36 | 3M™ |
Description: This is the default mode of operation at power up. Touch reports include touchdown and liftoff events as well as continuing touches.
Name Command
Syntax: <SOH>NM<CR>
Response: | <SOH>0<CR> Positive response. |
Description: Returns a name string
Null Command
Syntax: | <SOH>Z<CR> |
Response: | <SOH>0<CR> Positive response. |
Description: | Queries the controller and waits for a response. |
| Use Z to determine that you are communicating with the controller or to make sure that a |
| utility is communicating with the controller. Using this command does not affect the |
| controller’s current operating parameters. |
Output Identity
Syntax: | <SOH>OI<CR> | |
Response: | <SOH>ADXxxx<CR> | |
| where: |
|
| AD | = Two ASCII characters that describe the type of 3M Touch Systems controller. |
| Xxxx | = This is a unique identifier not necessarily the actual firmware revision |
|
| number. |
Description: | Returns a | |
| version number. . |
Soft Reset
Syntax: | <SOH>R<CR> |
Response: | <SOH>0<CR> Positive response. |
Description: | Initializes the hardware and the firmware, causes the controller to stop sending data, and |
| recalculates the environmental conditions (for example, stray and offset values). The |
| Reset command also cancels the Calibrate command and returns the controller to normal |
| operation. |