Emerson AMC-S402 IPMI Functions List, IPMI and Management Controller IPMC, Sensor Data Records

Page 30
7 IPMI Functions List

7 IPMI Functions List

The AMC-S402 module employs a Module Management Controller (MMC) as specified in the AMC.0 specification. The MMC provides an Intelligent Platform Management Interface (IPMI) which will communicate with the ATCA and MicroTCA shelf managers. This MMC controls and monitors the following:

Hot swap communication with the shelf manager

Inlet air temperature

Voltage monitoring

Electronic keying as described in the AMC.0 specification

FRU information

Drives LED indicators for Hot Swap, In Service, and Out of Service

7.1IPMI and Management Controller (IPMC)

The design features an IPMI controller consisting of a 16-bit microcontroller, flash and SRAM. The microcontroller uses I2C interface to communicate the shelf management controller (ShMC), and sensors and MMC devices on AMC modules.

An I2C connection provides the communication path between the MMC the temperature sensor. The I2C serial bus also routes to the SFP+ modules.

Support hot-swap operation as defined for AMC modules in PICMG AMC.0 specification “Fail-safe flash update” - if interrupted at anytime, the MMC firmware is still able to respond and re-flash.

“I2C hang recovery” - able to detect and recover from an I2C bus hang.

7.2Sensor Data Records

The MMC monitors the status of the module and provides this data so the shelf manager can read it. Below are the SDRs that the AMC-S402 module creates.

Table 12 Sensor Data Records

Sensor

UNR

UC

UNC

LNC

LC

LNR

ID String

1.8V

1.98

1.93

1.90

1.70

1.67

1.62

+1.8V

 

 

 

 

 

 

 

 

5.0V

5.50

5.35

5.25

4.75

4.65

4.5

+5V

 

 

 

 

 

 

 

 

12V

13.60

13.40

13.00

11.00

10.60

10.400

+12V

 

 

 

 

 

 

 

 

Board Temp (LM60)

80

70

60

N/A

N/A

N/A

Board Temp

 

 

 

 

 

 

 

 

Inlet Temp (LM75)

70

60

50

N/A

N/A

N/A

Inlet Temp

 

 

 

 

 

 

 

 

The AMC-S402 includes the standard FRU data records per the IPMI Platform Management FRU Information Storage Definition, Board Info Area. The AMC-S402 includes additional FRU records as defined in the PICMG 2.9 specification.

6806800H60A AMC-S402 Installation and Use

20

Image 30
Contents Installation and Use AMC-S4026806800H60A March Limited and Restricted Rights Legend 2009 Emerson All rights reservedTrademarks Contact Address2.3.1 Contents2.2.1 2.4.1FRONT PANEL INDICATORS 7.2.1SPECIFICATIONS IPMI FIRMWARE UPGRADE PROCEDUREList of Figures List of TablesSafety Summary PrefaceEMI Caution Safety StatementFlammability CE Notice European CommunityHow This Manual is Organized commands, options and arguments to commands, andAbout This Manual Conventions Used in This ManualSystem output for example, screen displays and reports introduce new termscourier examples, and system promptsHardware Preparation and Installation Antistatic PrecautionsUnpacking Instructions 1.3 Products Supported by this Manual 1.1 Features of the AMC Module1.2 PICMG Standards Compliance 1 AMC-S402 Overview1.4 Part Number, Serial Number Labels AMC-S402 Overview5 Safety Label Final Assembly NumberSub-Assembly Number Serial Number2.2.1 Safety Statement 2 AMC-S402 Installation2.1 Installation and Removal of the AMC-S402 Module 2.3 Before You Install or Remove the AMC2.4 Use Caution When Installing or Removing AMC 2.3.1 Observe ESD Precautions2.3.2 Watch for Bent Pins or Other Damage AMC-S402 Installation2.4.2 Understand Hot Swap 2.5 Verify Slot Usage2.6 Module Hot-Swap 2.7 Installing the AMC Module 2.8 Removing the AMC Module 3.2 AMC-S402, Top Level Board Layout 3 Functional Description3.1 Overview Power Regulator MMC3.3 Serial Storage I/O Interfaces 3.3.1 SAS Port Isolation Multiplexor CircuitFunctional Description 3.4 Power Regulator 3.5 IPMI Subsystem4.1 AMC-S402 Port Assignments 4 Connector Pin Assignments4.2 AMC Connector, “Finger” Assignments AMC.3 Serial Storage Port AMC.3 Serial Storage PortConnector Pin Assignments Table 6 AMC-S402 Module Edge, Pin AssignmentsSignal Name 5 Specifications 5.1 Physical Characteristics5.1.1 AMC Module Height Exceptions 5.2 Hard Drive Operation and Storage Specifications SpecificationsPart number 5.3 Power Requirements5.4 EMC Compliance AMC-S402xxxTable 10 EMC Emission Compliancy Europe Commercial EN 61000-4-4Yes, Class A ITE emissions requirements Australia Color 6 Front Panel IndicatorsIndicator State7 IPMI Functions List 7.1 IPMI and Management Controller IPMC7.2 Sensor Data Records 7.2.1 AMC Port Assignments IPMI Functions List7.3 Supported IPMI Commands IPMI Function ListIPMI/PICMG SYNOPSIS 8 IPMI Firmware Upgrade Procedure8.1 The ipmitool utility DESCRIPTIONIPMI Firmware Upgrade Procedure COMMAND SYNTAX EXAMPLES