Jenn-Air 1300, 1892 manual Baud Rate AT B0, Parity ATB1

Page 12

4.3Baud Rate (AT B0)

When the baud rate is changed, the change is made after the Command Mode is ended (with the AT O command).

The baud rate is set with the following command:

Baud Rate

AT B0=n <CR><LF>

 

Where:

n = 1

4800

 

 

n = 2

9600

 

 

n = 3

19200

 

 

n = 4

38400

 

Default:

n = 3 for 12.5kHz radios

 

n = 4 for 25kHz radios

 

Read:

AT B0?<CR><LF>

 

Note:

this shows the new value, even though the change is

 

not implemented until the Command Mode is exited.

Read Return:

n<CR><LF>

 

Example:

AT B0=2<CR><LF>

for 9600 baud

4.4Parity (ATB1)

The number of data bits is fixed to 8. Parity at the RS232 input to the transmitter has no effect and is not transmitted. The 8 data bits can be used to transmit 7 data bits + 1 parity bit. In this case the modem has to be set to no parity.

The number of stop bits at the RS232 input to the transmitter can be 1 or more. The number of stop bits at the receiver RS232 output is fixed at 1. This is to avoid congestion of the output data.

When the parity is changed, the change is made after Command Mode is ended (with the AT O command).

The parity is set with the following command:

Parity

AT B1=n<CR><LF>

Where:

n = 1

even

 

n = 2

odd

 

n = 3

none

Default:

3

 

Read:

AT B1?<CR><LF>

Note:

this shows the new value, even though the change is

 

not implemented until the Command Mode is exited.

Read Return:

n<CR><LF>

Example:

AT B1=n<CR><LF>

Hermes Operator Note

Page 12 of 32

Image 12
Contents Specialist RF Designs Lattice House Baughurst Basingstoke UK RG26 5LPTel +44 0 118 981 Fax +44 0 118 981 Table Of Contents Received Signal Strength Indication Rssi AT S156Handshaking Operation During Transmit and Receive List of Figures List of TablesIntroduction RS232 Connector Connections & IndicationsPin No Function Power Connector RF ConnectorFront Panel Indications Modem Operation IntroductionData Transfer Modes RS232 Data HandlingReceive-to-Transmit Turnround Time ms DescriptionMAX List of Commands Command ModeOkcrlf Command Syntax ErrorcrlfBaud Rate AT B0 Parity ATB1Format Mode AT F AT F?CRLFEngineering Test Modes AT OK CrlfRXX, Dxxxcrlf Command Mode Guard Time AT S154 Software Version Information ATATI9CRLF Centre Radio Frequency AT S155Rssi Level Level at RF Input dBm ±2dB Radio Channel AT S157 Data Quality AT S158Squelch AT S159 Squelch Level Level at RF InputTransmission Power AT S160 Output Power for 1W G-MAX Output Power for 2W G-MAXPower Level Output Power DBm Tolerance Nominal Level NominalChannel Step Size AT S161 Test Message Period AT S162Over-Air Symbol Rate AT S163 Note engineering function only Preamble Period AT S165 Note engineering function onlyInvert Symbol AT S167 Frame Synch Tolerance AT S166 Note engineering function onlySquelch Delay AT S168 Restore defaults AT &Y8 Radio Frequency AT &FSave parameters AT &W AT &WCRLFDisplay parameters ATT? ATT?CRLFDo not enter unless you wish to carry out a code load Ppppppppppppppppppppppppppppppppppppppppppppppppppppp Hardware Specification RS232 Port ParametersRadio Specifications Parameter Max SXn50Mechanical Specification EnclosuresFront View of Casting Vibration Specifications Operating conditionsType Approvals EMC