Black Box LB1351A, LB1350A manual Management control menu, Broadcast protection

Page 31

Black Box®LB1350A/LB1351A

Choosing to set the broadcast protection mode will prompt the user for the desired setting (figure 6-12).

Broadcast protection:

1.Allow 25% broadcast frames

2.Allow 12% broadcast frames

3.Allow 6% broadcast frames

4.Allow 3% broadcast frames

0.Skip without changing Select (0-4):

figure 6-12 – broadcast protection mode select

If you wish to change the DSCP codes or the 802.1p priority classification you will be prompted for the DSCP code or priority code and the corresponding value, as shown in figures 6-13 and 6-14, respectively.

DSCP configuration:

Select DSCP code (0-63) or 64 to skip: 28

Select hi(1) or low(0) priority for DSCP 28: 1

figure 6-13 – DSCP configuration change

802.1p user priority classification: Select priority code (0-7) or 8 to skip: 3

Select hi(1) or low(0) priority for priority 3: 1

figure 6-14 – 802.1p priority classification change

Choosing the last option (8) of the advanced device control menu will cause the device to return to its default settings and restart. This may require a few seconds to complete. The default values are given in the status section. It is recommended to reset the device after this operation.

Management control menu

The management control menu (figure 6-15) provides the same options as other advanced port priority menus. These settings apply to in-bound and out-bound management traffic going through the ‘virtual management port’. Consider them as if they apply the same way as they do with any other port.

Management control:

===================

1.Enable/Disable tag insertion

2.Enable/Disable tag stripping

3.Set VLAN ID

4.Enable/Disable priority

5.Enable/Disable 802.1p priority

6.Enable/Disable TOS priority

7.Set user priority

0.Back to port control menu Select (0-7):

figure 6-15 – management control menu

Note that changing some settings (such as the VLAN ID) may cause management traffic to be stopped, thus disconnecting the management station from the device.

Please note that the VLAN related features (namely, tagging options) would take effect when the VLAN mode is ‘enabled’.

31

Image 31
Contents User and Installation Guide FCC Statement Instrucciones DE Seguridad Table of contents Overview Black BoxLB1350A/LB1351A Contents of the Shipping Container LB1350A-SC Product General DescriptionGeneral Description Black BoxLB1350A/LB1351A Comments Parts IdentificationPower Connection InstallationTwisted Pair Cable Connection Fiber Optic ConnectionFunction Up Position Down Comments Configuration SwitchesAdvanced Features Port Priority Schemes Troubleshooting Down Specifications Preface Setting Up Management ParametersManagement parameters setup screen Console parameters Network parametersSnmp parameters Network Connection Configuring the Management StationManaging the Black Box LB1351A Main menu Managing with a TerminalBasic status Device’s advanced status consists Advanced statusDevice control Device control menuBasic port control Port control menusTP port 1 basic control Advanced port controlAdvanced device control Basic device controlBroadcast protection Management control menuManaging with Snmp Basic device configurationSystem info Advanced device configuration Advanced device configurationUser priority configuration Basic port configurationSnmp traps Advanced port configurationTraps listed in bottom of screen Probable Cause TroubleshootingEuropean Union Declaration of Conformity