Xantrex Technology 18V 10A manual Specification, Output

Page 4

Specification

OUTPUT

Voltage Range:

0V to 18V minimum

Current Range:

0A to 10A minimum

Output Voltage Setting:

By coarse and fine controls.

Output Current Setting:

By single logarithmic control.

Operating Mode:

Constant voltage or constant current with automatic cross-over.

Output Switch:

Electronic. Preset voltage and current displayed when off.

Output Terminals:

4mm terminals on 19mm (0.75”) pitch.

Output Impedance:

Typically <5min constant voltage mode.

 

Typically >10kin constant current mode.

Output Protection:

Output will withstand up to 22V forward voltage.

 

Reverse protection by diode clamp for reverse currents up to 3A.

Load & Line Regulation:

<0.01% of maximum output for a 90% load change or 10% line

 

change.

Ripple & Noise

Typically <2mVrms, <10mV pk-pk, constant voltage mode.

(20MHz bandwidth):

 

Transient Response:

<200µs to within 50mV of set level for 90% load change.

Temperature Coefficient:

Typically <100ppm/°C

Status Indication:

Output on lamp. Constant current mode lamp.

METER SPECIFICATIONS

Meter Types:

Dual 4 digit meters with 14mm (0.56") LEDs. Reading rate 4 Hz.

Meter Resolutions:

10mV, 10mA

Meter Accuracies:

Voltage 0.3% of reading ± 2 digits

 

Current 0.6% of reading ± 2 digits

GENERAL

AC Input:

Factory set for: 110V - 120V AC ±10% or 220V - 240V AC ±10%,

 

50/60Hz. Installation Category II.

Power Consumption:

400VA max.

Operating Range:

+5ºC to +40ºC, 20% to 80% RH.

Storage Range:

40ºC to + 70ºC.

Environmental:

Indoor use at altitudes up to 2000m, Pollution Degree 2.

Safety:

Complies with EN610101.

EMC:

Complies with EN61326.

Size:

140 x 160 x 320mm (WxHxD).

Weight:

2.8kg

3

Image 4
Contents XPH Series 18V 10A DC Power Supply XPHPart Number Contact InformationTable of Contents IntroductionSpecification OutputSafety Emissions ImmunityInstallation ConnectionsMains Operating Voltage Mains LeadOperation Maintenance CleaningSeries or Parallel Connection with Other Outputs VentilationAccess to Calibration Adjustments CalibrationCurrent Calibration Voltage CalibrationVoltage Regulation Sécurité AVERTISSEMENT! CET Instrument Doit Etre Relie a LA TerreTension d’utilisation secteur ConnexionsCâble secteur Fonctionnement Fusible Connexion en série ou en parallèle avec d’autres sortiesNettoyage Sicherheit WARNUNG! Dieses Gerät Muss Geerdet WerdenNetzbetriebsspannung AnschlüsseNetzkabel Verbraucheranschluß BetriebIstwert-Fernerfassung Reihen- und Parallelschaltung mit anderen Ausgängen Sicherung WartungReinigung Sicurezza Attenzione Questo Strumento Deve Essere Collegato a TerraInstallazione CollegamentiTensione d’esercizio Cavo d’alimentazioneFunzionamento Manutenzione Collegamento in serie/parallelo con altre usciteVentilazione FusibileSeguridad ADVERTENCIA! Este Instrumento Debe Conectarse a TierraInstalación ConexionesTensión de la Red Eléctrica Cable de RedOperación Mantenimiento Conexión en Serie o en Paralelo a Otras SalidasVentilación LimpiezaWarranty Information How do you get service?What does this warranty not cover? ProductReturn Material Authorization Policy Xantrex Technology Inc