IBM 71455DU manual Select Memory Settings Select Memory Mirroring Settings

Page 46

The following notes describe the Active Memory features:

vMemory mirroring enables you to improve the reliability of the memory in your server by creating a mirror of the data in memory port 1 and storing it in memory port 2.

Note: For memory mirroring to work, you must have DIMMs of the same size and clock speed in both memory ports.

Complete the following steps to enable memory mirroring:

1.Check your operating system documentation to make sure that it supports memory mirroring.

2.Install DIMMs of the same size and clock speed in the two memory ports.

3.Enable memory mirroring in the Configuration/Setup Utility program:

a.Turn on the server and watch the monitor screen.

b.When the message Press F1 for Configuration/Setup appears, press F1.

c.From the Configuration/Setup Utility main menu, select Advanced Setup.

d.Select Memory Settings.

e.Select Memory Mirroring Settings.

f.Enable the memory mirroring setting from within this window.

g.Save and exit the Configuration/Setup Utility program.

When memory mirroring is enabled, the data that is written to memory is stored in two locations. One copy is kept in the memory port 1 DIMMs, while a second copy is kept in the memory port 2 DIMMs. During the execution of the read command, the data is read from the DIMM with the least number of reported memory errors through memory scrubbing, which is enabled with memory mirroring.

If memory scrubbing determines that a DIMM is damaged beyond use, read and write operations are redirected to the remaining good DIMMs. Memory scrubbing then reports the damaged DIMM and light path diagnostics displays the error.

After the damaged DIMM is replaced, memory mirroring then copies the mirrored data back into the new DIMM.

vMemory scrubbing is an automatic daily test of all the system memory that detects and reports memory errors that might be developing before they cause a server outage.

Note: Memory scrubbing and Memory ProteXion technology work with each other and do not require memory mirroring to be enabled to work.

When an error is detected, memory scrubbing determines whether the error is recoverable. If it is recoverable, Memory ProteXion is enabled and the data that was stored in the damaged locations is rewritten to a new location. The error is then reported so that preventive maintenance can be performed. Provided that there are enough good locations to enable the correct operation of the server, no further action is taken other than recording the error in the error logs.

If the error is not recoverable, memory scrubbing sends an error message to light path diagnostics, which lights LEDs to guide you to the damaged DIMM. If memory mirroring is enabled, the mirrored copy of the data in the mirrored DIMM is used to refresh the new DIMM after it is installed.

vMemory ProteXion reassigns memory bits to new locations within memory when recoverable errors have been detected.

34IBM System x3950 Type 8878 and System x3950 E Type 8879: User’s Guide

Image 46
Contents User’s Guide Page User’s Guide Page Contents Page Safety Page To Connect To Disconnect Do not ≥ 18 kg 39.7 lb ≥ 32 kg 70.5 lb ≥ 55 kg 121.2 lb Page System x3950 and System x3950 E server Related documentationProblem Determination and Service Guide Features and specifications Features and specifications What your server offers Redundant cooling and power capabilities Light path diagnosticsPowerExecutive Redundant connection Integrated network supportReliability, availability, and serviceability UpdateXpress program IBM DirectorServer controls, connectors, LEDs, and power Front viewPage Rear view Server power features Turning on the server Turning off the serverPage Installing options Server componentsBoard internal connectors and jumpers Jumper name DescriptionMemory-card connectors Memory-card LEDsMicroprocessor-board connectors and LEDs PCI-X board connectors PCI-X board LEDsSAS-backplane connectors Installation guidelines Working inside the server with the power on System reliability guidelinesHandling static-sensitive devices Removing the cover and bezelInstalling a hot-swap power supply Locking latch Locking handle open Installing an adapter ServeRAID-8i adapter ServeRAID-8i slot LED Adapter guide Installing a hot-swap hard disk drive Installing options Memory module Memory card order Dimm pairActive Memory Select Memory Settings Select Memory Mirroring Settings Adding a memory card Adding and replacing a memory cardHot-replacing a memory card Installing DIMMs Installing a DimmDcac Hot-swapping DIMMs Installing options Hot-adding DIMMs Dimm Microprocessor Microprocessor installation order Installing a microprocessor Air baffle Heat sink Microprocessor connector Microprocessor- release lever Completing the installation Rear view Connecting the cablesFront view Two-node configuration Updating the server configurationSMP Expansion cabling Four-node configuration Protective cover Eight-node configuration Node SMP Expansion cable Page Installing options Page Gigabit Ethernet controller configuration process Configuration/Setup Utility programBoot Menu program SAS/SATA Configuration Utility programStarting the Configuration/Setup Utility program Using the Configuration/Setup Utility programConfiguration/Setup Utility menu choices System Card Data Power-on PasswordAdministrator Password Devices and I/O PortsRSA II Settings Advanced SetupMemory Settings System Partition VisibilityBMC Serial Port Access Mode Baseboard management controller BMC settingsBMC Post Watchdog Timeout Reboot system on NMIPasswords Power-on passwordUsing the ServerGuide Setup and Installation CD Administrator passwordServerGuide features Setup and configuration overviewUsing the Boot Menu program Typical operating-system installationInstalling your operating system without ServerGuide Download section, click Downloads & driversStarting the PXE boot agent utility program Configuring the Gigabit Ethernet controllerUsing the PXE boot agent utility program PXE boot agent utility menu choicesCommand-line interface Ipmi Shell Banner Message TimeoutPre-boot Wake on LAN Link SpeedUpdating and configuring the Bios Configuring Linux Configuring Red Hat Enterprise Linux ESOriginal /etc/lilo.conf contents Add the following five lines between the two title= sections Original /boot/grub/grub.conf contents Suse Sles 8.0 configuration Append the following text to the first title line Configuring a Microsoft Windows operating system Original bootcfg program outputInstalling the OSA SMBridge management utility program Modified bootcfg program outputUsing the baseboard management controller utility programs Using the OSA SMBridge management utility program Using ServeRAID Manager Using the SAS/SATA Configuration Utility programStarting the SAS/SATA Configuration Utility program SerialSelect Utility menu choicesUsing custom configuration Configuring the controllerUsing express configuration Click Express configurationUsing the Scalable Partition Web Interface Viewing the configurationCreating a scalable partition Page Configuring the server Page Deleting a scalable partition Page Updating IBM Director Page Appendix. Notices TrademarksImportant notes Product recycling and disposal Page Index LED SAS Memory-mirroring configuration Page Part Number 31R1871