring Web and Alarm Mail SettingsUniform Resource Locator URL Send alarms by e-mailUpdate Data Server IP Address