Table 4. Alternate memory card installation sequence (continued)

Memory card order

Memory card

DIMM pair

 

 

 

Fourth

4

1 and 3

 

 

 

 

 

2 and 4

 

 

 

Table 5. Memory card installation sequence for memory-mirrored configuration

Memory card order

Memory card

DIMM pair

 

 

 

First

1

1 and 3

 

 

 

 

3

1 and 3

 

 

 

Second

2

1 and 3

 

 

 

 

4

1 and 3

 

 

 

Third

1

2 and 4

 

 

 

 

3

2 and 4

 

 

 

Fourth

2

2 and 4

 

 

 

 

4

2 and 4

 

 

 

vThere are two memory power buses split between the four memory cards. Memory cards 1 and 2 are on power bus 1, and memory cards 3 and 4 are on power bus 2. If memory mirroring is enabled, you can hot-replace one memory card at a time on each memory power bus.

vIf a problem with a DIMM is detected, light path diagnostics will light the system-error LED on the front of the server, indicating that there is a problem and guide you to the defective DIMM. When this occurs, first identify the defective DIMM; then, remove and replace the DIMM.

The following illustration shows the LEDs on the memory card:

Memory Port Power

Error

Memory Hot-Swap Enabled

Memory Hot-Swap Enabled LED: When this LED is lit, it indicates that hot-swap memory is enabled.

Error LED: When this LED is lit, it indicates that a memory card or DIMM has failed.

Memory Port Power LED: When this LED is off, it indicates that power is removed from the port and that you can remove the memory card and replace a failed DIMM. This LED will also turn off when the release levers are opened.

Note: Add odd numbered DIMMs to each available memory card first, then add the even numbered pairs.

Active Memory

Active Memory is an IBM technology that improves the reliability of the DIMMs through the memory mirroring, memory scrubbing, and Memory ProteXionfeatures.

Chapter 2. Installing options 33

Image 45
Contents User’s Guide Page User’s Guide Page Contents Page Safety Page To Connect To Disconnect Do not ≥ 18 kg 39.7 lb ≥ 32 kg 70.5 lb ≥ 55 kg 121.2 lb Page Related documentation System x3950 and System x3950 E serverProblem Determination and Service Guide Features and specifications Features and specifications What your server offers PowerExecutive Redundant connection Light path diagnosticsRedundant cooling and power capabilities Integrated network supportReliability, availability, and serviceability IBM Director UpdateXpress programFront view Server controls, connectors, LEDs, and powerPage Rear view Server power features Turning off the server Turning on the serverPage Server components Installing optionsJumper name Description Board internal connectors and jumpersMemory-card LEDs Memory-card connectorsMicroprocessor-board connectors and LEDs PCI-X board LEDs PCI-X board connectorsSAS-backplane connectors Installation guidelines System reliability guidelines Working inside the server with the power onRemoving the cover and bezel Handling static-sensitive devicesInstalling a hot-swap power supply Locking latch Locking handle open Installing an adapter ServeRAID-8i adapter ServeRAID-8i slot LED Adapter guide Installing a hot-swap hard disk drive Installing options Memory card order Dimm pair Memory moduleActive Memory Select Memory Settings Select Memory Mirroring Settings Adding and replacing a memory card Adding a memory cardHot-replacing a memory card Installing a Dimm Installing DIMMsDcac Hot-swapping DIMMs Installing options Hot-adding DIMMs Dimm Microprocessor Microprocessor installation order Installing a microprocessor Air baffle Heat sink Microprocessor connector Microprocessor- release lever Completing the installation Connecting the cables Rear viewFront view Updating the server configuration Two-node configurationSMP Expansion cabling Four-node configuration Protective cover Eight-node configuration Node SMP Expansion cable Page Installing options Page Boot Menu program Configuration/Setup Utility programGigabit Ethernet controller configuration process SAS/SATA Configuration Utility programUsing the Configuration/Setup Utility program Starting the Configuration/Setup Utility programConfiguration/Setup Utility menu choices Administrator Password Power-on PasswordSystem Card Data Devices and I/O PortsMemory Settings Advanced SetupRSA II Settings System Partition VisibilityBMC Post Watchdog Timeout Baseboard management controller BMC settingsBMC Serial Port Access Mode Reboot system on NMIPower-on password PasswordsAdministrator password Using the ServerGuide Setup and Installation CDSetup and configuration overview ServerGuide featuresInstalling your operating system without ServerGuide Typical operating-system installationUsing the Boot Menu program Download section, click Downloads & driversUsing the PXE boot agent utility program Configuring the Gigabit Ethernet controllerStarting the PXE boot agent utility program PXE boot agent utility menu choicesPre-boot Wake on LAN Banner Message TimeoutCommand-line interface Ipmi Shell Link SpeedUpdating and configuring the Bios Configuring Red Hat Enterprise Linux ES Configuring LinuxOriginal /etc/lilo.conf contents Add the following five lines between the two title= sections Original /boot/grub/grub.conf contents Suse Sles 8.0 configuration Append the following text to the first title line Original bootcfg program output Configuring a Microsoft Windows operating systemModified bootcfg program output Installing the OSA SMBridge management utility programUsing the baseboard management controller utility programs Using the OSA SMBridge management utility program Starting the SAS/SATA Configuration Utility program Using the SAS/SATA Configuration Utility programUsing ServeRAID Manager SerialSelect Utility menu choicesUsing express configuration Configuring the controllerUsing custom configuration Click Express configurationViewing the configuration Using the Scalable Partition Web InterfaceCreating a scalable partition Page Configuring the server Page Deleting a scalable partition Page Updating IBM Director Page Trademarks Appendix. NoticesImportant notes Product recycling and disposal Page Index LED SAS Memory-mirroring configuration Page Part Number 31R1871