Xantrex Technology GPIB-XPD manual Bit Decimal Description Reset By Position Weight, Lsb, Msb

Page 34

Operation

GPIB Operation

Serial Poll In a serial poll, the controller polls each device.

Example:

ibrsp

Return serial poll byte.

The power supply responds with a 8-bit status byte defined as follows:

Table 3.2 Serial Poll Status Register

Bit

Decimal

Description

Reset By

Position

Weight

 

 

0

(LSB)

1

Fault - Set when any bit in the fault

FAULT? query to reset

 

 

 

register is set by a fault condition in the

 

 

 

 

supply. See also “Accumulated

 

 

 

 

Status, Status, and Fault Registers”

 

 

 

 

on page 46.

 

1

 

2

Not used

 

 

 

 

 

 

2

 

4

Not used

 

 

 

 

 

 

3

 

8

Not used

 

 

 

 

 

 

4

 

16

Ready - Set when power supply is

Power supply, during

 

 

 

ready to accept commands.

command processing

 

 

 

 

period

5

 

32

Error (ERR) - Set when ERR bit

ERR? query

 

 

 

asserted in status register. See also

 

 

 

 

“Accumulated Status, Status, and

 

 

 

 

Fault Registers” on page 46.

 

6

 

64

Request Service (SRQ) - Set when

Serial Poll

 

 

 

power supply requests service.

 

7

(MSB)

128

Power On (PON) - Set when unit

CLR or Device Clear

 

 

 

initializes at power on.

 

32

Operating Manual for GPIB for XPD Series Power Supply

Image 34
Contents GPIB-XPD Page Internal Gpib Interface for XPD 500 Watt Series How do you get service? Phone 604 422 Toll Free North America 800 667 Fax 604 421What does this warranty not cover? Disclaimer Product Information About Your Power Supply Model Number Serial Number Purchased From Purchase DateSafety SupplyMain Sections Installation and ConfigurationManual Revisions About This Manual Contents Contents Features and Specifications DescriptionFunctions Features and FunctionsFeatures and Specifications ReadbackModels 18-30 33-16 60-9 120-4.5 SpecificationsOVP Features and Specifications Introduction Initial InspectionPower Supply Front Panel with Gpib Interface Installed Gpib Interface Subplate Located on Power Supply Rear Panel Gpib Interface PCB Step # Description Action Reference Basic Setup ProcedurePON SRQ IEEE-488 Primary Address Selection AddressRear Panel SRQ Switch Position PON SRQ State Power On Service Request PON SRQSwitch Position Power on results Condition Default Settings Model Example IsetIEEE-488 Controller Connection Internal PCB Jumper SelectionsOVP Control Mode Selection High OFF LOW User SignalsHigh LOW OFF User Signals J21 Connector J21 User Signal Connector Circuit Block Diagram J21 User Cable with Ferrite Block Operation Gpib OperationExample Command directed to entire bus, or Power On PON Set when unit Bit Decimal Description Reset By Position WeightRequest Service SRQ Set when LSBComputer Entry Command SyntaxFormat Description Form Floating Number Definition ExampleIset 2.0A Vset Command Summary CMODE? AUXA?AUXB? DLY?Idata FAULT?Cmode IHIAuxa 1 on Command ReferenceCommand Description Auxb 1 onChanging an output setting Response Fold mode where mode is Snsp Mask None = Unmask ALLStatus, and Fault Registers on Accumulated Status, Status, and Fault Registers on SNSP, ALL, NoneResponse Vmax voltage Accumulated Status, Status, and Fault Registers Condition Mnemonic Bit Position Bit WeightError Codes 11 Error CodesTroubleshooting LEDsCalibration Voltage Program Calibration Procedure Readback Voltage Mode CalibrationSetup VoltageCalibration Current Calibration Setup Current Mode CalibrationCurrent Program Calibration Procedure Current Readback Calibration Procedure Over Voltage Protection OVP Calibration Page Xantrex Technology Inc