Emerson Series 600, SERIES 600T Control Panel, Control panel keyboard layout refer to Figure

Page 65

Operation

6.2Control Panel

The Control Panel (see Figure 54) below represents the Control Panel on the Liebert FS. The dia- gram is labeled as a reference for the various keys, functions and data found on the Control Panel.

NOTE

(The actual locations of status indicators on the Control Panel display, corresponding to the numbers below, may vary from Figure 54 depending on software version.)

Figure 54 Control panel view

See Table 4

for keyboard layout

 

 

 

 

 

8

9

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

 

 

LIEBERT FS

 

 

D V U C P

 

 

 

 

 

RPM:

50652

12

 

7

 

 

 

 

 

MODE:

DISCHARGE

 

SOC:

93.3%

 

 

SOC:

6

STATUS:

OK

 

 

BUS:

500 V

13

 

 

 

PWR:

190 .2kW

 

 

 

 

 

 

 

 

 

MENU

SHUTDN

 

LOCK

 

 

 

5

 

 

 

 

 

 

 

14

4

 

F1

F2

F3

F4

F5

F6

15

3

 

I

!

 

 

 

 

16

2

 

0

1

2

3

 

 

17

 

 

 

18

 

 

 

 

 

 

 

 

1

.

4

5

6

X

19

 

 

 

 

 

 

-

7

8

9

 

NOTE

The control panel view is for reference only. Not all items will be enabled and visible on the screen at the same time during operation

Navigating the control panel is a simple process that involves responses to user prompts displayed in the control panel. Using the panel to operate the unit will be described further in this section.

Table 4

Control panel keyboard layout (refer to Figure 54)

 

 

 

 

Keyboard

 

Keyboard

 

Location

Operation / Navigation Keys

Location

Screen Indication Keys

1

Numerical Keypad

11

SOC: State of Charge Bar

 

 

 

 

2

LEDs used for Servicing

12

SOC: State of Charge Value

 

 

 

 

3

F2 Shutdown key - Main Screen

13

PWR: Bus Power

 

 

 

 

4

F1 Start Up key - Main Screen

14

F5 More Information key - Fault Screen

 

 

 

 

5

Soft Menus

15

F6 Menu key - Main Screen

 

 

 

 

6

STATUS: System status (see 6.2.3 -

16

F3 Clear Fault key - Fault Screen

System STATUS Indicators)

 

 

 

7

MODE: System mode (see 6.2.2 -

17

Enter key

System MODE Indicators)

 

 

 

8

BUS: Internal DC Bus Voltage

18

Scroll Up and Down keys

 

 

 

 

9

RPM: Flywheel Rotation Speed

19

Backspace

 

 

 

 

10

Power and Options: On/Off

 

 

 

 

 

 

