5 Specifications

5 Specifications

This chapter contains the environmental and mechanical specifications for the AMC-S402. The environmental specifications relate to and vary with the Hard Drive that the AMC-S402 is configured with.

5.1Physical Characteristics

The AMC-S402 module board is 7.11 inches x 2.89 inches. The cards component height conformance is a function of the disk drive selected. Order options exist for mid or full height panels. (See section 1.3 Products Supported by this Manual).

5.1.1AMC Module Height Exceptions

This module slightly exceeds the height profile dimensions listed in the AMC.0 specification. These exceptions are detailed below.

 

Table 7 AMC-S402 Module Height Details, No Heat Sink

 

 

 

item

Description

Dimension Delta

1

Maximum height, Envelope 2, Component side

+0.13mm exception (nominal), +0.33mm worst case

 

 

 

2

Maximum height, underside

+0.28mm exception (nominal), +1.0mm worst case

 

 

 

6806800H60A AMC-S402 Installation and Use

15

Image 25
Contents AMC-S402 Installation and Use6806800H60A March Trademarks 2009 Emerson All rights reservedLimited and Restricted Rights Legend Contact Address2.2.1 Contents2.3.1 2.4.1SPECIFICATIONS 7.2.1FRONT PANEL INDICATORS IPMI FIRMWARE UPGRADE PROCEDUREList of Tables List of FiguresPreface Safety SummaryFlammability Safety StatementEMI Caution CE Notice European CommunityAbout This Manual commands, options and arguments to commands, andHow This Manual is Organized Conventions Used in This Manualcourier introduce new termsSystem output for example, screen displays and reports examples, and system promptsAntistatic Precautions Hardware Preparation and InstallationUnpacking Instructions 1.2 PICMG Standards Compliance 1.1 Features of the AMC Module1.3 Products Supported by this Manual 1 AMC-S402 OverviewAMC-S402 Overview 1.4 Part Number, Serial Number LabelsSub-Assembly Number Final Assembly Number5 Safety Label Serial Number2.1 Installation and Removal of the AMC-S402 Module 2 AMC-S402 Installation2.2.1 Safety Statement 2.3 Before You Install or Remove the AMC2.3.2 Watch for Bent Pins or Other Damage 2.3.1 Observe ESD Precautions2.4 Use Caution When Installing or Removing AMC AMC-S402 Installation2.5 Verify Slot Usage 2.4.2 Understand Hot Swap2.6 Module Hot-Swap 2.7 Installing the AMC Module 2.8 Removing the AMC Module 3.1 Overview 3 Functional Description3.2 AMC-S402, Top Level Board Layout Power Regulator MMC3.3.1 SAS Port Isolation Multiplexor Circuit 3.3 Serial Storage I/O InterfacesFunctional Description 3.5 IPMI Subsystem 3.4 Power Regulator4.2 AMC Connector, “Finger” Assignments 4 Connector Pin Assignments4.1 AMC-S402 Port Assignments AMC.3 Serial Storage Port AMC.3 Serial Storage PortTable 6 AMC-S402 Module Edge, Pin Assignments Connector Pin AssignmentsSignal Name 5.1 Physical Characteristics 5 Specifications5.1.1 AMC Module Height Exceptions Specifications 5.2 Hard Drive Operation and Storage Specifications5.4 EMC Compliance 5.3 Power RequirementsPart number AMC-S402xxxEurope Commercial EN 61000-4-4 Table 10 EMC Emission CompliancyYes, Class A ITE emissions requirements Australia Indicator 6 Front Panel IndicatorsColor State7.1 IPMI and Management Controller IPMC 7 IPMI Functions List7.2 Sensor Data Records IPMI Functions List 7.2.1 AMC Port AssignmentsIPMI Function List 7.3 Supported IPMI CommandsIPMI Function List 8.1 The ipmitool utility 8 IPMI Firmware Upgrade ProcedureSYNOPSIS DESCRIPTIONIPMI Firmware Upgrade Procedure COMMAND SYNTAX EXAMPLES