Xantrex Technology GPIB-XPD manual Command Syntax, Computer Entry, Format

Page 35

Operation

Command Syntax

Command Syntax

Manual The manual uses these conventions when displaying command information. These Conventions characters are not part of the command but are used to denote parameters used with

the command.

< > (angle brackets)

Angle brackets enclose a parameter. Do not include

 

the angle brackets in the command line you send to

 

the computer.

/ (slash)

Separates two alternative parameters. When a slash

 

separates two parameters, you can use either

 

parameter to achieve the same result.

 

Example: <1/ON>

 

Entering 1 or ON will achieve the same result.

COMPUTER ENTRY

Words typed on the computer are shown in Arial

 

text, full capitals.

Command The device-dependent language for the GPIB Interface consists of commands and Format and parameters. A command is a one word code which either gives instructions to the Parameters interface or asks for information from the interface. A command may be followed by

one or more parameters, a short code that changes the state of the power supply or the state of the bit register. Table 3.3, “Command Parameters” lists the parameters that affect the command set.

Format:

COMMAND or

COMMAND <parameter> or

COMMAND <parameter>,<parameter>

You can enter commands in upper or lower case lettering.

Example:

MASK FOLD = mask fold

Do not further abbreviate command names or parameters.

Example:

MASK FOLD MK FOLD

 

MASK FOLD MASK FD

Use a space between the command and the first parameter. Any number of consecutive spaces is treated as one space. Numeric data may contain leading spaces. Embedded spaces between digits or between a digit and a decimal point are not accepted.

Example:

MASK FOLD = MASK

FOLD

 

VOUT 3.4

= VOUT

3.4

 

VOUT 3.4

VOUT 3.

4

Release 1.2

33

Image 35
Contents GPIB-XPD Page Internal Gpib Interface for XPD 500 Watt Series Phone 604 422 Toll Free North America 800 667 Fax 604 421 How do you get service?What does this warranty not cover? Disclaimer Product Model Number Serial Number Purchased From Purchase Date Information About Your Power SupplySupply SafetyManual Revisions Installation and ConfigurationMain Sections About This Manual Contents Contents Description Features and SpecificationsReadback Features and FunctionsFeatures and Specifications FunctionsOVP SpecificationsModels 18-30 33-16 60-9 120-4.5 Features and Specifications Initial Inspection IntroductionPower Supply Front Panel with Gpib Interface Installed Gpib Interface Subplate Located on Power Supply Rear Panel Gpib Interface PCB PON SRQ Basic Setup ProcedureStep # Description Action Reference Address IEEE-488 Primary Address SelectionSwitch Position Power on results Power On Service Request PON SRQRear Panel SRQ Switch Position PON SRQ State Iset Condition Default Settings Model ExampleInternal PCB Jumper Selections IEEE-488 Controller ConnectionOVP Control Mode Selection High LOW OFF User SignalsHigh OFF LOW User Signals J21 Connector J21 User Signal Connector Circuit Block Diagram J21 User Cable with Ferrite Block Gpib Operation OperationExample Command directed to entire bus, or LSB Bit Decimal Description Reset By Position WeightRequest Service SRQ Set when Power On PON Set when unitFormat Command SyntaxComputer Entry Floating Number Definition Example Description FormIset 2.0A Vset Command Summary DLY? AUXA?AUXB? CMODE?IHI FAULT?Cmode IdataAuxb 1 on Command ReferenceCommand Description Auxa 1 onChanging an output setting Response Fold mode where mode is Mask None = Unmask ALL SnspStatus, and Fault Registers on SNSP, ALL, None Accumulated Status, Status, and Fault Registers onResponse Vmax voltage Condition Mnemonic Bit Position Bit Weight Accumulated Status, Status, and Fault Registers11 Error Codes Error CodesLEDs TroubleshootingCalibration Voltage Voltage Mode CalibrationSetup Voltage Program Calibration Procedure ReadbackCalibration Current Program Calibration Procedure Current Mode CalibrationCurrent Calibration Setup Current Readback Calibration Procedure Over Voltage Protection OVP Calibration Page Xantrex Technology Inc