4.28Code Loader (AT S2000)

Warning

once activated, a code load must be carried out

 

DO NOT enter unless you wish to carry out a code load

This command enables the firmware contained within the modem to be upgraded using a simple terminal program. The baud rate for the link is fixed at 19,200 baud with no parity.

The command for this is:

AT S2000<CR><LF>

The modem responds with:

Flash Programmer:"karfl3", Ver.:1.00.03, Date:24/10/2001

To update firmware, upload Hermes upgrade *.hex file using

a terminal program that can send 8 bit binary data.

Hermes®, © 2001, Wood & Douglas Ltd.

When this message has been output the code loader software is ready for the new code data to be uploaded. As each line of code is accepted the modem responds with one of 4 responses:

“.”

line written into program memory successfully

“:”

line written into EEPROM memory successfully

“P”

attempt to write into protected memory area, no action taken

“E”

error in writing to memory area

Hermes Operator Note

Page 26 of 32

Image 26
Contents Tel +44 0 118 981 Fax +44 0 118 981 Specialist RF DesignsLattice House Baughurst Basingstoke UK RG26 5LP Handshaking Operation During Transmit and Receive Table Of ContentsReceived Signal Strength Indication Rssi AT S156 List of Figures List of TablesIntroduction Pin No Function RS232 ConnectorConnections & Indications Front Panel Indications Power ConnectorRF Connector Modem Operation IntroductionReceive-to-Transmit Turnround Data Transfer ModesRS232 Data Handling MAX Time msDescription Okcrlf List of CommandsCommand Mode Command Syntax ErrorcrlfBaud Rate AT B0 Parity ATB1Format Mode AT F AT F?CRLFRXX, Dxxxcrlf Engineering Test Modes ATOK Crlf ATI9CRLF Command Mode Guard Time AT S154Software Version Information AT Centre Radio Frequency AT S155Rssi Level Level at RF Input dBm ±2dB Radio Channel AT S157 Data Quality AT S158Squelch AT S159 Squelch Level Level at RF InputPower Level Output Power DBm Tolerance Nominal Transmission Power AT S160Output Power for 1W G-MAX Output Power for 2W G-MAX Level NominalChannel Step Size AT S161 Test Message Period AT S162Over-Air Symbol Rate AT S163 Note engineering function only Preamble Period AT S165 Note engineering function onlyInvert Symbol AT S167 Frame Synch Tolerance AT S166 Note engineering function onlySquelch Delay AT S168 Save parameters AT &W Restore defaults AT &Y8Radio Frequency AT &F AT &WCRLFDisplay parameters ATT? ATT?CRLFDo not enter unless you wish to carry out a code load Ppppppppppppppppppppppppppppppppppppppppppppppppppppp Hardware Specification RS232 Port ParametersRadio Specifications Parameter Max SXn50Mechanical Specification EnclosuresFront View of Casting Type Approvals Vibration SpecificationsOperating conditions EMC