Select this choice to specify the key strokes to start the PXE boot agent utility.

You can select Ctrl+S (default), or Ctrl+B.

vBanner Message Timeout

Select this choice to specify the amount of time (in seconds) that the server will wait for you to press Ctrl+S after the prompt appears. You can select 2 (default), 3, 5, or 8 seconds.

vLink Speed

Select this choice to set the link speed for the LAN connection. AutoNeg (auto-negotiate) is the default setting.

vPre-boot Wake on LAN

Select this choice to enable or disable the pre-boot Wake on LAN feature. Enable is the default setting

If you are using an Advanced Configuration and Power Interface (ACPI) aware operating system, such as Microsoft Windows 2000, disable this choice to use Wake on LAN support. Otherwise, enable it.

If you are using a non-ACPI-aware operating system, do not send wake-up packets to the server while it is turned on. If you send a wake-up packet to the server while it is turned on and you are then unable to turn off the server, see “Power problems” in the Problem Determination and Service Guide on the IBM System x Documentation CD.

Installing and using the baseboard management controller utility programs

The baseboard management controller provides environmental monitoring for the server. If environmental conditions exceed thresholds or if system components fail, the baseboard management controller lights LEDs to help you diagnose the problem and also records the error in the BMC system event log.

The baseboard management controller also provides the following remote server management capabilities through the OSA SMBridge management utility program:

vCommand-line interface (IPMI Shell)

The command-line interface provides direct access to server management functions through the IPMI 2.0 protocol. Use the command-line interface to issue commands to control the server power, view system information, and identify the server. You can also save one or more commands as a text file and run the file as a script.

vSerial over LAN

Establish a Serial over LAN (SOL) connection to manage servers from a remote location. You can remotely view and change the BIOS settings, restart the server, identify the server, and perform other management functions. Any standard Telnet client application can access the SOL connection.

Note: The server Ethernet ports are set to DHCP by default. The BMC MAC address can be found on a tag on the front of the server. Once you have deployed the server, remove the tag so that it does not impede airflow through the front of the server.

For more information about IPMI 2.0, see the Intelligent Platform Management

Interface Specification (IPMI Specification), version 2.0, available at

http://www.intel.com.

Chapter 3. Configuring the server 67

Image 79
Contents User’s Guide Page User’s Guide Page Contents Page Safety Page To Connect To Disconnect Do not ≥ 18 kg 39.7 lb ≥ 32 kg 70.5 lb ≥ 55 kg 121.2 lb Page Related documentation System x3950 and System x3950 E serverProblem Determination and Service Guide Features and specifications Features and specifications What your server offers Integrated network support Light path diagnosticsPowerExecutive Redundant connection Redundant cooling and power capabilitiesReliability, availability, and serviceability IBM Director UpdateXpress programFront view Server controls, connectors, LEDs, and powerPage Rear view Server power features Turning off the server Turning on the serverPage Server components Installing optionsJumper name Description Board internal connectors and jumpersMemory-card LEDs Memory-card connectorsMicroprocessor-board connectors and LEDs PCI-X board LEDs PCI-X board connectorsSAS-backplane connectors Installation guidelines System reliability guidelines Working inside the server with the power onRemoving the cover and bezel Handling static-sensitive devicesInstalling a hot-swap power supply Locking latch Locking handle open Installing an adapter ServeRAID-8i adapter ServeRAID-8i slot LED Adapter guide Installing a hot-swap hard disk drive Installing options Memory card order Dimm pair Memory moduleActive Memory Select Memory Settings Select Memory Mirroring Settings Adding a memory card Adding and replacing a memory cardHot-replacing a memory card Installing a Dimm Installing DIMMsDcac Hot-swapping DIMMs Installing options Hot-adding DIMMs Dimm Microprocessor Microprocessor installation order Installing a microprocessor Air baffle Heat sink Microprocessor connector Microprocessor- release lever Completing the installation Rear view Connecting the cablesFront view Two-node configuration Updating the server configurationSMP Expansion cabling Four-node configuration Protective cover Eight-node configuration Node SMP Expansion cable Page Installing options Page SAS/SATA Configuration Utility program Configuration/Setup Utility programBoot Menu program Gigabit Ethernet controller configuration processStarting the Configuration/Setup Utility program Using the Configuration/Setup Utility programConfiguration/Setup Utility menu choices Devices and I/O Ports Power-on PasswordAdministrator Password System Card DataSystem Partition Visibility Advanced SetupMemory Settings RSA II SettingsReboot system on NMI Baseboard management controller BMC settingsBMC Post Watchdog Timeout BMC Serial Port Access ModePower-on password PasswordsAdministrator password Using the ServerGuide Setup and Installation CDSetup and configuration overview ServerGuide featuresDownload section, click Downloads & drivers Typical operating-system installationInstalling your operating system without ServerGuide Using the Boot Menu programPXE boot agent utility menu choices Configuring the Gigabit Ethernet controllerUsing the PXE boot agent utility program Starting the PXE boot agent utility programLink Speed Banner Message TimeoutPre-boot Wake on LAN Command-line interface Ipmi ShellUpdating and configuring the Bios Configuring Red Hat Enterprise Linux ES Configuring LinuxOriginal /etc/lilo.conf contents Add the following five lines between the two title= sections Original /boot/grub/grub.conf contents Suse Sles 8.0 configuration Append the following text to the first title line Original bootcfg program output Configuring a Microsoft Windows operating systemModified bootcfg program output Installing the OSA SMBridge management utility programUsing the baseboard management controller utility programs Using the OSA SMBridge management utility program SerialSelect Utility menu choices Using the SAS/SATA Configuration Utility programStarting the SAS/SATA Configuration Utility program Using ServeRAID ManagerClick Express configuration Configuring the controllerUsing express configuration Using custom configurationUsing the Scalable Partition Web Interface Viewing the configurationCreating a scalable partition Page Configuring the server Page Deleting a scalable partition Page Updating IBM Director Page Trademarks Appendix. NoticesImportant notes Product recycling and disposal Page Index LED SAS Memory-mirroring configuration Page Part Number 31R1871