This book is part of the RS/6000® SPhardware service library and applies to the RS/6000 SP Switch. Use this book to assist you in performing the following tasks:

vIdentify field replaceable unit (FRU) locations

vIsolate RS/6000 SP failures using Maintenance Analysis Procedures (MAPs)

vPerform diagnostic service procedures

vPerform removal and replacement procedures

vIdentify FRUs and their corresponding part numbers

If you are attempting to isolate an SP system failure, use the Maintenance Analysis Procedures (MAPs) beginning with the Start MAP in RS/6000 SP: System Service Guide (GA22-7442). For a listing of the complete RS/6000 SP hardware service library, see ªRelated informationº.

Who should use this book

This book is intended for RS/6000 SP product-trained service personnel.

Related information

The following books make up the complete RS/6000 SP hardware service library:

vRS/6000 SP: Safety Information, GA22-7467. Safety notices, in English and translated into other national languages, which are compiled from all the book in the library.

vRS/6000 SP: Installation and Relocation, GA22-7441. Installation and relocation procedures, maintenance agreement and qualification procedures, frame and component identification information.

vRS/6000 SP: System Service Guide, GA22-7442. General SP system service procedures, the system Start MAP, and MAPs and parts catalog for the frames and power subsystems. Use this book to begin a diagnostic procedure to isolate a problem to a specific major component of the SP system.

vRS/6000 SP: SP Switch Service Guide, GA22-7443 (this book).

vRS/6000 SP: SP Switch2 Service Guide, GA22-7444. Service procedures, MAPs, and parts catalog information specific to the SP Switch2.

vRS/6000 SP: Uniprocessor Thin and Wide Node Service Guide, GA22-7445. Service procedures, MAPs, and parts catalog information specific to all uniprocessor-type nodes.

vRS/6000 SP: 604 and 604e SMP High Node Service Guide, GA22-7446. Service procedures, MAPs, and parts catalog information specific to these nodes.

vRS/6000 SP: SMP Thin and Wide Node Service Guide, GA22-7447. Service procedures, MAPs, and parts catalog information specific to these nodes.

vRS/6000 SP: POWER3 SMP High Node Service Guide, GA22-7448. Service procedures, MAPs, and parts catalog information specific to this node.

This book and other RS/6000 SP hardware and software documentation are available both on-line and, for some books, in printed form from the following sources:

vThe Web site at http://www.ibm.com/servers/eserver/pseries/library/sp_books/index.html

vThe Resource Center on the PSSP product media

vPrinted and CD-ROM versions (which can be ordered from IBM)

For more information on these sources and an extensive listing of RS/6000 SP related publications, see the bibliography in RS/6000 SP: Installation and Relocation.