53

Image 65
Contents Liebert FS DC Energy Storage System Page Table of Contents Operation System OverviewTroubleshooting MaintenanceAppendix B.0 Data Collection Module Appendix A.0 UPS Interconnection KitsAppendix E.0 Specifications Appendix D.0 Installation DrawingsAppendix F.0 Auxiliary Backup AC Power Supply Appendix C.0 Versatile Interface BoardFigures Vii Versatile Interface Board mounted in the Liebert FS 110 Tables Page Important Safety Instructions Safety Precautions General Information Safety ConsiderationsRequesting Assistance from Liebert System informationLiebert FS General System DescriptionDC Bus Loads Utility PowerLiebert FS Unit Liebert FS Unit 1 Liebert FS UnitGeneral Specifications Battery NGeneral system specifications LiebertKey Technological Features Features and BenefitsKey Customer Benefits Applicable Standards and CertificationKW-sec delivered GT model, 510 VDC, with filter Rectifier Utility Static SwitchBypass Environmental Considerations System LocationElectrical Considerations Flooring RequirementsStatus/Control Connections AC Power ConnectionsGrounding Connections Remote Monitoring Connections-Optional14623 Inspection Before Removal From the TruckUnloading Unpacking HandlingRemoving the metal support plates Lifting the Liebert FS cabinetPositioning the Liebert FS Storing the Liebert FS for Delayed InstallationMoving the Liebert FS Manuals Serial Number Model Number PlatesFront Right Side 12-100120-09 TopBottom Front Right Side Door open Panel removed Internal layoutFloor Mounting Bracket Cabinet Floor MountingFront of Liebert FS Mounting ToolsConcrete, Masonry or Stone Floor Mounting Instructions Checking hole depth 12.7mm Floor to Flange Bolt securing bracket to cabinetBubble level Mounting front bolts-front side of cabinetWood Floor Mounting Parts Wood Floor MountingWood Floor Mounting Tools Wood Floor Mounting InstructionsRaised Floor Mounting Instructions Raised Floor Mounting Raised Floor Mounting KitRaised Floor Mounting Tools General Wiring Considerations Wiring ConnectionsFront RearCircuit Breaker Mounting Plate Control DC and Ground Connections Communication Access PanelGround Connections Ground Wire Gauge Tightening Torque Approximate metric InchTightening torque for ground connection PoundsService panel location AC Auxiliary Control Power Supply ConnectionsTerminal Neutral Line Ground Fused disconnectRemote monitoring DCM connections inside cabinet front door Startup ConsiderationsLiebert FS front view Detailed System DescriptionSystem Module Description Power Conversion ModuleControl Panel UPS Interconnection KitElectrical system schematic Flywheel Module Power SystemBattery Input System PerformanceVersatile Interface Board VIB User interfaces Control PanelData Collection Module DCM Igbt Power Conversion Module PCM Active Magnetic Levitation Hardware Magnetic Levitation Module MLMUpper Radial Axial ElectromagnetMotor Generator Rotor/Flywheel-Rotating GroupVacuum system operation Vacuum SystemFlywheel Sensors Speed TemperatureCabinet System SafetyOuter Housing Rotating Group Inner Housing Coolant List of System User-Configurable Parameters Max Charge Current Voltage Behavior Current Sink Regulation Voltage Delta During Discharge Vreg DeltaVreg delta help screen Modes of OperationStandby Mode OFF ModeStartup Mode UPS DC Bus Voltage = VchargeVoltage ≥ Vcharge Charge ModeReady Mode Following a Liebert FS Discharge Down to SOC = 0% Discharge ModeShutdown Mode Fault Mode Following a User CommandCoast Mode Typical operation modes KEY # Mode DescriptionMaintenance and Reliability Operator Controls Access System HistorySystem Mode Indicators System Status IndicatorsControl Panel Control panel keyboard layout refer to FigureMain screen function descriptions System Status Indicators System Mode IndicatorsSystem status indicators Operation modesUninstalled DisabledOther Status Indicators OperativeMenu Tree and Navigation Security AccessMenu tree Navigation and Operation of Control Panel System Setup and Parameter Access2VREG Time/Date ViewHistory TemperaturesVoltages 01 03/10/05 1143 W 12302 03/10/05 1037 W 03 02/24/05 0403 WOptions 192.168.1.155 Network-Requires DCM Option255.255.255.0 192.168.1.1Security ElectricalVitals Change password Password screensTools AboutCopyright Appl PRI-3.00 SEC-3.01 BL PRI-3.02 SEC-3.01 001 FM S/N MLM S/N 0001 PCM S/N 0002 SO# 123-456-7Inspection before Initial System Startup Initial System Startup ProcedureSystem Startup Control Parameter Value Default Control Parameters Setup at Initial System StartupControl parameters Software versionsPowering Up the Liebert FS Regular Startup ProcedureBooting Up Inspection Before Regular StartupValidation of Control Parameters Setup Shutdown ProcedureInitiating Liebert FS Startup Sequence Liebert FS Startup SequenceSafety Precautions Routine Maintenance Liebert Global ServicesMaintenance schedule Maintenance ScheduleRecord Log FrequencyOptional Air Filters Torque specifications unless otherwise labeledTorque Requirements Detecting TroubleCorrective Actions Reporting a ProblemRecommended Test Equipment Limited Life ComponentsUser level menu GeneralButton F5 ChargeAuxpower Meaning / Possible Causes Troubleshooting LabelMore information Fault Clear Button F3 Button F5 FaultsBus Power BUS Current Offset Faults-causes and responsesTroubleshooting Fault Label Troubleshooting Action Appendix A.1.1 General Wiring Considerations Appendix A.1 Wiring ConnectionsKey to UPS model interconnection Liebert FS Model # Use With Liebert UPSTop view of Liebert FS Cabinet with UPS interconnection kit Front RearLiebert FS Positive Terminal Negative Appendix A.1.2 DC Power ConnectionsCircuit Breaker Torque UPS Output Rating KVA Liebert Series 610/600T/600 model ratingsYellow Blue Two rows Row for Liebert FS Software Control Parameter Setting Liebert FS Software Control Parameter settingsLiebert FS Npower UPS Liebert Npower model ratingsOutput RatingSee Table Liebert FS Software Setting Control ParameterLiebert FS Software Control Parameters UPS Interconnection Kits Liebert Series 300 UPS List of Liebert Series 300 models ratingsLiebert Series 300 status/control terminal block wiring 395VDC Liebert HiPulse model ratings Appendix A.5.1 Description-HiPulse UPS Interconnection KitLiebert FS positive terminal Liebert FS negative terminal Appendix A.5.3 IKIT-A05 DC Power ConnectionsUPS Output Rating kVA 120 Appendix A.5.5 Single Liebert FS on UPS DC BusMultiple Liebert FS Parallel Operation-Regular Configuration Appendix B.1.2 Features Appendix B.2 DCM Installation and ConfigurationAppendix B.2.1 Installation Appendix B.1 General InformationAppendix B.2.2 DCM Requirements LAN Connection Power Connection255.255.255.0 192.168.1.155192.168.1.1 192.168.1.13Enter IP Address Appendix B.2.3 Accessing the DCMAppendix B.2.4 Configuring DCM System Parameters Appendix B.3.2 Status and Detailed Status Screens Appendix B.3 DCM OperationAppendix B.3.1 Logging into the DCM Datafiles screen Appendix B.3.3 Datafiles ScreenAppendix B.4.1 DCM Troubleshooting Principles Appendix B.4 DCM TroubleshootingAppendix B.4.2 Resetting the DCM TroubleshootingAppendix C.1.1 Versatile Interface Board Overview Appendix C.1 General Information-Versatile Interface BoardVIB I/O functions Interface VIB Designation Description Appendix C.1.2 VIB FeaturesO Designations Label X20Appendix C.2.1 VIB Installation Appendix C.2 VIB Installation and ConfigurationAppendix C.2.3 VIB Input Specifications Appendix C.2.4 VIB Output SpecificationsAppendix C.3 VIB Operation Appendix C.4.2 VIB in Disabled or Not Available State Appendix C.4 Troubleshooting the VIBAppendix C.4.1 UIB State Not Displayed on the Front Panel Appendix C.4.3 Inputs Not RecognizedSubmittal documents accompanying Liebert FS Storage Solution Flywheel Storage SolutionAppendix D.1 Liebert FS Flywheel Submittal Document Matrix Appendix D.2 Other Liebert FS Drawings No UVR, circuit breaker to terminal block wiringElectrical connections Electrical system block diagram 48 UVR, circuit breaker to terminal block wiring 24 UVR, circuit breaker to terminal block wiringOutline drawing, Liebert FS cabinet Fused Disconnect Liebert FS FS cabinet to Liebert Series 610 UPS module Control wiring-external interconnect diagram, LiebertElevation drawing, Liebert FS cabinet with shipping package Front Elevation drawing-Liebert FS cabinet124 Liebert FS cabinet with optional power terminal block Mechanical Cabinet127 Liebert FS Systems Parallel + GND Systems 138One-line moduleWith factory CircuitLiebert UPS Module 401 Parallel with a LiebertUPSUnits Liebert UPS Module Liebert UPS Module Status/control Wiring, multiple unitsWiring specifications, Liebert FS and Liebert Series Wiring specifications, Liebert FS and Liebert Npower Wiring specifications, Liebert FS and Liebert Series Wiring specifications, Liebert FS and Liebert HiPulse 29-1/2 749mm Drill Template Dwg Cabinet Come with Liebert FS block diagram Power line diagram UPS cable entry-bottom Liebert FS Cabinet Phase Unit N Input Bus + Bus Ground BusUPS cable entry-top Liebert FS Cabinet Phase Unit N InputTOP View Technical specifications Appendix E.0 SpecificationsItems Required Appendix E.1 Ground Test ProcedureAppendix F.3 Recommended Backup Power Supply Configuration Appendix F.2 Backup AC Power Supply SpecificationAppendix F.1 Overview Frequency 50 to 60HzGrid supply DC bus Battery Liebert FS PackGrid Appendix F.3.2 Operating the Liebert FS Without BatteriesSupply Output DistributionLiebert FS Flywheel module Appendix F.4 ScenariosAuxiliary Backup AC Power Supply 154 Page Iti Ne tTi n That
Related manuals
Manual 84 pages 14.4 Kb

