4.21Squelch Delay (AT S168)

Note: engineering function only.

This command changes the delay between the Squelch being received and the FX929 modem IC looking for preamble in the receive audio. This allows the modem to be used with different transceivers. The command format is as follows:

 

AT S168=n<CR><LF>

Where:

n = 1 - 255 (ms)

Default:

n = 10

Read

AT S168?<CR><LF>

Read Return:

nnn<CR><LF>

Example:

AT S168=10<CR><LF> 10ms delay between squelch

 

and preamble

4.22Enable/Disable Receive Output Data (AT &D) This command disables output of any received data.

Note that the CD output continues to operate when the data output is disabled. The command is of the format:

 

AT &D=n<CR><LF>

 

Where:

n=0 disable output

 

 

n=1 enable output

 

Default:

n=1 (enabled)

 

Read:

AT &D?<CR><LF>

 

Read Return:

n<CR><LF>

 

Example:

AT &D=1<CR><LF>

enables receiver data output

4.23Enable/Disable Input Echo Data (AT &E)

This command enables/disables input echo on the screen. The command is of the format:

 

AT &E=n<CR><LF>

 

Where:

n=0 disable echo

 

 

n=1 enable echo

 

Default:

n=1 (enabled)

 

Read:

AT &E?<CR><LF>

 

Read Return:

n<CR><LF>

 

Example:

AT &E=1<CR><LF>

enables echo input

Hermes Operator Note

Page 23 of 32

Image 23
Contents Tel +44 0 118 981 Fax +44 0 118 981 Specialist RF DesignsLattice House Baughurst Basingstoke UK RG26 5LP Handshaking Operation During Transmit and Receive Table Of ContentsReceived Signal Strength Indication Rssi AT S156 List of Tables List of FiguresIntroduction Pin No Function RS232 ConnectorConnections & Indications Front Panel Indications Power ConnectorRF Connector Introduction Modem OperationReceive-to-Transmit Turnround Data Transfer ModesRS232 Data Handling MAX Time msDescription Okcrlf List of CommandsCommand Mode Errorcrlf Command SyntaxParity ATB1 Baud Rate AT B0AT F?CRLF Format Mode AT FRXX, Dxxxcrlf Engineering Test Modes ATOK Crlf Centre Radio Frequency AT S155 Command Mode Guard Time AT S154Software Version Information AT ATI9CRLFRssi Level Level at RF Input dBm ±2dB Data Quality AT S158 Radio Channel AT S157Squelch Level Level at RF Input Squelch AT S159Level Nominal Transmission Power AT S160Output Power for 1W G-MAX Output Power for 2W G-MAX Power Level Output Power DBm Tolerance NominalTest Message Period AT S162 Channel Step Size AT S161Preamble Period AT S165 Note engineering function only Over-Air Symbol Rate AT S163 Note engineering function onlyFrame Synch Tolerance AT S166 Note engineering function only Invert Symbol AT S167Squelch Delay AT S168 AT &WCRLF Restore defaults AT &Y8Radio Frequency AT &F Save parameters AT &WATT?CRLF Display parameters ATT?Do not enter unless you wish to carry out a code load Ppppppppppppppppppppppppppppppppppppppppppppppppppppp RS232 Port Parameters Hardware SpecificationParameter Max SXn50 Radio SpecificationsEnclosures Mechanical SpecificationFront View of Casting EMC Vibration SpecificationsOperating conditions Type Approvals