Belkin F6C1000-EUR, F6C700-EUR, F6C1400-EUR Load Level Display, Battery Level Display

Page 16

P73335u_UPS_man.qxd

4/30/01 12:19 PM Page 12

Operation (continued)

4-6 Load Level Display

The 4-LED load percentage display shows the power level (20%, 40%, 60%, 80%) drawn by the loads from the UPS. If the UPS is overloaded, the OVERLOAD LED will light.

4-7 Battery Level Display

This display shows the battery capacity left in the battery. The level is represented by percentages of 25, 50, 75, and 100. These LED will extinguish gradually when using battery power. When battery capacity reaches the minimal level of 25%, the lowest LED (25%) blinks and there is an immediate need to charge the battery. Under this condition, the battery can only supply less than five minutes of run time for the load.

4-8 If certain abnormal conditions occur, the UPS will send the following messages:

ON BATTERY MODE: When the UPS is in ON BATTERY MODE, the ON BATTERY LED will light, preceded by a beep every two seconds, and then the UPS will start supplying power to the load through the battery.

12

Image 16
Contents UPS P73335uUPSman.qxd 30/01 1219 PM Language Table of Contents Table of Contents Important Safety Instructions TUV Safety InstructionSafety Instructions Symbols IntroductionBlock Diagram of Line Interactive UPS Theory of OperationAnnotation Front Panel Rear Panel Introduction Installation Before InstallationInstallation UnpackingInstallation Operation Battery Level Display Load Level DisplayOverload Battery ReplaceBUCK/BOOST Battery LOW Short CircuitOver Temperature UPS FaultMaintenance Replacing BatteryBattery Replacement Procedures Black Black 1000VA 700VA Red + Push back to UPS Troubleshooting Problem Possible Cause SolutionBUCK, Boost Communication Interface Parity None Cabling Computer UPS HardwareGND Low Battery Specifications BatteryElectrical Input Electrical OutputInterface MechanicalPhysical ApprovalAppendix a Typical Run Time Information FCC StatementBelkin Components Table des matières P73335f-UPS-man.qxd 30/01 1222 PM Consignes de sécurité importantes Consignes de sécurité TUVConsignes de sécurité suite Déclaration de conformité ECSymboles Introduction suite Théorie de fonctionnementCommentaire Face avant Face arrière Face arrière du modèle F6C700-EUR Avant de commencer linstallation DéballageInstallation suite Fonctionnement Affichage du niveau de charge Fonctionnement suiteAffichage du niveau des batteries Overload Surcharge Battery Replace Remplacer LA BatterieBUCK/BOOST BAISSE/HAUSSE DE Tension Battery LOW Batterie Faible Short Circuit COURT-CIRCUITOver Temperature Temperature Excessive UPS Fault Dysfonctionnement DE LonduleurRemplacement de la batterie Procédure de remplacement des batteries Remplacement de la batterie suiteAvertissement Noir 1000VA 700VA Rouge + Dépannage « ON/TEST »Dépannage suite Remplacer LAInterface de communication Interface de communication suite MaterielLongueur DES Donnees BIT DarretBatterie faible Mise hors tension Panne CA Spécifications Alimentation DentreePuissance EN Sortie BatterieSpécifications suite MecaniquePhysique CertificationAnnexe a Fonctionnement normal Information Belkin Components Inhaltsverzeichnis Abschnitt SeiteP73335g-UPS-man.qxd 30/01 1224 PM Wichtige Sicherheitshinweise TÜV-SicherheitshinweiseSicherheitsvorschriften Forts Symbole EinführungEinführung Forts FunktionsbeschreibungKonventionen Vorderseite Rückseite Rückseite F6C700-EUR Vor der Installation Auspacken des GerätsInstallation Fortsetzung Bedienung Bedienung Fortsetzung LastanzeigeBatterieladezustand Bei Unregelmäßigkeiten gibt die USV folgende Meldungen ausBedienung Fortsetzung Bedienung Fortsetzung Bedienung Fortsetzung Pflege und Wartung BatteriewechselHinweis Batteriewechsel FortsVorgehensweise zum Wechseln der Batterien Schwarz 700VA Rot + 1000VA USV einlegen Fehlerbehebung Fehler Mögliche Ursache LösungNORMAL, on Battery Fehlerbehebung FortsSerielle Schnittstelle Serielle Schnittstelle Forts StopbitKeine Verkabelung Computer USV ErdeSignal Erde Netzeingang Technische DatenStromausgang Technische Daten Forts Anhang a Typische Laufzeit FCC Behauptung Belkin Components