© Copyright IBM Corp. 1999, 2002

xv

Image 17
Contents IBM Page IBM Fifth Edition April Contents FRU removals and replacements Figures Vi RS/6000 SP SP Switch Service Guide Vii TablesViii RS/6000 SP SP Switch Service Guide Safety notices Safety and environmental noticesRS/6000 SP SP Switch Service Guide SPSFD017 Xii RS/6000 SP SP Switch Service Guide Environmental notices Product recycling and disposal Laser safety informationXiv RS/6000 SP SP Switch Service Guide Related information About this bookWho should use this book How to send your comments Summary of changes Xviii RS/6000 SP SP Switch Service Guide Maintenance Analysis Procedures MAPs Switch description and problem determination MAP Flashing Power GreenEnvironment Yellow Priority Message or condition Action Errors in /var/adm/SPlogs/css/out.top seeCondition Action SP Switch environment MAPSwitch connector resistance values Step Priority Component Action SP Switch inner chassis and front chassis cablesStep 10RS/6000 SP SP Switch Service Guide Step 12RS/6000 SP SP Switch Service Guide SP Switch power MAP SP Switch power MAP PDU-BH-P1 PDU-BH-P2 PDU-BH-P3 PDU-BH-P4 PDU-BH-P5 From P1 pin FromEprimary SP Switch function MAPEstart Pg /var/adm/SPlogs/css/out.top Notes Splstdata -n pgSP Switch function MAP If the cabling does not match, correct the cabling Error # Message/condition Description and actionSplstdata -s pg SDRGetObjects DependentNodeE02-S00-BH-J18 L01-S00-BH-J18L03-N01 E02-N04Var/adm/SPlogs/css/out.top file have Priority Message/condition ActionStep Failing components Description Service Request NumberSRN 26RS/6000 SP SP Switch Service Guide Priority Failing component Action 28RS/6000 SP SP Switch Service Guide Step 30RS/6000 SP SP Switch Service Guide Estart Do not perform the cable wrap test Step Do not perform cable wrap test Step Check /var/adm/SPlogs/css/out.top file Format structure LocationsNaming standard for RS/6000 SP components Major assembly Location diagrams of the RS/6000 SP componentsFigure notes Front and rear views of RS/6000 SP frame2shows a front view of the RS/6000 SP multi-switch frame Front view of 49-inch frame locations. See notes below Frame FRA Frame locationsExample E01-FRA-G1 Air Baffle Switch assembly locationsCable routing Connector details10RS/6000 SP SP Switch Service Guide Cable routing in a multi-switch frame F/C 2030/1 12RS/6000 SP SP Switch Service Guide Cable Part Plug from Plug to Number Location Switch data cables14RS/6000 SP SP Switch Service Guide Tools and files overview Service proceduresPersonal ESD requirements Rc.switch Utility see note Runs on Description FaultserviceWormRTGIfconfig File see note Location Description Rc.switch.logUsing the css.snap script Verification tests using Perspectives Switch supervisor self-testNode supervisor verification Self-test Conditions Pass sequenceFrame supervisor verification Switch supervisor verificationSelecting the switch clock source Selecting appropriate switch clocksDetermining the correct switch clock source EclockNumber of Logical Master Clock Choice Model Frames Removing and restoring switch resourcesRemoving a switch assembly from the active configuration Viewing switch partitions Restoring a switch assembly to the active configurationEfence of primary and primary backup nodes Replacing a switch assembly from service positionResetting the clock and bootlist after servicing a node Installing adapter microcode packages Installing firmware updates on SP nodesAdapter Package Running diagnostics on a switch port Handling static-sensitive devices FRU removals and replacementsReplacing the switch assembly Procedures for switch assembliesRemoving the switch assembly Removing the switch front chassis cable Removing the switch fansReplacing the switch fans Removing the switch supervisor card Replacing the switch front chassis cableRemoving the switch inner chassis cable Replacing the switch supervisor cardRemoving the switch power cards Replacing the switch inner chassis cableRemoving the SP Switch power supply cards Replacing the switch power cards8RS/6000 SP SP Switch Service Guide Parts catalog SPS, SPS-8 Switch assembly feature view Assembly Part number Units Description Index 4RS/6000 SP SP Switch Service Guide Inner chassis assembly SPS includes all assembly in shaded Air flow Cable, front chassis SP Switch External Cables SPS SPS-8 Switch cables featureSP Switch Data Cables SPS-8 Parts catalog Multi-switch frame F/C 2030/1 Multi-switch frame F/C 2030/1 12RS/6000 SP SP Switch Service Guide Trademarks Industry Canada compliance statement United Kingdom telecommunications safety requirementsEuropean Union EU statement Radio protection for Germany For installations in JapanElectromagnetic interference EMI statement Taiwan 4RS/6000 SP SP Switch Service Guide Index Numerics ESD Switch inner chassis cable, SPS Switch partitioning 4RS/6000 SP SP Switch Service Guide Please tell us how we can improve this book Readers comments ± Wed like to hear from youHow satisfied are you that the information in this book is IBM Page IBM
Related manuals
Manual 108 pages 26.79 Kb

RS/6000 SP specifications

The IBM RS/6000 SP (Scalable Power) is a high-performance computing system that was developed in the early 1990s and has since become a significant player in the realm of supercomputing and enterprise solutions. Designed primarily for scientific, engineering, and complex data analysis tasks, the RS/6000 SP provides powerful processing capabilities, enhanced scalability, and features to support demanding applications.

One of the key characteristics of the RS/6000 SP is its modular architecture, which allows for the addition of multiple nodes. Each node is based on IBM's Power architecture, leveraging the RISC (Reduced Instruction Set Computing) design to achieve high throughput and efficiency. The system can support configurations ranging from a few nodes to hundreds, enabling organizations to scale their computational power as needed based on workload requirements.

The RS/6000 SP employs advanced interconnect technologies, most notably the SP Switch, which ensures high-speed communication between nodes. This interconnect allows for seamless data transfer, ensuring that the system can handle large datasets and complex computations without bottlenecks. The SP's ability to deliver concurrent processing capabilities makes it ideal for parallel computing tasks, including simulations, modeling, and large-scale computations.

In terms of software, the RS/6000 SP was equipped with AIX, IBM's version of the UNIX operating system, which provides a stable and secure environment for enterprise applications. Furthermore, the system supports a vast array of programming languages and tools, including Fortran, C, and C++, along with libraries and frameworks designed for high-performance computing. This compatibility allows developers to optimize their applications to fully utilize the underlying hardware.

Another notable feature of the RS/6000 SP is its extensive support for various workloads, including database management, multi-user applications, and graphical processing. The system was equipped with high-performance graphics capabilities, making it suitable for tasks that require intensive visualization, such as computer-aided design (CAD) and scientific visualization.

Overall, the IBM RS/6000 SP has solidified its role in the high-performance computing landscape, combining advanced technologies, robust scalability, and flexibility to meet the unique demands of research and enterprise environments. Its legacy continues to influence modern computing architectures, embodying IBM’s commitment to innovation and performance in the pursuit of complex problem-solving capabilities.