Series 600, SERIES 600T specifications

The Emerson SERIES 600T, as part of the SERIES 600 line, is a sophisticated device designed to meet the demands of industrial automation and control systems. Renowned for its reliability and versatility, the SERIES 600T excels in various applications across multiple sectors, including oil and gas, chemical processing, and power generation.

One of the most significant features of the SERIES 600T is its advanced measuring capability. It offers exceptional accuracy, typically within ±0.1% of the full scale. This precision makes it suitable for critical applications where measurement integrity is paramount. The SERIES 600T is also equipped with intelligent diagnostics that can predict and monitor the health of the unit, enabling proactive maintenance and minimizing downtime. This technological advancement improves both operational efficiency and safety.

Another standout characteristic is the device's robust construction designed to withstand harsh environments. The SERIES 600T is made with durable materials that provide resistance to corrosion, vibration, and temperature extremes, making it an excellent choice for rugged industrial applications. Coupled with its IP67 rating, the device is fully sealed against dust and moisture, ensuring long-term reliability in challenging conditions.

The SERIES 600 line employs cutting-edge communication protocols, including HART and Foundation Fieldbus, facilitating seamless integration into various control systems. This capability ensures that users can easily access real-time data and manage devices remotely, significantly enhancing operational efficiency.

Additionally, the SERIES 600T supports a wide range of process connections and configurations, catering to diverse installation needs. This adaptability allows for quick deployments and minimizes the time required for system changes or upgrades.

With easy-to-read displays and user-friendly interfaces, operators can quickly interpret data and metrics from the SERIES 600T. This intuitive design helps reduce the learning curve for new users, further underlining the device's legacy of reliability and efficiency.

In essence, the Emerson SERIES 600T exemplifies cutting-edge technology in the realm of industrial measurement and automation. Its combination of accuracy, durability, diagnostic capabilities, and ease of integration makes it an ideal choice for industries that prioritize reliability and precision in their operations. As industrial processes continue to evolve, devices like the SERIES 600T will undoubtedly play a crucial role in advancing efficiency and productivity in various sectors.