Xantrex Technology GT Series Installing the Ethernet Communications Kit, Panel with Four M6 Nuts

Page 17

Installation

Installing the Ethernet Communications Kit

You will have to make connections to the CCU control board inside of the enclosure. Use caution not to discharge any static electricity onto the control board.

Use the following procedure to install the new Ethernet

Communications Kit:

1. Install the panel with the four M6 nuts.

M6 Nuts

Figure 1 Panel with Four M6 Nuts

2.Connect the fiber optic cable to the RS232/Fiber adapter.

3.Connect the orange cable to the TX connector on the RS232/Fiber adapter.

4.Connect the blue cable to the RX connector on the RS232/Fiber adapter. See Figure 2.

153553

3

For use by qualified technicians only

Image 17
Contents GT Series Three Phase Ethernet Communications Kit Page GT Series Three Phase Ethernet Communications Kit Date and Revision Purpose About This GuideScope Audience OrganizationRelated Information Conventions UsedSave These Instructions do not Discard Important Safety InstructionsRisks Personal Safety General Safety PrecautionsSafety Equipment Qualified PersonnelLockout and Tag Operational Safety ProceduresPV Terminals TB3, TB4, and TB5 PV GND Intended Use De-Energize/Isolation ProcedureInterconnection Standards Compliance Contents Xii Interface Requirements Installation and ConfigurationEquipment Required InstallationDe-Energize/Isolation Procedure Shutdown Panel with Four M6 Nuts Installing the Ethernet Communications KitEthernet Kit Cable Connections LAN Interface Set-up ConfiguringEnergize Procedure Startup Ethernet Communications Kit Configuration Diagram Configuring the LAN InterfaceWarranty Warranty and Return InformationDisclaimer Warranty and ReturnExclusions Return Material Authorization PolicyReturn Procedure Out of Warranty Service Page Xantrex Technology Inc