Xerox Nuvera® 100/120/144 EA Digital Production System - Customer Expectations Document
Product Space & Power Requirements
Item |
| Xerox Nuvera® 100/120/144 EA | Comments | |
|
| Digital Production System |
| |
Size – Printer w/ 1 SFM |
| 132” (W) X 29 ” (D) X 61.6 ” (H) |
| |
/ Scanner & MFF |
| 3353 mm x 737 mm x 1565 mm |
| |
Size – Printer w/ 1 SFM |
| 125” (W) X 29 ” (D) X 61.6 ” (H) | Printer Digital Tower 61.6” (1565 mm) (Height) | |
& SEM / FTM |
| 3175 mm x 737 mm x 1565 mm | DFA finishing devices vary by device*. | |
Size – Printer w/ 1 SFM |
| 124” (W) X 29 ” (D) X 61.6 ” (H) |
| |
& SEM / BFM |
| 3150 mm x 737 mm x 1565 mm |
| |
Width of additional |
| 31.7”, 805mm |
| Optional |
SFM |
|
|
|
|
Width of BFM Plus |
| 49”, 1233mm | Optional, BFM Plus and Interface Module used with BFM (with top | |
|
|
|
| tray) in dual BFM installations. |
Service Space |
| Fixed: 163” (W) x 112” (D) |
| - Fixed (stationary) installation: rear of the system should be at least |
(MFF Config.) |
| ( 4140mm x 2839mm) |
| 30” from the wall, machine, or rear obstruction.. |
|
| Moveable: 163” (W) x 92” (D) |
| - Moveable installation: rear of the system should be at least 10” from |
|
| ( 4140mm x 2336.8mm) |
| the wall and must be on mobility plates OR hard surface floor AND |
|
|
|
| with no more than 4 modules including MFF and MFF Interface |
|
|
|
| Module. |
Service Space |
| BFM: 145” (W) x 112” (D) | At least 30” from the wall in rear. | |
(BFM / FTM Config. |
| 3683mm x 2839 mm | DFA finishing will increase width - FTM config. dimensions do not | |
with SEM) |
| FTM: 143” (W) x 112” (D) | include DFA Finisher(s) dimensions or service space. | |
|
| 3632mm x 2839 mm |
| |
Weight |
| 1,753 lb. (795.2 kg) |
| With consumables loaded, except media |
(MFF Config. w/ |
| Additional SFM – 423 lbs. (192 kg) |
|
|
scanner) |
|
|
|
|
Weight |
| BFM: 1763 lb. (800 kg) |
| With consumables loaded, except media |
(BFM / FTM Config. |
| FTM: 1713 lb. (777 kg) |
| FTM config. listing does not include DFA Finisher(s) weight. |
with SEM) |
| Additional SFM – 423 lbs. (192 kg) |
|
|
Power Requirements |
| 187 – 240 Volts AC (Nominal), 50 Amp , |
| • UL & cUL compliant |
North America / Japan |
| 50/60 Hz wall service |
| • Complies with the FEMP (Federal Energy Management Program) |
(MFF / BFM Finishing) |
| Note – FTM and DFA finishers will require |
| via the machine circuit breaker (CB); with the CB switched off, the |
|
|
| system consumes less than 1 watt. | |
|
| additional power |
| • Energy Star (eStar) compliant** |
|
|
|
| • Environmental Choice (Canada)** |
|
|
|
| • Complies with Section 508 of the ADA Rehabilitation Act |
Power Requirements |
| 187 – 240 Volts AC (Nominal), 30 Amp + | • Units are compliant with applicable EU directives and are CE | |
Europe / |
| 20 Amp (2) , 50/60 Hz wall service | marked | |
|
| Feeders and Finisher modules (BFMs) will |
| |
|
| need additional 187 – 240 VAC (Nominal), |
| |
|
| 20 Amp, 50/60 Hz wall service |
| |
|
| Note – FTM and DFA finishers will require |
| |
|
| additional power |
|
*- Please refer to supported inline DFA finishing devices Solution Planning Guides for Product Space and Power Requirements.
**- the following configuration is not Energy Star compliant:
•100 ppm