5.3Power Requirements

Specifications

5.3Power Requirements

The AMC-S402 shall consume no more than the following from the system supplies under normal operating conditions.

Table 9 Power Requirements

Part number

AMC-S402xxx

 

 

Management Power

100mA

(MP)

 

 

 

 

 

+12V (spin up < 100

1.5A

(18W)

sec)

 

 

+12v normal operating

0.9A

(10.8W)

 

 

 

+12v (idle)

0.5A

(6W)

 

 

OFF STATE

LESS THAN 0.4W

 

 

 

5.4EMC Compliance

This product was tested in an EMC-compliant chassis and meets the requirements for EN55022 Class A equipment. Compliance was achieved under the following conditions:

Conductive chassis rails connected to earth ground, providing the path for connecting shields to earth ground

Front panel screws properly tightened

For minimum RF emissions, it is essential that the conditions above be implemented. Failure to do so could compromise the EMC compliance of the equipment containing the module.

6806800H60A AMC-S402 Installation and Use

17

Image 27
Contents Installation and Use AMC-S4026806800H60A March Contact Address 2009 Emerson All rights reservedTrademarks Limited and Restricted Rights Legend2.4.1 Contents2.2.1 2.3.1IPMI FIRMWARE UPGRADE PROCEDURE 7.2.1SPECIFICATIONS FRONT PANEL INDICATORSList of Tables List of FiguresPreface Safety SummaryCE Notice European Community Safety StatementFlammability EMI CautionConventions Used in This Manual commands, options and arguments to commands, andAbout This Manual How This Manual is Organizedexamples, and system prompts introduce new termscourier System output for example, screen displays and reportsHardware Preparation and Installation Antistatic PrecautionsUnpacking Instructions 1 AMC-S402 Overview 1.1 Features of the AMC Module1.2 PICMG Standards Compliance 1.3 Products Supported by this ManualAMC-S402 Overview 1.4 Part Number, Serial Number LabelsSerial Number Final Assembly NumberSub-Assembly Number 5 Safety Label2.3 Before You Install or Remove the AMC 2 AMC-S402 Installation2.1 Installation and Removal of the AMC-S402 Module 2.2.1 Safety StatementAMC-S402 Installation 2.3.1 Observe ESD Precautions2.3.2 Watch for Bent Pins or Other Damage 2.4 Use Caution When Installing or Removing AMC2.4.2 Understand Hot Swap 2.5 Verify Slot Usage2.6 Module Hot-Swap 2.7 Installing the AMC Module 2.8 Removing the AMC Module Power Regulator MMC 3 Functional Description3.1 Overview 3.2 AMC-S402, Top Level Board Layout3.3 Serial Storage I/O Interfaces 3.3.1 SAS Port Isolation Multiplexor CircuitFunctional Description 3.5 IPMI Subsystem 3.4 Power RegulatorAMC.3 Serial Storage Port AMC.3 Serial Storage Port 4 Connector Pin Assignments4.2 AMC Connector, “Finger” Assignments 4.1 AMC-S402 Port AssignmentsTable 6 AMC-S402 Module Edge, Pin Assignments Connector Pin AssignmentsPin# 5 Specifications 5.1 Physical Characteristics5.1.1 AMC Module Height Exceptions Specifications 5.2 Hard Drive Operation and Storage SpecificationsAMC-S402xxx 5.3 Power Requirements5.4 EMC Compliance Part numberTable 10 EMC Emission Compliancy Europe Commercial EN 61000-4-4Yes, Class A ITE emissions requirements Australia State 6 Front Panel IndicatorsIndicator Color7 IPMI Functions List 7.1 IPMI and Management Controller IPMC7.2 Sensor Data Records IPMI Functions List 7.2.1 AMC Port AssignmentsIPMI Function List 7.3 Supported IPMI CommandsAMC Spec DESCRIPTION 8 IPMI Firmware Upgrade Procedure8.1 The ipmitool utility SYNOPSISIPMI Firmware Upgrade Procedure COMMAND SYNTAX EXAMPLES