Jenn-Air 1892, 1300 manual Time ms, Description, Max

Page 9

Figure 1 Timing Information

 

 

 

 

 

 

Time (ms)

Function

Description

 

 

G-MAX

SXn50

 

 

(9600 baud)

(19200 baud)

t1

DTR input-to-modem DSR output

<90

<90

 

 

 

 

t2

RTS input to CTS output

<0.5

<0.5

 

 

 

 

t3

CTS output to Data input

>0.1

>0.1

 

 

 

 

t4

Data input to RF output (non-FEC mode)

<25

<25

 

 

 

 

 

Data input to RF output (FEC mode)

<25

<25

 

 

 

 

t5

RF output to CD output (at RX end)

<5

<2.5

 

 

 

 

t6

CD output to data output (non-FEC mode)

<30

<30

 

 

 

 

 

CD output to data output (FEC mode)

<50

<45

 

 

 

 

t7

Data input to Data output (non-FEC mode)

<50

<45

 

 

 

 

 

Data input to Data output (FEC mode)

<75

<55

 

Table 3 Timing Data

 

 

Hermes Operator Note

Page 9 of 32

Image 9
Contents Specialist RF Designs Lattice House Baughurst Basingstoke UK RG26 5LPTel +44 0 118 981 Fax +44 0 118 981 Table Of Contents Received Signal Strength Indication Rssi AT S156Handshaking Operation During Transmit and Receive List of Tables List of FiguresIntroduction RS232 Connector Connections & IndicationsPin No Function Power Connector RF ConnectorFront Panel Indications Introduction Modem OperationData Transfer Modes RS232 Data HandlingReceive-to-Transmit Turnround Time ms DescriptionMAX List of Commands Command ModeOkcrlf Errorcrlf Command SyntaxParity ATB1 Baud Rate AT B0AT F?CRLF Format Mode AT FEngineering Test Modes AT OK CrlfRXX, Dxxxcrlf Software Version Information AT Command Mode Guard Time AT S154ATI9CRLF Centre Radio Frequency AT S155Rssi Level Level at RF Input dBm ±2dB Data Quality AT S158 Radio Channel AT S157Squelch Level Level at RF Input Squelch AT S159Output Power for 1W G-MAX Output Power for 2W G-MAX Transmission Power AT S160Power Level Output Power DBm Tolerance Nominal Level NominalTest Message Period AT S162 Channel Step Size AT S161Preamble Period AT S165 Note engineering function only Over-Air Symbol Rate AT S163 Note engineering function onlyFrame Synch Tolerance AT S166 Note engineering function only Invert Symbol AT S167Squelch Delay AT S168 Radio Frequency AT &F Restore defaults AT &Y8Save parameters AT &W AT &WCRLFATT?CRLF Display parameters ATT?Do not enter unless you wish to carry out a code load Ppppppppppppppppppppppppppppppppppppppppppppppppppppp RS232 Port Parameters Hardware SpecificationParameter Max SXn50 Radio SpecificationsEnclosures Mechanical SpecificationFront View of Casting Operating conditions Vibration SpecificationsType Approvals EMC