Jenn-Air 1300, 1892 manual Channel Step Size AT S161, Test Message Period AT S162

Page 20

The power is set with the command:

 

AT S160=n<CR><LF>

Where:

sets the power threshold <1 to 10>

Default:

10

Read

AT S160?<CR><LF>

Read Return:

nn<CR><LF>

Example:

AT S160=-10<CR><LF> sets the power level to 10

4.15Channel Step Size (AT S161)

This command sets the channel step size. The basic reference frequency for the radio is either 12.5KHz or 10KHz, giving possible frequency channel steps of 10kHz, 12.5kHz, 20kHz and 25kHz. The Channel Step Size is set with the command:

 

AT S161=n<CR><LF>

Where:

n=1 10 kHz

 

n=2 12.5 kHz

 

n=3 20 kHz

 

n=4 25 kHz

Default:

n=2 (12.5 kHz)

Read:

AT S161?<CR><LF>

Read Return:

n<CR><LF>

Example:

AT S161=1<CR><LF> sets 10 kHz channel step

If a channel step size is entered which is not a multiple of the centre frequency an error is returned and the entry ignored. This is to ensure that only valid frequencies on multiples of the channel step size are allowed based on the centre frequency entered. The error message is of the form:

ERROR<CR><LF>

4.16Test Message Period (AT S162)

This command sets the period between sending the test message. The command is:

 

AT S162=n<CR><LF>

 

Where:

n=1 - 255 in 10ms steps

 

Default:

n=10 (100ms)

 

Read:

AT S162?<CR><LF>

 

Read Return:

nnn<CR><LF>

 

Example:

AT S162=100<CR><LF>

sets 1 second period

Hermes Operator Note

Page 20 of 32

Image 20
Contents Tel +44 0 118 981 Fax +44 0 118 981 Specialist RF DesignsLattice House Baughurst Basingstoke UK RG26 5LP Handshaking Operation During Transmit and Receive Table Of ContentsReceived Signal Strength Indication Rssi AT S156 List of Figures List of TablesIntroduction Pin No Function RS232 ConnectorConnections & Indications Front Panel Indications Power ConnectorRF Connector Modem Operation IntroductionReceive-to-Transmit Turnround Data Transfer ModesRS232 Data Handling MAX Time msDescription Okcrlf List of CommandsCommand Mode Command Syntax ErrorcrlfBaud Rate AT B0 Parity ATB1Format Mode AT F AT F?CRLFRXX, Dxxxcrlf Engineering Test Modes ATOK Crlf Command Mode Guard Time AT S154 Software Version Information ATATI9CRLF Centre Radio Frequency AT S155Rssi Level Level at RF Input dBm ±2dB Radio Channel AT S157 Data Quality AT S158Squelch AT S159 Squelch Level Level at RF InputTransmission Power AT S160 Output Power for 1W G-MAX Output Power for 2W G-MAXPower Level Output Power DBm Tolerance Nominal Level NominalChannel Step Size AT S161 Test Message Period AT S162Over-Air Symbol Rate AT S163 Note engineering function only Preamble Period AT S165 Note engineering function onlyInvert Symbol AT S167 Frame Synch Tolerance AT S166 Note engineering function onlySquelch Delay AT S168 Restore defaults AT &Y8 Radio Frequency AT &FSave parameters AT &W AT &WCRLFDisplay parameters ATT? ATT?CRLFDo not enter unless you wish to carry out a code load Ppppppppppppppppppppppppppppppppppppppppppppppppppppp Hardware Specification RS232 Port ParametersRadio Specifications Parameter Max SXn50Mechanical Specification EnclosuresFront View of Casting Vibration Specifications Operating conditionsType Approvals EMC